Internal Ref. |
Issue |
|---|---|
|
4575696 |
Description: Fixed an issue where multiple long-running process registers could cause aborted access and timeouts, the internal state is now properly handled. |
|
Keywords: ibdiagnet2 |
|
|
Detected in version: 22.46.1006 |
|
|
Fixed in Release: 22.47.1026 |
|
|
4501554 |
Description: Fixed an assertion failure that could occur with the E-Switch uplink in specific configurations where the e-switch was disabled and Path Migration was active or GVMIs were using SRQ loopback in SQs. The issue occurred because the firmware attempted to perform cleanup operations when the uplink configuration lacked sufficient capacity.
|
|
Keywords: Path migration, steering |
|
|
Detected in version: 22.46.1006 |
|
|
Fixed in Release: 22.47.1026 |
|
|
4531675 |
Description: Fixed an incorrect GPIO indication in the INI file that caused a false signal, preventing module initialization. |
|
Keywords: GPIO indication |
|
|
Detected in version: 22.45.1020 |
|
|
Fixed in Release: 22.47.1026 |
|
|
4529293 |
Description: Fixed an issue where, during failover or restart, the SM sending a PortInfo MAD to the HCA firmware triggered reinitialization of port buffers, momentarily halting ingress traffic and causing packet drops.
|
|
Keywords: OpenSM |
|
|
Detected in version: 22.45.1020 |
|
|
Fixed in Release: 22.47.1026 |
For a list of old Bug Fixes, please see Bug Fixes History.