BlueField-3 Firmware Release Notes

Bug Fixes in This Version

Internal Ref.

Issue

4219027

Description: Fixed an issue where the BlueField-3 device, which uses two GPIOs for pkg_id calculation, had the MSB incorrectly set to zero.

Keywords: NC-SI package ID

Discovered in Version:

32.42.1000

Fixed in Release:

32.43.2402

4174096

Description: Fixed an issue that occasionally resulted in ext_synd = 0x8309 in dmesg when enabled the internal NP/DOCA NP.   

Keywords: PCC NP

Discovered in Version:

32.42.1000

Fixed in Release:

32.43.2402

3787618

Description: NVIA register is not allowed for external host if any field of EXTERNAL_HOST_PRIV or EXTERNAL_HOST_PRIV_FAST TLVs is not set as the default. 

Keywords:

Host privilege

Discovered in Version:

32.41.1000

Fixed in Release:

32.43.2402

3614288

Description: Occasionally, the device may hang when there a hot plug is performed from a unknown direction.

Keywords: Hot-plug operation

Discovered in Version:

32.39.2048

Fixed in Release:

32.43.2402

4030180

Description: Fixed an issue that prevented virtio 2K device from working with LFWP at the same time due to limited hardware resource. Therefore, resulting in LFWP command failure.

Keywords: virtio 2K, LFWP

Discovered in Version:

32.42.1000

Fixed in Release:

32.43.2402

Last updated: