Networking NVIDIA BlueField BMC Software

Known Issues

For known issues and limitations of the NVIDIA® BlueField® BSP, see BSP Known Issues.

Ref #

Issue Details

5393264

Description: The Redfish AddressOrigin value for oob0 (/redfish/v1/Systems/Bluefield/EthernetInterfaces/oob0) might show IPv4LinkLocal instead of DHCP, even when the interface gets its IPv4 address through DHCP. This issue is cosmetic and does not affect network connectivity.

Workaround: N/A

Reported in version: 26.10

5295459

Description: On BlueField-3, the Redfish Chassis.Reset action for Bluefield_DPU_IRoT and Bluefield_ERoT fails with ActionParameterNotSupported when ResetType is PowerCycle, even though ResetActionInfo lists PowerCycle as the only allowed value.

Workaround: To reset Bluefield_ERoT after you stage an ERoT firmware image, send a POST request to /redfish/v1/Chassis/Bluefield_ERoT/Actions/Chassis.Reset with {"ResetType": "GracefulRestart"}. Do not use the Redfish reset action on Bluefield_DPU_IRoT, because it reports success without resetting the IRoT.

Reported in version: 26.10

5302420

Description: On BlueField-3, the target path of the Redfish LogService.CollectDiagnosticData action for DebugTokenService omits the Actions path segment that the standard Redfish format uses (.../DebugTokenService/Actions/LogService.CollectDiagnosticData). This path is kept for backward compatibility.

Workaround: Send the LogService.CollectDiagnosticData POST request to /redfish/v1/Systems/Bluefield/LogServices/DebugTokenService/LogService.CollectDiagnosticData.

Reported in version: 26.10

5134017

Description: During doca-installer upgrade or downgrade flows, the BMC firmware update might intermittently fail with return code 202, and doca-installer might report that the 3-port switch is not responding. BMC or CEC versions might also appear as N/A in doca-installer, although they are available through Redfish. This is caused by a temporary communication issue between the BlueField and the BMC through the 3-port switch.

Workaround: Wait a few minutes for the connection between the BlueField and the BMC to recover, then rerun the update flow or the version validation.

Reported in version: 26.10

5234967

Description: On BlueField-2, a heavy load of certain IPMI commands might cause high CPU usage on the BMC because of hardware performance limitations. As a result, the BMC health monitor might generate CPU threshold alarms in the journal and event log.

Workaround: N/A

Reported in version: 26.10

5332103

Description: On BlueField-3, the Redfish Links.PhysicalPortAssignment property of a NetworkDeviceFunction resource links to a Port resource instead of a NetworkPort resource. Redfish clients or validators that check the linked resource type might report a mismatch.

Workaround: Use the @odata.type value of the linked resource (#Port.v1_6_0.Port) to identify its type.

Reported in version: 26.10

5039938

Description: During a BFB upgrade, the verification output might display a mismatch in the BMC firmware version strings. The offline target image reports the version normally (e.g., BF-26.04-7), but the pending post-upgrade version that the MISOC register returns might appear in a nonstandard format with extra leading zeros (e.g., BF-26.04-07 or 0260108). Because of this string difference, update tools like doca-installer might incorrectly report that the BMC update failed.

Workaround: Complete the update process by performing a full system power cycle.

Reported in version: 26.04

4944048

Description: When upgrading from or downgrading to 25.10-LTSU2, repeated BMC reboots might, in rare cases, cause the profile-manager service to fail due to a malformed JSON file. This failure triggers a core dump of the service, populates core dump logs, and causes the golden-image service to stop responding.

Workaround: Perform a factory reset on the BMC.

Reported in version: 25.10-LTSU2

4914053

Description: The BFB installer defaults to DHCP for the VLAN4040 interface. If no DHCP server is present, the request silently fails after a 300-second timeout, bypassing the static IP fallback and skipping all BMC-related firmware updates.

Workaround: Ensure a DHCP server is accessible during installation, or manually configure a static IP for the VLAN4040 interface to prevent the timeout. If you use the updated installer script, static IP is the default, and you must explicitly enable DHCP by using VLAN4040_DHCP_ENABLE in the bf.cfg file.

Reported in version: 26.04

4931912

Description: Running ipmitool sel clear when the BMC System Event Log (SEL) is at 100% capacity clears the log but does not record the expected Log area reset/cleared event entry.

Workaround: Clear the SEL before it reaches maximum capacity.

Reported in version: 26.04

4995031

Description: After a firmware update through the OobUpdate script, the version reported for components such as UEFI might occasionally not reflect the newly installed version. This is a transient reading error, not an update failure.

Workaround: Perform a system reboot to clear the transient state and ensure all components accurately report their updated versions.

Reported in version: 26.04

4994932

5086446

Description: In rare cases, the PLDM firmware update process in NIC mode might fail during the activation phase due to a transient communication error on the device.

Workaround: Reset the BMC and retry the PLDM firmware update.

Reported in version: 26.04

4882705

Description: The ENABLE_BMC_WAIT configuration requires a power cycle of the BlueField DPU to take effect and function properly. If you initiate a warm reboot of both the DPU Arm and the DPU BMC simultaneously, the system treats these as two separate, uncoordinated actions. As a result, the DPU Arm and UEFI do not wait for the BMC to become fully ready before proceeding with their own boot sequence.

Workaround: Always perform a full cold boot of the host server or issue a complete DPU power cycle instead of relying on independent warm reboots of the subsystems.

Reported in version: 26.01

4868713

Description: When a PLDM firmware update initiated from the host BMC is canceled or fails, the CEC firmware version might remain stuck in a pending state.

Workaround: Perform a full power cycle of the card (power off the host, run ipmitool power cycle from the DPU BMC, and then power the host back on). Alternatively, you can reset the CEC directly without a full power cycle by issuing a Redfish CEC self-reset command.

Reported in version: 26.01

4870597

Description: When upgrading the BlueField-2 BMC from an earlier version that lacks Redfish Host Interface support (e.g., 2.8.2-x) to a later version that includes this feature (version 23.10 or later), the Redfish communication channel between the BlueField BIOS and the BMC Redfish server fails to initialize automatically.

Workaround: Perform a BMC factory reset immediately following the firmware upgrade.

Reported in version: 26.01

4876483

Description: When upgrading the BlueField firmware bundle (e.g., from 3.1.0 to 3.3.0), the doca-installer post-installation verification might fail with return code 1. A cosmetic mismatch in the BMC version string causes this failure: the pending version includes a leading zero (e.g., BF-26.01-04), but the expected target version does not (e.g., BF-26.01-4).

Workaround: You can safely ignore this error. A standard system power cycle resolves the mismatch.

Reported in version: 26.01

4885282

Description: When enabling Livefish mode from the DPU-BMC using ipmitool, the command might return a timeout error. This response is erroneous; the DPU successfully transitions into Livefish mode despite the error message.

Workaround: N/A

Reported in version: 26.01

4857246

Description: The Redfish interface might list unsupported parameters (such as EROT, ROT, and FirmwareAttributes) under OEMDiagnosticDataType. If you attempt to collect diagnostic data using these unsupported types, the task remains in the Running state for approximately 45 minutes before it fails or is canceled.

Workaround: Use only the diagnostic dump types listed in this guide (typically BMC and System). Ignore unsupported values listed in the Redfish CollectDiagnosticDataActionInfo output.

Reported in version: 26.01

4662191

Description: The BMC pending version might be displayed in a nonstandard format (e.g., version BF-26.01-36 might appear as 02601036).

Workaround: N/A

Reported in version: 26.01

4850556

Description: Performing a power reset of the DPU through the DPU-BMC might result in partial IP address information being displayed in redfish/v1/Systems/Bluefield/EthernetInterfaces/. This issue is cosmetic and does not impact network functionality.

Workaround: Reboot the DPU-BMC to refresh and display the full IP address information.

Reported in version: 25.10

4877678

4240364

Description: Stress testing during upgrades and downgrades between BMC versions 25.01-1 and 24.10-17g might occasionally result in a loss of the BMC IP address.

Workaround: N/A

Reported in version: 25.10

4127100

Description: The BMC System Event Log (SEL) capacity calculation incorrectly excludes critical and warning events, counting only informational (debug) entries. As a result, the total number of SEL entries might exceed the configured maximum limit (e.g., exceeding a 600-entry limit), leading to inaccurate capacity reporting in tools like ipmitool sel info.

Workaround: Manually clear the SEL if it becomes too large.

Reported in version: 25.10

4502081

Description: When the BMC SEL is full or contains a large number of entries, the BMC might require more than 110 seconds to fully initialize the SDR, sensor, and FRU information after a reboot. In rare cases (1-2%), this delay might exceed expected timeouts, taking up to about 112 seconds.

Workaround: N/A

Reported in version: 25.10

4793060

Description: Downgrading the BlueField-3 firmware bundle through PLDM is not supported in BMC 25.10-LTSU1.

Workaround: N/A

Reported in version: 25.10

N/A

Description: The IP address range 192.168.240.0 to 192.168.240.7 is reserved for internal communication between the BMC and UEFI. User-configured TCP connections that use addresses in this range might be automatically terminated by the system.

Workaround: N/A

Reported in version: 25.10

4422284

Description: An eROT firmware update proceeds regardless of the ForceUpdate setting, including when the installed and target versions match.

Workaround: N/A

Reported in version: 25.10

4650613

Description: On BlueField-2 DPUs, the BMC might not switch to the updated firmware image after a host power cycle during upgrade. This occurs because the ERoT (CEC) resets during the cycle, preventing the BMC flash from activating the new image. The update becomes effective only after the BMC itself is rebooted.

Workaround: Reboot the BMC after the host power cycle to activate the new image.

Reported in version: 25.10

4336172

Description: Pushing a PLDM package update to the BMC/CEC without rebooting the host causes the update process to fail.

Workaround: N/A

Reported in version: 25.07

4560376

Description: Performing a BMC factory reset without following up with a graceful reset leaves the BMC in an incomplete transitional state, resulting in undefined system behavior.

Workaround: After you initiate a factory reset, perform a graceful reset to complete the process. If you skip the graceful reset, rerun the factory reset procedure and immediately follow it with a graceful reset.

Reported in version: 25.07

4029375

Description: The Redfish schema for /Systems/Bluefield/ResetActionInfo is not supported.

Workaround: N/A

Reported in version: 25.04

4284756

Description: The UEFI re-enables a boot option after a power reset of the DPU.

Workaround:

  1. Set the boot option enable attribute to false.

  2. Power reset the DPU.

  3. Do not reboot or power reset the DPU a second time. If the DPU is rebooted or power reset again, the boot option enable attribute reverts to true on UEFI-generated boot options. This issue does not affect legacy boot options.

  4. To prevent the UEFI from resetting boot options entirely, set SYS_DISABLE_AUTO_BOOT_REFRESH=TRUE in the bf.cfg file.

Reported in version: 25.01

4259780

Description: On BlueField-2, updating the BFB image over HTTPS without a CA fails and might not return the correct failure message.

Workaround: N/A

Reported in version: 25.01

4261446

Description: When the BlueField-2 SEL is full, loading the SEL database and initializing the log might take multiple attempts.

Workaround: Retry the dump generation command.

Reported in version: 25.01

4276783

Description: An orchestrated DPU-BMC reboot does not work after an upgrade if the CEC version has not changed.

Workaround: N/A

Reported in version: 25.01

4177391

Description: The BMC Redfish schema contains invalid attributes, which cause the Redfish Mockup Creator to return elements not found errors.

Workaround: N/A

Reported in version: 25.01

4243159

Description: The BMC dump collection is missing the procfd.log file.

Workaround: N/A

Reported in version: 25.01

4249132

Description: Copying a file that consumes space in the BMC root file system makes the BMC unusable after a reboot.

Workaround: Do not copy any files to the BMC. If you do, you must replace the BlueField-3.

Reported in version: 25.01

4178704

Description: When you delete an IPv4 or IPv6 static IP address through the Redfish interface, an unexpected failure message might appear even though the operation succeeded. Example for an IPv6 address:

redfish/v1/Managers/Bluefield_BMC/EthernetInterfaces/eth0 -d '{"IPv6StaticAddresses": [{"Address": "0000:0000:0000:0000::0000", "PrefixLength": 64}]}'

Workaround: N/A

Reported in version: 24.10-LTSU1

3922872

Description: In the Systems/Bluefield/LogServices/Dump/Entries Redfish schema, the Originator and OriginatorType fields do not persist after a BMC reboot.

Workaround: N/A

Reported in version: 24.10

4123370

Description: When the BMC does not own RShim, the error notification for a BFB update is unclear.

Workaround: N/A

Reported in version: 24.10

4048673

Description: The BMC does not update the AllowableValues in the response to a GET request for the Chassis/Bluefield_ERoT/ResetActionInfo schema.

Workaround: N/A

Reported in version: 24.10

4127461

Description: On BlueField-2, when the BMC comes up after a reboot and the SEL buffer is full, it takes about 30 seconds for the BMC to finish setting up all of the SEL entries. Until then, you cannot add entries or query existing ones.

Workaround: N/A

Reported in version: 24.10

N/A

Description: When a new host forces RShim ownership, ownership might become ambiguous, and the resulting conflict causes several BMC features to stop working.

Workaround: Reboot the BMC after moving RShim ownership to a new host. This ensures the BMC correctly synchronizes with the current RShim ownership status.

Reported in version: 24.07

3877835

Description: openbmctool is no longer supported.

Workaround: The supported management interfaces are ipmitool and Redfish.

Reported in version: 24.07

4027478

Description: The BMC IP aliasing feature lets you assign multiple IP addresses to a single network interface, so the interface can respond to different IP addresses.

Workaround: N/A

Reported in version: 24.07

3995907

Description: The Redfish schema for BlueField data ports (Systems/Bluefield/EthernetInterfaces) displays only the valid IP and MAC addresses. Ignore the other attributes in this schema because they are not current.

Workaround: N/A

Reported in version: 24.07

3899799

Description: The update to ipmitool version 1.8.19 introduced inconsistencies between the tool and the BMC implementation. As a result, the lan print command displays incomplete information.

Workaround: N/A

Reported in version: 24.07

3995899

Description: The DPU BMC detects ECC errors from the BlueField Arm system and records these errors in the BMC SEL. For SEL events related to single-bit ECC errors, the BMC does not recognize the resolution status on the BlueField Arm and consequently logs "Resolved": false regardless of the actual state.

Workaround: N/A

Reported in version: 24.07

3925815

Description: When you change the BMC IPv6 address configuration from static to DHCP, the static IP address in the IPv6 list is not disabled.

Workaround: N/A

Reported in version: 24.07

3899719

Description: After you run sel clear, the event log in LogServices generates Error.LogsCleared.

Workaround: N/A

Reported in version: 24.07

4005373

Description: The DPU BMC does not support the following attributes and schemas within the Systems/Bluefield Redfish schema: MemorySummary, Memory, Processors, Storage, GraphicalConsole, and PowerMode.

Workaround: N/A

Reported in version: 24.07

3995906

Description: The BlueField power cycle relies on the PCIe PERST/ALL_STANDBY. If the host does not disconnect the PCIe link, the DPU BMC cancels the power cycle request to avoid causing server errors. Because the power cycle command is asynchronous, it always returns success; however, if it fails, a new SEL entry is created to indicate that the command did not run.

Workaround: Get the status from the BMC SEL.

Reported in version: 24.07

3998661

Description: The ipmitool set static ip command deletes both the IPv4 and IPv6 addresses, creates an IPv4 static IP address, and then changes the IPv4 address, which generates one additional create event and one additional delete event.

Workaround: N/A

Reported in version: 24.07

3914629

Description: If you set "Force PXE" right before installing a BFB image through the BMC RShim, the BlueField PXE boot fails to boot from NET-OOB-IPV4.

Workaround: N/A

Reported in version: 24.04

4064373

Description: The DPU BMC LLDP represents the eth0 interface. If you create a VLAN interface on top of eth0, the LLDP schema does not function as expected, and the transmitted data does not accurately describe the eth0 attribute or the VLAN that you created.

Workaround: N/A

Reported in version: 24.04

3994990

Description: During a power cycle of the BlueField, the ipmb_host driver running on the BlueField OS might crash due to communication issues with the BlueField BMC, causing the BlueField OS to stop responding.

Workaround: Reboot or reset the BlueField again.

Reported in version: 24.01

3725502

Description: The BMC records user operations regardless of whether the action succeeds.

Workaround: N/A

Reported in version: 24.01

3598450

Description: The boot process might stall after a non-graceful reboot.

Workaround: Do not perform a forced reboot of the BlueField BMC.

Reported in version: 24.01

3664596

Description: If you configure only a secondary NTP server, that server acts as the primary server.

