ConnectX-7 has the same feature set and limitations as ConnectX-6 adapter card. For the list of ConnectX-6 Known Issues, please go to https://docs.nvidia.com/networking/category/connectx6fw.
The below are limitations related to ConnectX-7 only.
|
Internal Ref. |
Issue |
|---|---|
|
3036791
|
Description: Configuring 400G_8x in force mode is currently not supported. |
|
Workaround: N/A |
|
|
Keywords: 400G_8x in force mode |
|
|
Discovered in Version: 28.33.4030 |
|
|
3085879
|
Description: On rare occasions, when connecting a ConnectX-7 adapter card to an NVIDIA Spectrum-3 switch system using the optical cable OPN MFA1A00-C003, the link up time is ~7sec. |
|
Workaround: N/A |
|
|
Keywords: Optical cables, link up time |
|
|
Discovered in Version: 28.33.4030 |
|
|
3081264
|
Description: 10G/40G speeds are not supported on MFS1S00-XXXX modules (200G optics) in ConnectX-7 adapter cards. |
|
Workaround: N/A |
|
|
Keywords: Optical cables |
|
|
Discovered in Version: 28.33.4030 |
|
|
3070590
|
Description: PLL modules are not supported in ConnectX-7 ethernet adapter cards. |
|
Workaround: N/A |
|
|
Keywords: PLL |
|
|
Discovered in Version: 28.33.4030 |
|
|
3009525
|
Description: A Bit Error Rate (BER) of 1e-9 might occur when using optical cables. |
|
Workaround: N/A |
|
|
Keywords: BER |
|
|
Discovered in Version: 28.33.4030 |
|
|
3004352
|
Description: LRO is currently not supported. |
|
Workaround: N/A |
|
|
Keywords: LRO |
|
|
Discovered in Version: 28.33.4030 |
|
|
3073517
|
Description: When connecting a ConnectX-7 adapter card to a ConnectX-5 or an NVIDIA Spectrum switch and trying to raise 10G/40G over 100G optics cable is not supported. |
|
Workaround: N/A |
|
|
Keywords: Optical cables, ConnectX-5, NVIDIA Spectrum |
|
|
Discovered in Version: 28.33.4030 |
|
|
3073517
|
Description: When connecting a ConnectX-7 adapter card to a ConnectX-5 or an NVIDIA Spectrum switch, configuring first 10G/40G and then configuring back 100G we result in linkup failure. |
|
Workaround: Toggle both ConnectX-7 and ConnectX-5 or the NVIDIA Spectrum switch |
|
|
Keywords: ConnectX-5, NVIDIA Spectrum, linkup |
|
|
Discovered in Version: 28.33.4030 |
|
|
3070409
|
Description: When connecting a ConnectX-7 adapter card to a ConnectX-6 Dx or an NVIDIA Spectrum-3 switch, NRZ speeds are not raised when using 200GbE optical cable. |
|
Workaround: Configure PHY_FEC_OVERRIDE on the ConnectX-7 side for the requested speed. |
|
|
Keywords: Optical cables, NRZ, ConnectX-6 Dx, NVIDIA Spectrum-3, 200GbE optical cable |
|
|
Discovered in Version: 28.33.4030 |
|
|
2993531
|
Description: PML1 is disabled by default. Enabling it might result in server hanging. |
|
Workaround: N/A |
|
|
Keywords: PML1 |
|
|
Discovered in Version: 28.33.2028 |
|
|
2824427
|
Description: Running with a debug firmware reduces security as if token was applied. |
|
Workaround: N/A |
|
|
Keywords: Debug Firmware |
|
|
Discovered in Version: 28.33.2028 |
|
|
3046168
|
Description: Congestion Control is not enabled when one link type of different ports is different. |
|
Workaround: N/A |
|
|
Keywords: Congestion Control, Link Type, PCC |
|
|
Discovered in Version: 28.33.2028 |
|
|
3039348
|
Description: Host Chaining is currently not supported in ConnectX-7 adapter cards. |
|
Workaround: N/A |
|
|
Keywords: Host Chaining |
|
|
Discovered in Version: 28.33.2028 |
|
|
3023751
|
Description: Link flapping may occur when using ConnectX-7 adapter cards with HDR optic cables. |
|
Workaround: N/A |
|
|
Keywords: Link flapping, HDR optic cables |
|
|
Discovered in Version: 28.33.2028 |
|
|
2920813
|
Description: The
The flow is supported only when configuring FEC using the PPLM register. |
|
Workaround: N/A |
|
|
Keywords: AN, cables, 25GbE, FEC |
|
|
Discovered in Version: 28.33.2028 |
|
|
-
|
Description: Upgrading to firmware 28.33.2028 from any previous Engineering Sample (earlier than version 28.98.2406) must be done before installing WinOF-2 v2.90 driver and requires going through the following steps:
|
|
Workaround: N/A |
|
|
Keywords: Firmware upgrade |
|
|
Discovered in Version: 28.33.2028 |
|
|
-
|
Description: Downgrading from firmware 28.33.2028 to any previous Engineering Sample firmware is not supported. |
|
Workaround: N/A |
|
|
Keywords: Firmware downgrade |
|
|
Discovered in Version: 28.33.2028 |