NVIDIA BlueField BMC Software

Bug Fixes in This Version


For an archive of bug fixes from previous releases, please refer to Bug Fixes History.

Ref #

Issue Details

4398082

Description: On BlueField-3, repeatedly modifying the BMC user password can eventually fill the flash storage due to excessive log generation. This may cause the BMC logging service to enter an abnormal state.

Discovered in version: 24.10

4508657

Description: After upgrading the BMC to version 24.10 or later, SEL entries generated by earlier versions may no longer appear in ipmitool sel output.

Discovered in version: 24.10

4413916

Description: On certain BlueField-3 systems, newly created BMC users may fail to authenticate via ipmitool lanplus, returning an "unauthorized name" error.

Discovered in version: 24.10

4481392

Description: BMC reboot in the middle of config update can result in unexpected behavior.

Discovered in version: 24.10

4440343

Description: The BMC fails to boot due to the device running out of space, as the dump file completely filled the read-write flash.

Discovered in version: 24.10

4461233

Description: In BlueField-3 BMC, the USB interface between Arm and BMC could drop to full speed and fail to recover, causing sustained performance degradation.

Discovered in version: 24.10

4482812

Description: In BlueField-3 BMC software, the RTC battery sensor generates false SEL entries due to an incorrect or overly sensitive voltage threshold that misclassified normal readings as out of range.

Discovered in version: 24.10-LTSU2