NVIDIA UFM Cable Validation Tool

Bug Fixes in This Release


Ref #

Bug Fix

4916902



Description: Fixed an issue where Golden BER tests did not support multi-device switch configurations, including XDR InfiniBand switches and NVSwitches.

Keywords: Golden BER Test

Discovered in Release: v1.6.0

4647722



Description: Fixed an issue where Amber Collection tests on a single node incorrectly displayed a status of "Finished" while the test was still running.

Keywords: Amber collect test

Discovered in Release: v1.7.0

4937654



Description: Fixed an issue where transceiver EEPROM read errors were incorrectly reported when vendor information contained non-standard characters.

Keywords: Transceiver EEPROM

Discovered in Release: v1.8.1

4931766



Description: Fixed an issue where active InfiniBand ports on compute trays were incorrectly reported as "Media Unplugged."

Keywords: IB ports

Discovered in Release: v1.8.1

4930055

 

 

Description: Fixed an issue where Rx/Tx and BER counters were not updated for the first breakout port in 2x breakout configurations.

Keywords: BER counters, RX/TX, Breakout cable

Discovered in Release: v1.8.1

 4919088

 

 

Description: Fixed an issue where advanced statistics were not displayed for split /1 NVSwitch ports in CVT.

Keywords: BER counters, RX/TX, Breakout cable

Discovered in Release: v1.8.1

 4899790

 

 

Description: Fixed an issue where IP mapping files could not be loaded for topology or DOT files when navigating directly from Unified P2P.

Keywords: Load IP file, dot/topo file

Discovered in Release: v1.8.1

 4889379

 

 

Description: Fixed an issue that could result in an empty screen after a process shutdown.

Keywords: CVT service

Discovered in Release: v1.8.1

 4740810

 

 

Description: Add ability to catch errors when IP mapping file is wrong

Keywords: IP file

Discovered in Release: v1.8.1

 4877340

 

 

Description: Fixed an issue where invalid IP mapping files were not properly detected or reported.

Keywords: Filters

Discovered in Release: v1.8.1

4879158

 

 

Description: Fixed an issue where the output window size was restricted and could not be resized horizontally.

Keywords: output window, resize

Discovered in Release: v1.8.1

4893470

 

 

Description: Fixed an issue where an unnecessary horizontal scrollbar appeared in the Devices view when selecting the Circuits tab.

Keywords: Horizontal scroll

Discovered in Release: v1.8.1

4938052

 

 

Description: Fixed an issue where read-only users could not authenticate to specific CVT APIs used for NVSwitch management.

Keywords: NVSwitch, REST API

Discovered in Release: v1.8.1

4946732

 

 

Description: Fixed an issue where Circuit History database records accumulated indefinitely, causing excessive database growth.

Keywords: Circuit History Retension

Discovered in Release: v1.8.1

4921873

 

 

Description: Fixed an issue where compute trays in the GB200 36x2 rack were not allocated the correct 2U space in rack view.

Keywords: GB200 Rack View

Discovered in Release: v1.8.1

4656016

 

 

Description: Fixed an issue where the "BER Last Update Duration" field was empty in BER test results.

Keywords: Golden BER test

Discovered in Release: v1.7.0

4929507

 

 

Description: Fixed an issue where CVT displayed None/NA values for discovered Z nodes and ports following a switch reboot.

Keywords: Switch Reboot, Neighbor Discovery

Discovered in Release: v1.8.1

4949651

 

 

Description: Fixed an issue where user-hidden columns disappeared from the Display Columns list after a page refresh.

Keywords: Tables, Display Columns

Discovered in Release: v1.8.1

4828152

 

 

Description: Fixed an issue where Golden BER test files were not automatically cleared after six hours.

Keywords: Golden BER Test

Discovered in Release: v1.8.1

4952121

 

 

Description: Fixed an issue where the Device Status Summary section was difficult to view in Summary Reports.

Keywords: Summary, device status

Discovered in Release: v1.8.1

4952013

 

 

Description: Fixed an issue where an incorrect default agent interface name could cause the bring-up process to fail.

Keywords: Bringup

Discovered in Release: v1.8.1

4958379

 

 

Description: Fixed an issue where XDR pre-staging validation generated false reports in CVT.

Keywords: BER Pre-staging

Discovered in Release: v1.8.1

4680323

 

 

Description: Fixed an issue where topology files could not be downloaded from non-default topology directories.

Keywords: Download Topology

Discovered in Release: v1.8.1

4962749

 

 

Description: Fixed an issue where ping test parameters, including count and timeout values, were hardcoded and could not be modified by users.

Keywords: Ping Test

Discovered in Release: v1.8.1

4957106

 

 

DescriptionFixed an issue where tooltips displayed Rx/Tx power values in mW instead of dBm.

Keywords: Rx/Tx power, tooltip

Discovered in Release: v1.8.1

4959266

 

 

Description: Fixed an issue where unmanaged switches were hidden from rack view and node lists instead of being displayed as unavailable.

Keywords: Rack View, Unmanaged Device

Discovered in Release: v1.8.1

4974678

 

 

Description: Fixed an issue where some agents remained in a validation state and repeatedly restarted after pulling a new agent container image.

Keywords: Unresponsive Agent

Discovered in Release: v1.8.1

4973848

 

 

Description: Fixed an issue where administrator user accounts could be unintentionally removed from the database.

Keywords: Admin Iser

Discovered in Release: v1.8.1

4986197

 

 

Description: Fixed an issue where STARTUP_TOPOLOGY=last did not reload a topology previously loaded through the UI.

Keywords: STARTUP_TOPOLOGY

Discovered in Release: v1.8.1


Last updated: