Networking ConnectX 6 Family Firmware Release Notes

Bug Fixes in this Firmware Version

Internal Ref.

Issue

4575696

Description: Fixed an issue where multiple long-running process registers could cause aborted access and timeouts, the internal state is now properly handled.

Keywords: ibdiagnet2

Detected in version:

22.46.1006

Fixed in Release:

22.47.1026

4501554

Description: Fixed an assertion failure that could occur with the E-Switch uplink in specific configurations where the e-switch was disabled and Path Migration was active or GVMIs were using SRQ loopback in SQs. The issue occurred because the firmware attempted to perform cleanup operations when the uplink configuration lacked sufficient capacity.
Now, when the E-Switch is disabled and no actions are available in the uplink STE, the firmware connects to the uplink STE instead of copying it.

Keywords: Path migration, steering

Detected in version:

22.46.1006

Fixed in Release: 

22.47.1026

4531675

Description: Fixed an incorrect GPIO indication in the INI file that caused a false signal, preventing module initialization.

Keywords: GPIO indication

Detected in version:

22.45.1020

Fixed in Release:

22.47.1026

4529293

Description: Fixed an issue where, during failover or restart, the SM sending a PortInfo MAD to the HCA firmware triggered reinitialization of port buffers, momentarily halting ingress traffic and causing packet drops.
The firmware now avoids reconfiguring port buffers when the new configuration matches the current one.

Keywords: OpenSM

Detected in version:

22.45.1020

Fixed in Release:

22.47.1026

For a list of old Bug Fixes, please see Bug Fixes History.

Last updated: