Internal Ref. |
Issue |
|---|---|
|
3110205
|
Description: Fixed inconsistent TCP performance when sending multiple streams. |
|
Keywords: Performance |
|
|
Discovered in Version: 28.34.1002 |
|
|
Fixed in Release: 28.34.4000 |
|
|
3138401
|
Description: Fixed an issue that caused host's PCI device to disappear after running 12V cycles in a loop while there was traffic between the hosts in a Multi-Host platform. |
|
Keywords: PCI device, Multi-Host platform, 12V cycles |
|
|
Discovered in Version: 28.34.1002 |
|
|
Fixed in Release: 28.34.4000 |
|
|
3148833
|
Description: Fixed an issue that resulted in lack of communication with the BMC from the host (IPv4/IPv6) when using BMC version v2022.22.1. |
|
Keywords: BMC |
|
|
Discovered in Version: 28.34.1002 |
|
|
Fixed in Release: 28.34.4000 |
|
|
3143956
|
Description: When connecting a ConnectX-7 adapter card to ConnectX-7 adapter card, once in few fwresets the link may raise in 1G speed instead of the highest speed enabled. |
|
Keywords: Speed rate |
|
|
Discovered in Version: 28.34.1002 |
|
|
Fixed in Release: 28.34.4000 |
|
Internal Ref. |
Issue |
|---|---|
|
2931516
|
Description: Added support for SPDM Get_measurements command. Note: Executing the command with a signature request without measurements, can cause an invalid L1 hash calculation. |
|
Keywords: SPDM |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3091233
|
Description: Added support for SPDM Challenge command. |
|
Keywords: SPDM |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
2907008
|
Description: Fixed PCIe link down failures during PCIe speed change tests. |
|
Keywords: PCIe, link down |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3134894
|
Description: Fixed an issue where |
|
Keywords: ASO Flow Meter, FW Steering |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3039007
|
Description: Enabled Multi-Host RX Rate-limiter configuration via the QEEC mlxreg and the max_shaper_rate field. |
|
Keywords: RX Rate-Limiter, Multi-host |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3059379
|
Description: Added "Command Unsupported" response code in cases when running the MCTP control command "Get Vendor Defined Messages Supported", and there were no supported VDMs. |
|
Keywords: MCTP control command |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3133476
|
Description: Added the following new checks to commands' interface:
|
|
Keywords: Command checks |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3047521
|
Description: Implemented a firmware flow to power up/down the PLL from downstream links upon PERST assertion/de-assertion. |
|
Keywords: PLL, PERST |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3132594
|
Description: MAC allocation in adapter cards that support Port-Per-Host feature ("host isolation") is reordered to fit the required range.
|
|
Keywords: MAC allocation, PortPerHost |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3085879 |
Description: On rare occasions, when connecting a ConnectX-7 adapter card to an NVIDIA Spectrum-3 switch system using the optical cable OPN MFA1A00-C003, the link up time is ~7sec. |
|
Keywords: Optical cables, link up time |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
2994292
|
Description: Fixed a race condition occured between the duplicate read and QP commands (2RST, 2ERR and Destroy) in the signature that caused the command to hang. |
|
Keywords: Race condition |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3023847
|
Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
|
Keywords: MetroX, LID based |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3023847
|
Description: Enabled sending and receiving traffic with a different LID than the host LID in MetroX applications. |
|
Keywords: MetroX, LID based |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
2920813
|
Description: The
The flow is supported only when configuring FEC using the PPLM register. |
|
Keywords: AN, cables, 25GbE, FEC |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3039348
|
Description: Host Chaining is currently not supported in ConnectX-7 adapter cards. |
|
Keywords: Host Chaining |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3023751
|
Description: Link flapping may occur when using ConnectX-7 adapter cards with HDR optic cables. |
|
Keywords: Link flapping, HDR optic cables |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3046168
|
Description: Congestion Control is not enabled when one link type of different ports is different. |
|
Keywords: Congestion Control, Link Type, PCC |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3009525
|
Description: A Bit Error Rate (BER) of 1e-9 might occur when using optical cables. |
|
Keywords: BER |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3036791
|
Description: Configuring 400G_8x in force mode is currently not supported. |
|
Keywords: 400G_8x in force mode |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
|
3004352
|
Description: LRO is currently not supported. |
|
Keywords: LRO |
|
|
Discovered in Version: 28.33.4030 |
|
|
Fixed in Release: 28.34.1002 |
|
Internal Ref. |
Issue |
|---|---|
|
2969829
|
Description: On rare occasions, the HDR speed link up time when using the optical module MFA7U10-H010 might take up to 70sec. |
|
Keywords: HDR, link up time, optical cable |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3024199
|
Description: When connecting a ConnectX-7 adapter card to an NVIDIA Quantum switch using the copper cable (MCP1600-E01AE30), the link is Down when in EDR speed. |
|
Keywords: EDR, copper cable, NVIDIA Quantum |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
2947588
|
Description: Trying to query/burn the firmware using the flint utility when the image is pending (after firmware burn and before firmware reset), results in the action's failure. |
|
Keywords: flint, query/burn firmware |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3047723
|
Description: When changing the protocols from ETH to IB on two ConnectX-7 adapter cards connected to each other, the ports on both sides must be toggled to get the link up. |
|
Keywords: Linkup, port toggling, protocol change |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
|
|
3033874 |
Description: Connecting a ConnectX-7 adapter card to either a ConnectX-5 adapter card or to an NVIDIA Spectrum switch system is supported only when using a 100GbE optic cables and when configuring ConnectX-5 or the NVIDIA Spectrum switch system to Force Mode. |
|
Keywords: Linkup connectivity |
|
|
Discovered in Version: 28.33.2028 |
|
|
Fixed in Release: 28.33.4030 |
Last updated: