Install the ConnectX-6 Dx OCP 3.0 card in a PCIe slot that is capable of supplying the power levels mentioned below for the appropriate use case.
-
ConnectX-6 Dx adapters supplement the auto-negotiation specification to get better bit error rates and longer cable reaches. This supplemental feature only initiates when connected to another NVIDIA Ethernet product.
-
In Standby mode only port0 is available.
Power numbers are provided for passive cables only. For board power numbers while using active cables, please add the outcome of the following formula to the passive cables' power numbers stated below.
Power while using Active Cables = Card Power with Passive Cable + Active Module Power x Number_of_Modules / 0.9 (efficiency factor).
MCX623432AE-ADAB / MCX623432AN-ADAB / MCX623432AC-ADAB / MCX623432AS-ADAB Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
|||||
|---|---|---|---|---|---|---|
|
Connector: Dual SFP28 Ethernet (copper and optical) |
||||||
|
Retention Mechanism: Thumbscrew (Pull Tab) Bracket |
||||||
|
Protocol Support |
Ethernet: 25GBASE-R, 20GBASE-KR2, 10GBASE-LR, 10GBASE-ER, 10GBASE-CX4, 10GBASE-KX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
|||||
|
Data Rate: |
Ethernet |
1/10/25 Gb/s |
||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
||||||
|
Capabilities |
MCX623432AE-ADAB: Crypto Enabled, No Secure Boot
|
|||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
|||||
|
|
Cable Type |
Active Mode |
Standby Mode |
|||
|
Typical Power(a) |
Passive Cables |
15.7W |
3.8W |
|||
|
Maximum Power |
Passive Cables |
19.74W |
7.95W |
|||
|
Maximum power available through SFP28 port: 1.5W |
||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
|||
|
Passive Cable |
Active Mode @55C |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
||
|
400LFM |
100LFM |
TBD |
TBD |
|||
|
Active 0.8W NVIDIA Cable |
400LFM |
100LFM |
TBD |
TBD |
||
|
Active 1.5W Cable |
500LFM |
150LFM |
TBD |
TBD |
||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
|||
|
Non-operational |
-40°C to 70°C |
|||||
|
Humidity |
Operational |
10% to 85% relative humidity |
||||
|
Non-operational |
10% to 90% relative humidity(b) |
|||||
|
Altitude (Operational) |
3050m |
|||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
|||||
|
RoHS |
RoHS compliant |
|||||
|
a. Typical power for ATIS traffic load.
|
||||||
MCX623432AC-GDAB / MCX623432AN-GDAB / MCX623432AS-GDAI Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
|||||
|---|---|---|---|---|---|---|
|
Connector: Dual SFP56 Ethernet (copper and optical) |
||||||
|
Retention Mechanism: |
MCX623432A[N/C]-GDAB: Thumbscrew (Pull Tab) Bracket |
|||||
|
MCX623432AS-GDAI: Internal Lock |
||||||
|
Protocol Support |
Ethernet: 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
|||||
|
Data Rate |
Ethernet |
1/10/25/40/50 Gb/s |
||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
||||||
|
Capabilities |
MCX623432AC-GDAB: Crypto Enabled, Secure Boot
|
|||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
|||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
|||
|
Typical Power(a) |
Passive Cables |
16.9W |
4.54W |
|||
|
Maximum Power |
Passive Cables |
21.4W |
8.75W |
|||
|
Maximum power available through SFP56 port: 2W |
||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
|||
|
Active Mode @55C |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
|||
|
Passive Cable |
400LFM |
100LFM |
TBD |
TBD |
||
|
Active 2W Cable |
800LFM |
200LFM |
TBD |
TBD |
||
|
Environmental
|
Temperature |
Operational |
0°C to 55°C |
|||
|
Non-operational |
-40°C to 70°C |
|||||
|
Humidity |
Operational |
10% to 85% relative humidity |
||||
|
Non-operational |
10% to 90% relative humidity(b) |
|||||
|
Altitude (Operational) |
3050m |
|||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
|||||
|
RoHS |
RoHS compliant |
|||||
|
a. Typical power for ATIS traffic load.
|
||||||
MCX623435MN-CDAB Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
|||||
|---|---|---|---|---|---|---|
|
Connector: Single QSFP56 Ethernet (copper and optical) |
||||||
|
Retention Mechanism: Thumbscrew (Pull Tab) Bracket |
||||||
|
Capabilities |
Multi-Host or Socket Direct, Crypto Disabled, No Secure Boot |
|||||
|
Protocol Support |
Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 100GBASE-CR2, 100GBASE-KR2, 100GBASE-SR2, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
|||||
|
Data Rate: |
Ethernet |
1/10/25/40/50/100 Gb/s |
||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
||||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
|||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
|||
|
Typical Power(a) |
Passive Cables |
18W |
5.7W |
|||
|
Maximum Power |
Passive Cables |
23.4W |
10W |
|||
|
Maximum power available through QSFP56 port: 5W |
||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
|||
|
Active Mode |
Standby Mode @45°C |
Active Mode @35C |
Standby Mode @35C |
|||
|
Passive Cable |
500LFM @55°C |
100LFM |
300LFM |
100LFM |
||
|
Active 2.2W NVIDIA Cable |
700LFM @55°C |
200LFM |
300LFM |
100LFM |
||
|
Active 3.5W Cable |
700LFM @50°C |
300LFM |
300LFM |
100LFM |
||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
|||
|
Non-operational |
-40°C to 70°C |
|||||
|
Humidity |
Operational |
10% to 85% relative humidity |
||||
|
Non-operational |
10% to 90% relative humidity(b) |
|||||
|
Altitude (Operational) |
3050m |
|||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
|||||
|
RoHS |
RoHS compliant |
|||||
|
a. Typical power for ATIS traffic load.
|
||||||
MCX623439MC-CDAB / MCX623439MN-CDAB Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
|||||
|---|---|---|---|---|---|---|
|
Connector: Single-port QSFP56 |
||||||
|
Retention Mechanism: |
Thumbscrew (Pull Tab) Bracket |
|||||
|
Capabilities |
MCX623439MC-CDAB: Multi Host or Socket Direct, Crypto Enabled, Secure Boot
|
|||||
|
Protocol Support |
Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 100GBASE-CR2, 100GBASE-KR2, 100GBASE-SR2, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
|||||
|
Data Rate: |
Ethernet |
1/10/25/40/50/100 Gb/s |
||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
||||||
|
Power and Environmental
|
Voltage: 3.3VAUX, 12V |
|||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
|||
|
Typical Power(a) |
Passive Cables |
17.22W |
4.3W |
|||
|
Maximum Power |
Passive Cables |
22.77W |
8.1W |
|||
|
Maximum power available through QSFP56 port: 5W |
||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
|||
|
Active Mode @55C |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
|||
|
Passive Cable |
600LFM |
100LFM |
Not Supported |
Not Supported |
||
|
Active Cables |
TBD |
TBD |
TBD |
TBD |
||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
|||
|
Non-operational |
-40°C to 70°C |
|||||
|
Humidity |
Operational |
10% to 85% relative humidity |
||||
|
Non-operational |
10% to 90% relative humidity(b) |
|||||
|
Altitude (Operational) |
3050m |
|||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
|||||
|
RoHS |
RoHS compliant |
|||||
|
a. Typical power for ATIS traffic load.
|
||||||
MCX623436AC-CDAB / MCX623436AN-CDAB / MCX623436AS-CDAI Specifications
|
Physical
|
Form Factor: Small Form Factor (SFF) OCP 3.0
|
||||||
|---|---|---|---|---|---|---|---|
|
Connector: Dual QSFP56 Ethernet (copper and optical) |
|||||||
|
Retention Mechanism
|
MCX623436A[N/C]-CDAB: Thumbscrew (Pull Tab) Bracket |
||||||
|
MCX623436AS-CDAI: Internal Lock Bracket |
|||||||
|
Capabilities |
MCX623436AC-CDAB(a): Crypto Enabled, Secure Boot, with Host Management
|
||||||
|
Protocol Support |
Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 100GBASE-CR2, 100GBASE-KR2, 100GBASE-SR2, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
||||||
|
Data Rate: |
Ethernet |
1/10/25/40/50/100 Gb/s |
|||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
|||||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
||||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
||||
|
Typical Power(b) |
Passive Cables |
19W |
5.7W |
||||
|
Maximum Power |
Passive Cables |
26.6W |
10W |
||||
|
Maximum power available through QSFP56 port: 5W |
|||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle @35C
|
||||
|
Active Mode |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
||||
|
Passive Cable |
600LFM @55C |
100LFM |
Not Supported |
Not Supported |
|||
|
Active 2.2W NVIDIA Cables |
1000LFM @55C |
300LFM |
Not Supported |
Not Supported |
|||
|
Active 3.5W |
800LFM @50C |
500LFM |
Not Supported |
Not Supported |
|||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
||||
|
Non-operational |
-40°C to 70°C(b) |
||||||
|
Humidity |
Operational |
10% to 85% relative humidity |
|||||
|
Non-operational |
10% to 90% relative humidity |
||||||
|
Altitude (Operational) |
3050m |
||||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
|||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
||||||
|
RoHS |
RoHS compliant |
||||||
|
(a) If your target application for this crypto-enabled card will utilize 100Gb/s or higher bandwidth, where a substantial part of the bandwidth will be allocated for IPsec traffic, please refer to the NVIDIA BlueField-2 DPUs Release Notes document to learn about a potential bandwidth limitation. See Related Documents section for details on accessing the document. Typical power for ATIS traffic load.
|
|||||||
MCX623436MN-CDAB / MCX623436MS-CDAB Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
|||||
|---|---|---|---|---|---|---|
|
Connector: Dual QSFP56 Ethernet (copper and optical) |
||||||
|
Retention Mechanism |
Thumbscrew (Pull Tab) Bracket |
|||||
|
Capabilities |
|
|||||
|
Protocol Support |
Ethernet: 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 100GBASE-CR2, 100GBASE-KR2, 100GBASE-SR2, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
|||||
|
Data Rate: |
Ethernet |
1/10/25/40/50/100 Gb/s |
||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
||||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
|||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
|||
|
Typical Power(a) |
Passive Cables |
19W |
5.7W |
|||
|
Maximum Power |
Passive Cables |
26.6W |
10W |
|||
|
Maximum power available through QSFP56 port: 5W |
||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
|||
|
Active Mode |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
|||
|
Passive Cable |
900LFM @55C |
100LFM |
Not Supported |
Not Supported |
||
|
Active 2.2W NVIDIA Cables |
700LFM @50C |
300LFM |
Not Supported |
Not Supported |
||
|
Active 3.5W |
800LFM @45C |
500LFM |
Not Supported |
Not Supported |
||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
|||
|
Non-operational |
-40°C to 70°C |
|||||
|
Humidity |
Operational |
10% to 85% relative humidity |
||||
|
Non-operational |
10% to 90% relative humidity(b) |
|||||
|
Altitude (Operational) |
3050m |
|||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
|||||
|
RoHS |
RoHS compliant |
|||||
|
a. Typical power for ATIS traffic load.
|
||||||
MCX623430MS-CDAB Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
||||||
|---|---|---|---|---|---|---|---|
|
Connector: Dual DSFP Ethernet (copper and optical) |
|||||||
|
Retention Mechanism: |
Thumbscrew (Pull Tab) Bracket |
||||||
|
Capabilities |
MCX623430MS-CDAB: Crypto disabled, Secure Boot enabled, with Multi-Host or Socket Direct |
||||||
|
Protocol Support |
Ethernet: 100GBASE-CR2, 100GBASE-KR2, 100GBASE-SR2, 50GBASE-R2, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
||||||
|
Data Rate: |
Ethernet |
1/10/25/40/50/100 Gb/s |
|||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
|||||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
||||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
||||
|
Typical Power(a) |
Passive Cables |
19W |
5.7W |
||||
|
Maximum Power |
Passive Cables |
26.6W |
10W |
||||
|
Maximum power available through DSFP port: 5W |
|||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
||||
|
Active Mode |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
||||
|
Passive Cable |
350LFM @55C |
100LFM |
150LFM |
100LFM |
|||
|
Active 2.5W Cables |
400LFM @45C |
200LFM |
200LFM |
100LFM |
|||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
||||
|
Non-operational |
-40°C to 70°C |
||||||
|
Humidity |
Operational |
10% to 85% relative humidity |
|||||
|
Non-operational |
10% to 90% relative humidity(b) |
||||||
|
Altitude (Operational) |
3050m |
||||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
|||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
||||||
|
RoHS |
RoHS compliant |
||||||
|
a. Typical power for ATIS traffic load.
|
|||||||
MCX623435AC-CDAB / MCX623435AE-CDAB / MCX623435AN-CDAB Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
|||||
|---|---|---|---|---|---|---|
|
Connector: Single QSFP56 Ethernet (copper and optical) |
||||||
|
Retention Mechanism |
Thumbscrew (Pull Tab) Bracket |
|||||
|
Capabilities |
|
|||||
|
Protocol Support |
Ethernet: 200GBASE-CR4, 200GBASE-KR4, 200GBASE-SR4, 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 100GBASE-CR2, 100GBASE-KR2, 100GBASE-SR2, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
|||||
|
Data Rate: |
Ethernet |
1/10/25/40/50/100/200 Gb/s |
||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
||||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
|||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
|||
|
Typical Power(a) |
Passive Cables |
16.9W |
5.6W |
|||
|
Maximum Power |
Passive Cables |
24W |
11.4W |
|||
|
Maximum power available through QSFP56 port: 5W |
||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
|||
|
Active Mode @55C |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
|||
|
Passive Cable |
400LFM |
100LFM |
250LFM |
100LFM |
||
|
Active 2.2W NVIDIA Cable |
700LFM |
200LFM |
250LFM |
100LFM |
||
|
Active 3.5W Cable |
700LFM(b) |
300LFM |
250LFM |
100LFM |
||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
|||
|
Non-operational |
-40°C to 70°C |
|||||
|
Humidity |
Operational |
10% to 85% relative humidity |
||||
|
Non-operational |
10% to 90% relative humidity(c) |
|||||
|
Altitude (Operational) |
3050m |
|||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
|||||
|
RoHS |
RoHS compliant |
|||||
|
(a) If your target application for this crypto-enabled card will utilize 100Gb/s or higher bandwidth, where a substantial part of the bandwidth will be allocated for IPsec traffic, please refer to the NVIDIA BlueField-2 DPUs Release Notes document to learn about a potential bandwidth limitation. See Related Documents section for details on accessing the document. Typical power for ATIS traffic load.
|
||||||
MCX623435AC-VDAB / MCX623435AN-VDAB / MCX623435AS-VDAI Specifications
|
Physical |
Form Factor: Small Form Factor (SFF) OCP 3.0
|
|||||
|---|---|---|---|---|---|---|
|
Connector: Single QSFP56 Ethernet (copper and optical) |
||||||
|
Retention Mechanism |
MCX623435A[N/C]-VDAB: Thumbscrew (Pull Tab) Bracket |
|||||
|
MCX623435AS-VDAI: Internal Lock |
||||||
|
Capabilities |
|
|||||
|
Protocol Support |
Ethernet: 200GBASE-CR4, 200GBASE-KR4, 200GBASE-SR4, 100GBASE-CR4, 100GBASE-KR4, 100GBASE-SR4, 100GBASE-CR2, 100GBASE-KR2, 100GBASE-SR2, 50GBASE-R2, 50GBASE-R4, 40GBASE-CR4, 40GBASE-KR4, 40GBASE-SR4, 40GBASE-LR4, 40GBASE-ER4, 40GBASE-R2, 25GBASE-R, 20GBASE-KR2, 10GBASE-LR,10GBASE-ER, 10GBASE-CX4, 10GBASE-CR, 10GBASE-KR, SGMII, 1000BASE-CX, 1000BASE-KX, 10GBASE-SR |
|||||
|
Data Rate |
Ethernet |
1/10/25/40/50/100/200 Gb/s |
||||
|
PCI Express Gen 4.0: SERDES @ 16.0GT/s, 16 lanes (2.0 and 1.1 compatible) |
||||||
|
Power and Airflow
|
Voltage: 3.3VAUX, 12V |
|||||
|
Power |
Cable Type |
Active Mode |
Standby Mode |
|||
|
Typical Power(a) |
Passive Cables |
16.9W |
5.6W |
|||
|
Maximum Power |
Passive Cables |
24W |
11.4W |
|||
|
Maximum power available through QSFP56 port: 5W |
||||||
|
Airflow |
Cable Type |
Hot Aisle
|
Cold Aisle
|
|||
|
Active Mode @55C |
Standby Mode @45C |
Active Mode @35C |
Standby Mode @35C |
|||
|
Passive Cable |
500LFM |
100LFM |
300LFM |
100LFM |
||
|
Active 4.55W Cables |
750LFM(b) |
600LFM |
300LFM |
100LFM |
||
|
Environmental |
Temperature |
Operational |
0°C to 55°C |
|||
|
Non-operational |
-40°C to 70°C |
|||||
|
Humidity |
Operational |
10% to 85% relative humidity |
||||
|
Non-operational |
10% to 90% relative humidity(c) |
|||||
|
Altitude (Operational) |
3050m |
|||||
|
Regulatory |
Safety |
CB / cTUVus / CE |
||||
|
EMC |
CE / FCC / VCCI / ICES / RCM |
|||||
|
RoHS |
RoHS compliant |
|||||
|
a. Typical power for ATIS traffic load.
|
||||||
Board Mechanical Drawing and Dimensions
All dimensions are in millimeters. The PCB mechanical tolerance is +/- 0.13mm.
|
ConnectX-6 Dx SFP28/SFP56 OCP 3.0 |
ConnectX-6 Dx Dual-Port QSFP56 OCP 3.0 |
ConnectX-6 Dx Single-Port QSFP56 OCP 3.0 |
|---|---|---|
|
|
|
|
Bracket Mechanical Drawings and Dimensions
All dimensions are in millimeters. The bracket's mechanical tolerance is +/- 0.25mm.
|
Dual-port SFP28/SFP56 Thumbscrew Bracket |
Dual-port QSFP56 Thumbscrew Bracket |
Single-port QSFP56 Thumbscrew Bracket |
|---|---|---|
|
|
|
|
Last updated: