Use this section when a controlled endpoint-to-endpoint RDMA test passes, but an RDMA application, collective, or NVIDIA Collective Communications Library (NCCL) workload fails, hangs, times out, or performs poorly.
Quick Decision
|
What you see |
Do this next |
|---|---|
|
The adapter, PCIe, or physical link is unhealthy. |
Refer to Device Visibility and PCIe or Physical Link, Cable, Optic, FEC, and BER, depending on the symptom. |
|
A basic endpoint-to-endpoint RDMA test fails. |
Refer to InfiniBand Fabric Triage or RoCE Transport Triage. |
|
Basic RDMA works, but one workload fails. |
Refer to Capture the Workload Evidence, and isolate the affected process, rank, node, or rail. |
|
The failure follows a specific NIC or network path. |
Refer to the relevant section: Physical Link, Cable, Optic, FEC, and BER, InfiniBand Fabric Triage, or RoCE Transport Triage. Include the NIC, rail, or path mapping. |
|
The failure is a collective hang, imbalance, or low bandwidth. |
Capture the Workload Evidence
Before you change environment variables, network policy, or application settings, record the following:
-
Exact command, container or package version, and workload configuration
-
Start time, timeout, error text, and reproduction rate
-
Participating nodes, process or rank mapping, and affected interfaces or rails
-
Whether a smaller job, a single node, or a controlled endpoint-to-endpoint test succeeds
-
Good-state and bad-state host bundles, if the failure is intermittent
-
Transport and switch evidence for the same time window
Isolate the Failure Domain
-
Run a controlled endpoint-to-endpoint RDMA test on the affected path.
-
If the test fails, Refer to InfiniBand Fabric Triage or RoCE Transport Triage.
-
If the test passes, reduce the workload: use fewer nodes, fewer ranks, or one rail at a time.
-
Determine whether the failure follows a node, rank, NIC, rail, topology placement, or workload version.
-
Compare the failing case with a known-good workload run, changing one setting at a time.
Don't change several workload and network settings together. Treat a workaround as a lead until a controlled comparison confirms what changed.
NCCL First Checks
For an NCCL collective issue, collect the exact environment, the rank-to-node mapping, the incident time, and a separate NCCL log for each rank.
|
Purpose |
NCCL Setting |
|---|---|
|
Standard focused reproduction |
|
|
Focus on setup and network transport |
|
|
Deeper diagnosis of the smallest reproducer |
|
|
Preserve logs per rank |
|
-
Run the focused reproduction with
NCCL_DEBUG=INFOand preserve output from every participating rank. -
Add
NCCL_DEBUG_SUBSYS=INIT,NETwhen the investigation is about initialization or network transport. -
If INFO does not identify the failing stage, repeat the smallest reproducer with
NCCL_DEBUG=DEBUGorNCCL_DEBUG=TRACE. -
Pair the NCCL logs with endpoint snapshots and switch evidence from the same time window.
Use high verbosity only for a scoped reproduction. TRACE can generate a large volume of logs and should not be enabled broadly or indefinitely.
Interpret the Result
|
Finding |
Next step |
|---|---|
|
NCCL identifies a specific NIC, rail, or path. |
Refer to the matching transport or physical-link section. |
|
NCCL shows a setup, topology, or locality inconsistency. |
Compare node, rank, GPU, and NIC placement with a known-good run. |
|
A minimal NCCL test fails. |
Keep the test output, and continue with step 3 of Isolate the Failure Domain. |
|
A minimal NCCL test passes, but the application fails. |
Compare the application configuration and communication pattern with the working test. |
|
The failure appears only at scale. |
Reduce by nodes, ranks, or rails to find the first scale that fails. |
Escalation Criteria
Contact NVIDIA Enterprise Support or your OEM/reseller support provider, depending on your support agreement, if any of the following conditions applies:
-
Basic RDMA connectivity is healthy, but the workload failure still reproduces.
-
The failure follows a rank, process placement, workload version, or application configuration.
-
The collective fails only at scale or only with a specific topology.
Attachments
-
Exact workload command and configuration
-
NCCL log for each rank
-
Node, rank, GPU, NIC, interface, and rail mapping
-
Incident timing
-
Host bundles
-
Controlled RDMA test result
-
Minimal NCCL test result
-
Known-good comparison
-
Relevant transport or switch evidence
For the full escalation package, see Escalation Package and Handoff.