ConnectX-9 has the same feature set and limitations as the ConnectX-8 SuperNIC. For the list of ConnectX-8 known issues, refer to: https://docs.nvidia.com/networking/software/adapter-firmware/index.html#connectx-8.
The limitations listed below apply to ConnectX-9 only.
|
Internal Ref. |
Issue |
|---|---|
|
4835832 |
Description: In rare cases, certain module types may experience link-up failures. |
|
Workaround: Configure the requested speed using the following commands:
|
|
|
Keywords: Cables
|
|
|
Detected in version: 82.48.1000 |
|
|
4809493 / 4804815 / 4884845 |
Description: Running lane margin tests may disrupt traffic, cause connection drops, or degrade performance. |
|
Workaround:
|
|
|
Keywords: Lane Margin |
|
|
Detected in version: 82.48.1000 |
|
|
4806964 / 48293338 / 4843305 / 4857738 |
Description: When bringing up 800G_8x on ConnectX-9 with Spectrum-4 switch systems, switch firmware version xx.201.3916-020 or later is required; earlier versions may fail to link up at 800G_8x. |
|
Workaround: N/A |
|
|
Keywords: Linkup, cables, Spectrum-4, 800G_8x |
|
|
Detected in version: 82.48.1000 |
|
|
|
Description: 200GbE per lane protocol is currently not supported. |
|
Workaround: N/A |
|
|
Keywords: 200GbE per lane
|
|
|
Detected in version: 82.48.1000 |
Last updated: