For an archive of bug fixes from previous releases, please refer to Bug Fixes History.
|
Ref # |
Issue Details |
|---|---|
|
4976718 |
Description: If a BMC task such as a log dump is started after the BMC firmware update task has been initiated but before monitoring has attached to it, the monitoring logic may track the other task instead of the firmware update task, which can cause the BMC reboot to fail. |
|
Reported in version: 25.10-LTSU2 |
|
|
4917779 |
Description: Initiating an Arm GracefulReset can cause the BMC's Redfish UpdateService to incorrectly report its state as UnavailableOffline. |
|
Reported in version: 25.10-LTSU2 |
|
|
4944048 |
Description: When upgrading or downgrading between the 25.10-LTSU2 and 26.04 releases, repeated BMC reboots may, in rare cases, cause the |
|
Reported in version: 25.10-LTSU2 |
|
|
5096810 |
Description: The |
|
Reported in version: 25.10-LTSU2 |
|
|
5071650 |
Description: In rare cases, the EROT version string may contain space characters instead of the actual version characters, making the version appear partial. Rebooting the BMC reloads the string correctly. |
|
Reported in version: 25.10-LTSU2 |
|
|
5017603 |
Description: During BFB installations via Redfish, the task state may change to "Exception" before the specific error message is appended to the HTTP response payload. This results in incomplete error logs on the initial poll following a failure. |
|
Reported in version: 25.10-LTSU2 |
|
|
4994932 |
Description: In rare cases, the PLDM firmware update process in NIC mode may fail during the activation phase due to a transient communication error on the device. |
|
Reported in version: 25.10-LTSU2 |
|
|
4966479 |
Description: In rare cases, accessing the |
|
Reported in version: 25.10-LTSU2 |
|
|
5071627 |
Description: On some Aztlan BlueField-2 cards, the BMC may report false VCORE and 3P3V_AUX voltage warnings during normal operation. These false-positive warnings could appear in the system event log (SEL) and as warning sensor health in Redfish and IPMItool, triggering unnecessary alerts without indicating an actual hardware fault. This issue was fixed by adjusting the warning thresholds for the VCORE and 3P3V_AUX sensors to align with normal operating ranges. |
|
Reported in version: 25.10-LTSU2 |
|
|
5071048 |
Description: Enhanced the Arm-side port link status reporting to ensure accurate link status evaluations and prevent false configuration error alarms in the BMC SEL log during DPU OS reboots. |
|
Reported in version: 25.10-LTSU2 |
|
|
5071040 |
Description: Following a DPU reset, the |
|
Reported in version: 25.10-LTSU2 |
|
|
5030888 |
Description: When running |
|
Reported in version: 25.10-LTSU2 |
|
|
5030870 |
Description: Following a firmware update via the OobUpdate script, the version reported for components such as UEFI may occasionally fail to reflect the newly installed version. This is a transient reading error, not an update failure. |
|
Reported in version: 25.10-LTSU2 |
|
|
5030860 |
Description: In rare cases, after a firmware upgrade, |
|
Reported in version: 25.10-LTSU2 |
|
|
5017581 |
Description: When performing a BMC firmware update via |
|
Reported in version: 25.10-LTSU2 |
|
|
4970600 |
Description: Accumulated CPER (Common Platform Error Records) logs in |
|
Reported in version: 25.10-LTSU2 |
|
|
4966467 |
Description: Event log warnings for |
|
Reported in version: 25.10-LTSU2 |
|
|
4935831 |
Description: After deleting an entry in the BMC WebUI Event Log, the table may not immediately reflect the deletion. Reloading the page displays the correct updated log. |
|
Reported in version: 25.10-LTSU2 |
|
|
4885311 |
Description: In rare cases (approximately 1%), BMC sensors and SDR data may not be available within 2 minutes of a BMC reboot, due to additional initialization tasks introduced in recent versions. |
|
Reported in version: 25.10-LTSU2 |
Last updated: