ConnectX 6 Family Firmware Release Notes

Bug Fixes History


This section includes history of bug fixes of 3 major releases back. For older releases history, please refer to the relevant firmware versions Release Notes.



Internal Ref.

Issue

3985535

Description: Fixed an issue that caused RDE PortMetrics property Transceivers.SupplyVoltage to be reflected in incorrect units of 100uV instead of V.

Keywords: RDE

Discovered in Version:

20.41.1000

Fixed in Release:

20.42.1000

3938744

Description: Prevented HCA_CAP from allowing rogue drivers to create more EQs than the number allowed in the HCA_CAP.max_num_eqs. 

Keywords: HCA_CAP

Discovered in Version:

20.41.1000

Fixed in Release:

20.42.1000

3830017

Description: Fixed the MPLS packets discards flow when the GLOBAL pause capability is disabled.

Keywords: Global Pause

Discovered in Version:

20.41.1000

Fixed in Release:

20.42.1000



This version does not include bug fixes.



Internal Ref.

Issue

3641634

Description: Fixed an issue that occasionally caused RDE LLDPTransmit ChassisID to not be represented correctly.

Keywords: RDE LLDPTransmit ChassisID

Discovered in Version:

20.39.1002

Fixed in Release:

20.40.1000






Last updated: