VF Network Function Limitations in SR-IOV Legacy Mode
|
Dual Port Device |
Single Port Device |
|---|---|
|
127 VF per PF (254 functions) |
127 |
VF Network Function Limitations in Switchdev Mode
|
Dual Port Device |
Single Port Device |
|---|---|
|
127 VF per PF (254 functions) |
127 |
VF+SF Network Function Limitations in Switchdev Mode
|
Dual Port Device |
Single Port Device |
|---|---|
|
|
|
Internal Ref. |
Issue |
|---|---|
|
4893639 |
Description: Direct Memory Access (DMA) protection is not supported in the ipxe.efi driver. |
|
Workaround: N/A |
|
|
Keywords: DMA |
|
|
Detected in version: 28.47.1088 |
|
|
4635705 |
Description: The power-up time of a server with multiple ConnectX NICs may be significantly longer when DMA protection is enabled in the server BIOS and the server has five or more NICs configured for InfiniBand. |
|
Workaround: N/A |
|
|
Keywords: Power-up time, DMA protection BIOS |
|
|
Detected in version: 28.49.1014 |
|
|
4285063 |
Description: mlxconfig may report incorrect default INI parameter values when queried, even though the Current and Next boot values are reported correctly. |
|
Workaround: N/A |
|
|
Keywords: mlxconfig
|
|
|
Detected in version: 28.48.1000 |
|
|
4604969 |
Description: Probe packets might be dropped at the transmission stage when multiple congestion control flows are active. |
|
Workaround: N/A |
|
|
Keywords: PCC, RTT, probe
|
|
|
Detected in version: 28.47.1026 |
|
|
4436870 |
Description: PCIe link speed may degrade after a disable/enable operation. |
|
Workaround: A manual retrain command is required to restore full speed. |
|
|
Keywords: PCIe
|
|
|
Detected in version: 40.47.1026 |
|
|
4496642 |
Description: The timestamps (t2, t4) of the received RTT probes are taken from the free-running clock, even when ROCE_CC_RTT_TIMESTAMP_FORMAT is set to 0x02.
|
|
Workaround: N/A |
|
|
Keywords: RTT RTC timestamp
|
|
|
Detected in version: 28.47.1026 |
|
|
4705241 |
Description: When Quantum-2 is part of an XDR topology, serving as a leaf switch connected to NDR-based hosts, a bandwidth degradation of approximately 3–7 Gb/s is expected. |
|
Workaround: N/A |
|
|
Keywords: XDR, NDR, Quantum-2
|
|
|
Detected in version: 28.47.1026 |
|
|
4705948 |
Description: When using DC as the InfiniBand transport type to perform an ib_read RDMA operation between ConnectX-7 (NDR) and ConnectX-8, a bandwidth degradation of approximately 25% may be observed when using a low number of QPs (1–16). The performance degradation diminishes as the number of QPs increases. |
|
Workaround: N/A |
|
|
Keywords: DC, ib_read RDMA, NDR, performance
|
|
|
Detected in version: 28.47.1026 |
|
|
4685736 |
Description: Creating a DPA process that allocates a 128 MB data segment and loads a dynamic library may fail with syndrome 0xdc30ac. |
|
Workaround: Limit the DPA application’s data segment size to 64 MB. |
|
|
Keywords: DPA
|
|
|
Detected in version: 28.47.1026 |
|
|
4628696 |
Description: When HASH LAG single QP is enabled, ib_read_bw for a single QP over hash LAG can reach up to 337 Gbps, while ib_write_bw for a single QP can achieve up to 390 Gbps. |
|
Workaround: N/A |
|
|
Keywords: HASH LAG single QP
|
|
|
Detected in version: 28.47.1026 |
|
|
4657082 |
Description: PTP holdover is not supported on FireFly without SyncE; it is available only when using Servo. |
|
Workaround: N/A |
|
|
Keywords: PTP Holdover
|
|
|
Detected in version: 28.47.1026 |
|
|
4394475 |
Description: The existing congestion control configuration applies globally, rather than on a per-priority basis. |
|
Workaround: Ensure that the configuration values for all priorities are aligned in either |
|
|
Keywords: Congestion control, ROCE_CC_PRIO
|
|
|
Detected in version: 28.45.1020 |
|
|
4063662 |
Description: The 1pps Timing Error (TE) in Noise Generation (Class B) shows a constant offset when RS-FEC is disabled in the mlxlink option. |
|
Workaround: N/A |
|
|
Keywords: PTP, 1PPS
|
|
|
Detected in version: 28.45.1020 |
|
|
4303583 |
Description: The query_header_modify_pattern command may produce inaccurate results when specific fields are used. |
|
Workaround: N/A |
|
|
Keywords: query_header_modify_pattern command
|
|
|
Detected in version: 28.45.1020 |
|
|
3875417 |
Description: For systems that support a large number of VFs (200 or more) and can open over a million QPs, the FLR may take about 1 second per function resulting in a driver timeout. |
|
Workaround: N/A |
|
|
Keywords: VFs, QPs, FLR
|
|
|
Detected in version: 28.44.1204 |
|
|
4193036 |
Description: The initial allocation of DPA_THREAD on group affinity allocates memory for all EUs, including stack, core dump, and other resources. |
|
Workaround: N/A |
|
|
Keywords: DPA
|
|
|
Detected in version: 28.44.1204 |
|
|
4030457 |
Description: This release does not support InfiniBand (IB) over Windows OS when using ConnectX-7 MCX75310AAS-NEAT and MCX75310AAC-NEAT OPNs. |
|
Workaround: N/A |
|
|
Keywords: InfiniBand, Windows
|
|
|
Detected in version: 28.42.1000 |
|
|
- |
Description: Downgrading the following adapter cards (MCX713104AS-ADAT & MCX713104AC-ADAT) to a lower version than 20.39.2048 is not supported. |
|
Workaround: N/A |
|
|
Keywords: Downgrade |
|
|
Discovered in Version: 28.40.1000 |
|
|
3728450
|
Description: SW_RESET with a pending image is currently not supported. |
|
Workaround: N/A |
|
|
Keywords: SW_RESET |
|
|
Discovered in Version: 28.40.1000 |
|
|
3614362 |
Description: When connected to a Spectrum-1 switch system using NRZ 25G optic module supporting DME in NO FEC, an EFF BER of -13 may be seen once in 200 toggles. |
|
Workaround: To raise the link, re-toggle the port. |
|
|
Keywords: Spectrum-1, NRZ, BER, port toggling |
|
|
Discovered in Version: 28.39.1002 |
|
|
3629216
|
Description: mlxfwreset level 3 command is not supported for MCX750500B-0D00 / MCX750500B-0D0K / MCX755206AS-NEAT-N P/N. |
|
Workaround:
|
|
|
Keywords: mlxfwreset level 3 |
|
|
Discovered in Version: 28.39.1002 |
|
|
-
|
Description: The I2C clock fall time is lower than the 12ns minimum defined in the I2C-bus specification. For further information, refer to the I²C-bus Specification, Version 7.0, October 2021, https://www.i2c-bus.org/. |
|
Workaround: N/A |
|
|
Keywords: I2C clock |
|
|
Discovered in Version: 28.39.1002 |
|
|
3179534
|
Description: 25G/lane speeds are not supported on 200GbE optic cables. |
|
Workaround: N/A |
|
|
Keywords: Cables, 200GbE |
|
|
Discovered in Version: 28.39.1002 |
|
|
3435259
|
Description: The host enables the device to populate only 1 bus. When opening extra 2 Physical ports, moving from dual-port to quad-port, the user can open 2 less Virtual Functions. |
|
Workaround: N/A |
|
|
Keywords: VF, dual-port, quad-port |
|
|
Discovered in Version: 28.39.1002 |
|
|
3525865
|
Description: Unexpected system behavior might be observed if the driver is loaded while reset is in progress. |
|
Workaround: N/A |
|
|
Keywords: Sync 1 reset, firmware reset |
|
|
Discovered in Version: 28.39.1002 |
|
|
3363753
|
Description: The link is down when connected to the MMS1V00-WM (DR4) optical module. |
|
Workaround: N/A |
|
|
Keywords: 400G, link down |
|
|
Discovered in Version: 28.38.1002 |
|
|
3439438
|
Description: When connecting to a High Speed Traffic Generator in 400G speed, the linkup time may takes up to 3 minutes. |
|
Workaround: N/A |
|
|
Keywords: 400G, linkup time |
|
|
Discovered in Version: 28.38.1002 |
|
|
-
|
Description: When upgrading from firmware v28.35.2000 to a newer one, the default port speeds of adapter cards MCX755106AS-HEAT/ MCX755106AC-HEAT will change from InfiniBand to Ethernet. |
|
Workaround: To change it back to InfiniBand, please follow the instructions in the ConnectX-7 hardware User Manual. |
|
|
Keywords: Firmware upgrade, port type, MCX755106AS-HEAT/ MCX755106AC-HEAT |
|
|
Discovered in Version: 28.37.1014 |
|
|
3376224
|
Description: FEC override is not supported when working with NRZ speeds on PAM4 Optical modules. |
|
Workaround: N/A |
|
|
Keywords: FEC override, NRZ, PAM4 |
|
|
Discovered in Version: 28.37.1014 |
|
|
3262845 |
Description: In the ConnectX-7 adapter card with P/N MCX750500B-0D0K, the "Fatal Error Reporting Enable" bit controls both the fatal and the non-fatal ERR MSG forwarding. The "Non-Fatal Error Reporting Enable" bit does not affect the ERR MSG forwarding. |
|
Workaround: N/A |
|
|
Keywords: Fatal Error Reporting Enable" bit, PCIe, MCX750500B-0D0K |
|
|
Discovered in Version: 28.36.1010 |
|
|
3329109
|
Description: MFS1S50-H003E cable supports only HDR rate when used as a split cable. |
|
Workaround: N/A |
|
|
Keywords: HDR, split cable, MFS1S50-H003E |
|
|
Discovered in Version: 28.36.1010 |
|
|
2844036
|
Description: When using the "Dual Write" feature with QP buffer bigger than the maximum outstanding WQEs (128), the data being sent on the standby QP can be corrupted. |
|
Workaround: Limit the QP buffer size when using "Dual Write" up to 128 WQEs. |
|
|
Keywords: Dual-write, QP |
|
|
Discovered in Version: 28.36.1010 |
|
|
3178339
|
Description: PCIe PML1 is disabled. |
|
Workaround: N/A |
|
|
Keywords: PCIe PML1 |
|
|
Discovered in Version: 28.35.1012 |
|
|
3033910 |
Description: BAR misses caused by a memory write/read actions are not reported in the AER and the device status. |
|
Workaround: N/A |
|
|
Keywords: BAR miss, AER |
|
|
Discovered in Version: 28.34.4000 |
|
|
3140645
|
Description: 3rd party servers may hang after warm reboot due to the PCIe switch. |
|
Workaround: N/A |
|
|
Keywords: PCIe, 3rd party servers |
|
|
Discovered in Version: 28.34.4000 |
|
|
-
|
Description: Changing dynamic PCIe link width is not supported. |
|
Workaround: N/A |
|
|
Keywords: PCIe |
|
|
Discovered in Version: 28.34.1002 |
|
|
3141072
|
Description: The "max_shaper_rate" configuration query via QEEC mlxreg returns a value translated to hardware granularity. |
|
Workaround: N/A |
|
|
Keywords: RX Rate-Limiter, Multi-host |
|
|
Discovered in Version: 28.34.1002 |
|
|
2870970 |
Description: GTP encapsulation (flex parser profile 3) is limited to the NIC domain. Encapsulating in the FDB domain will render a 0-size length in GTP header. |
|
Workaround: N/A |
|
|
Keywords: GTP encapsulation |
|
|
Discovered in Version: 28.34.1002 |
|
|
3081264
|
Description: 10G/40G speeds are not supported on MFS1S00-XXXX modules (200G optics) in ConnectX-7 adapter cards. |
|
Workaround: N/A |
|
|
Keywords: Optical cables |
|
|
Discovered in Version: 28.33.4030 |
|
|
3070590
|
Description: PLL modules are not supported in ConnectX-7 ethernet adapter cards. |
|
Workaround: N/A |
|
|
Keywords: PLL |
|
|
Discovered in Version: 28.33.4030 |
|
|
3070409
|
Description: When connecting a ConnectX-7 adapter card to a ConnectX-6 Dx or an NVIDIA Spectrum-3 switch, NRZ speeds are not raised when using 200GbE optical cable. |
|
Workaround: Configure PHY_FEC_OVERRIDE on the ConnectX-7 side for the requested speed. |
|
|
Keywords: Optical cables, NRZ, ConnectX-6 Dx, NVIDIA Spectrum-3, 200GbE optical cable |
|
|
Discovered in Version: 28.33.4030 |
|
|
- |
Description: Upgrading to firmware 28.33.2028 from any previous Engineering Sample (earlier than version 28.98.2406) must be done before installing WinOF-2 v2.90 driver and requires going through the following steps:
|
|
Workaround: N/A |
|
|
Keywords: Firmware upgrade |
|
|
Discovered in Version: 28.33.2028 |
|
|
- |
Description: Downgrading from firmware 28.33.2028 to any previous Engineering Sample firmware is not supported. |
|
Workaround: N/A |
|
|
Keywords: Firmware downgrade |
|
|
Discovered in Version: 28.33.2028 |
Last updated: