For a list of old Bug Fixes, please see Bug Fixes History.
|
Internal Ref. |
Issue |
|---|---|
|
3317361
|
Description: Added a safety mechanism to prevent the link from to getting stuck when receiving bad tuning results. In this case, the linkup flow is restarted and the mechanism retries to raise the link. |
|
Keywords: Tuning |
|
|
Discovered in Version: 22.36.1010 |
|
|
Fixed in Release: 22.37.1014 |
|
|
3337386
|
Description: Improved rate limit token re-distribution algorithm. |
|
Keywords: Rate limit |
|
|
Discovered in Version: 22.36.1010 |
|
|
Fixed in Release: 22.37.1014 |
|
|
3337386
|
Description: Improved non-consumed bandwidth re-distribution. |
|
Keywords: Bandwidth |
|
|
Discovered in Version: 22.36.1010 |
|
|
Fixed in Release: 22.37.1014 |
|
|
3395878
|
Description: Fixed an issue that resulted in no ping in NODNIC VF when VLAN stripping was enabled. |
|
Keywords: NODNIC VF, VLAN |
|
|
Discovered in Version: 22.36.1010 |
|
|
Fixed in Release: 22.37.1014 |
|
|
3352423
|
Description: Fixed an issue that caused vDPA application initialization to fail due to virtual queue creation failure. The failure comes with the |
|
Keywords: virtio memory region |
|
|
Discovered in Version: 22.36.1010 |
|
|
Fixed in Release: 22.37.1014 |
|
|
3327847
|
Description: CNP received, handled, and ignored counters in the hardware counters cannot work after moving to Programmable Congestion Control mode. |
|
Keywords: CNP, Programmable Congestion Control |
|
|
Discovered in Version: 22.36.1010 |
|
|
Fixed in Release: 22.37.1014 |
Last updated: