Internal Ref. |
Issue |
|---|---|
|
2931516
|
Description: Added support for SPDM Get_measurements command. Note: Executing the command with a signature request without measurements, can cause an invalid L1 hash calculation. |
|
Keywords: SPDM |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3091233
|
Description: Added support for SPDM Challenge command. |
|
Keywords: SPDM |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
2907008
|
Description: Fixed PCIe link down failures during PCIe speed change tests. |
|
Keywords: PCIe, link down |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3134894
|
Description: Fixed an issue where |
|
Keywords: ASO Flow Meter, FW Steering |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3039007
|
Description: Enabled Multi-Host RX Rate-limiter configuration via the QEEC mlxreg and the max_shaper_rate field. |
|
Keywords: RX Rate-Limiter, Multi-host |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3059379
|
Description: Added "Command Unsupported" response code in cases when running the MCTP control command "Get Vendor Defined Messages Supported", and there were no supported VDMs. |
|
Keywords: MCTP control command |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3133476
|
Description: Added the following new checks to commands' interface:
|
|
Keywords: Command checks |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3047521
|
Description: Implemented a firmware flow to power up/down the PLL from downstream links upon PERST assertion/de-assertion. |
|
Keywords: PLL, PERST |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3132594
|
Description: MAC allocation in adapter cards that support Port-Per-Host feature ("host isolation") is reordered to fit the required range.
|
|
Keywords: MAC allocation, PortPerHost |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3085879 |
Description: On rare occasions, when connecting a ConnectX-7 adapter card to an NVIDIA Spectrum-3 switch system using the optical cable OPN MFA1A00-C003, the link up time is ~7sec. |
|
Keywords: Optical cables, link up time |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
2994292
|
Description: Fixed a race condition occured between the duplicate read and QP commands (2RST, 2ERR and Destroy) in the signature that caused the command to hang. |
|
Keywords: Race condition |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3023847
|
Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
|
Keywords: MetroX, LID based |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3023847
|
Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
|
Keywords: MetroX, LID based |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
2920813
|
Description: The
The flow is supported only when configuring FEC using the PPLM register. |
|
Keywords: AN, cables, 25GbE, FEC |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3039348
|
Description: Host Chaining is currently not supported in ConnectX-7 adapter cards. |
|
Keywords: Host Chaining |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3023751
|
Description: Link flapping may occur when using ConnectX-7 adapter cards with HDR optic cables. |
|
Keywords: Link flapping, HDR optic cables |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3046168
|
Description: Congestion Control is not enabled when one link type of different ports is different. |
|
Keywords: Congestion Control, Link Type, PCC |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3009525
|
Description: A Bit Error Rate (BER) of 1e-9 might occur when using optical cables. |
|
Keywords: BER |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3036791
|
Description: Configuring 400G_8x in force mode is currently not supported. |
|
Keywords: 400G_8x in force mode |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3004352
|
Description: LRO is currently not supported. |
|
Keywords: LRO |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
Last updated: