Networking ConnectX 6 Family Firmware Release Notes

Bug Fixes in this Firmware Version

For a list of old Bug Fixes, please see Bug Fixes History.

Internal Ref.

Issue

3317361



Description: Added a safety mechanism to prevent the link from to getting stuck when receiving bad tuning results. In this case, the linkup flow is restarted and the mechanism retries to raise the link.

Keywords: Tuning

Discovered in Version: 

22.36.1010

Fixed in Release: 

22.37.1014

3337386



Description: Improved rate limit token re-distribution algorithm.

Keywords: Rate limit

Discovered in Version: 

22.36.1010

Fixed in Release: 

22.37.1014

3337386



Description: Improved non-consumed bandwidth re-distribution.

Keywords: Bandwidth

Discovered in Version: 

22.36.1010

Fixed in Release: 

22.37.1014

3395878



Description: Fixed an issue that resulted in no ping in NODNIC VF when VLAN stripping was enabled.

Keywords: NODNIC VF, VLAN

Discovered in Version: 

22.36.1010

Fixed in Release: 

22.37.1014

3352423



Description: Fixed an issue that caused vDPA application initialization to fail due to virtual queue creation failure.

The failure comes with the "0x8f7a: ring address translate failed" assert which indicates incorrect permission supplied by QEMU for virtual ring memory.

Keywords: virtio memory region

Discovered in Version: 

22.36.1010

Fixed in Release: 

22.37.1014

3327847



Description: CNP received, handled, and ignored counters in the hardware counters cannot work after moving to Programmable Congestion Control mode.

Keywords: CNP, Programmable Congestion Control

Discovered in Version: 

22.36.1010

Fixed in Release: 

22.37.1014