Workaround: N/A

Reported in version: 24.01

3747285

Description: The ipmitool command to force PXE in the BMC modifies both the IPMI and Redfish request settings. When Redfish is enabled in UEFI, Redfish takes priority, so all PXE boot entries are attempted before regular boot continues.

Workaround: If you need IPMI force PXE retry behavior, disable Redfish in UEFI.

Reported in version: 24.01

3662417

Description: The Arm UEFI is crucial for rapid system booting, activating the NIC for host network communication. The Arm UEFI tries to fetch Redfish host credentials from the DPU BMC during boot. If it does not get them within a designated timeframe, the UEFI skips Redfish setup and boots the OS, ignoring any Redfish server settings or updates.

Workaround: Reboot the BlueField Arm core again.

Reported in version: 24.01

3668925

Description: If you need to set up a VLAN for a specific interface on the BMC, finish all other network configuration (such as DHCP or static) on the interface before you configure the VLAN, because the VLAN inherits all configuration from the existing interface.

Workaround:

  1. Initialize the network interface:

    ipmitool lan set 1 ipsrc static
    ipmitool lan set 1 ipaddr <ip>
    ipmitool lan set 1 netmask <netmask>
    ipmitool lan set 1 defgw ipaddr <gateway-ip>
    
  2. Set the VLAN:

    ipmitool lan set 1 vlan id <vlan-id>
    

Reported in version: 23.10

3534150

Description: The BMC and BlueField use a shared IPMB channel for IPMI communication. If multiple requests coincide on this interface, you might encounter command failures with timeout indications.

Workaround: Raise the retry counter for ipmitool requests by using the ipmitool -R 20 * command.

Reported in version: 23.10

3631199

Description: If Redfish is enabled in the UEFI menu (default), then Secure Boot configuration done from Redfish overrides Secure Boot configurationFactory Reset BMCdone from UEFI.

Workaround: Disable Redfish in the UEFI menu, and then update the Secure Boot state.

Reported in version: 23.10

3654930

Description: If the BlueField BMC firmware has been upgraded from version 2.8.2-x or earlier to version 23.03 or later, you must perform a factory reset of the BlueField BMC.

Workaround: N/A

Reported in version: 23.03

3637527

Description: The BlueField Redfish BIOS (UEFI) supports only UEFI mode for BootSourceOverrideMode. If you set BootSourceOverrideMode to legacy, the BIOS (UEFI) ignores all override settings.

Workaround: Set BootSourceOverrideMode to UEFI.

Reported in version: 23.10

3634649

Description: In the Redfish Systems/Bluefield schema, the LastResetTime attribute does not accurately capture the system reset values.

Workaround: N/A

Reported in version: 23.09

3634603

Description: When the BlueField operates in NIC mode, the Arm core does not load any OS. In this scenario, any BMC functionality that relies on extracting data from the OS through the IPMB channel is unavailable or limited, including:

  • Firmware inventory schema

  • Chassis schema

  • Sensors

Workaround: N/A

Reported in version: 23.10

3609525

Description: After the BlueField BMC reboots, wait 30 seconds for all system services to load before you reboot the BlueField.

Workaround: N/A

Reported in version: 23.09

3590634

Description: When you update the BMC firmware, keep the system powered on until the update process finishes.

Workaround: N/A

Reported in version: 23.09

3599824

Description: In NIC mode, the BMC Redfish chassis schema contains only limited information about the BlueField because the OS is not available to supply the necessary information to the BMC.

Workaround: N/A

Reported in version: 23.09

3605254

Description: After a system power cycle, the BlueField and the BMC boot independently, so the BlueField UEFI boot process might finish before the BMC boot process. As a result, the BMC might not yet be ready to respond to Redfish communication attempts.

Workaround: Wait until the BMC is done booting before issuing a reset command to the DPU.

Reported in version: 23.09

3388059

Description: When BlueField-2 boots and loads its services, IPMI over RMCP might stop responding because the default command timeout is 1 second.

Workaround: Increase the default timeout to 10 seconds when sending IPMI RMCP commands using the -N option. Example command:

Bash
sudo ipmitool -I lanplus -C 17 -N 10 -H <BMC-IP> -U <BMC-User> -P <BMC-Password> mc info

Reported in version: N/A