DOCA Framework Bug Fixes
|
Ref # |
Issue |
|---|---|
|
4564535 |
Description: Under high flow-insertion rates on BlueField-3, pipe resize operations may time out (exceeding 10 seconds). This can cause OVS threads ( |
|
Keyword: OVS; Pipe Resize; Timeout |
|
|
Detected in version: 3.1.0 |
|
|
4564538 |
Description: A pipe resize operation on BlueField-3, often triggered by dynamic flow limits, may fail. This can result in memory allocation errors and severe delays (10+ seconds), leading to a loss of network connectivity, such as BGP peering sessions dropping. |
|
Keyword: Pipe Resize; Flow Limit; Memory Allocation |
|
|
Detected in version: 3.1.0 |
|
|
4621473 |
Description: A race condition during flow deletion may cause application instability or incorrect counter values. |
|
Keyword: Flow; delete |
|
|
Detected in version: 3.1.0 |
|
|
4366800 |
Description: Creating a packet filtering rule with match criteria on certain unsupported fields (e.g., specific VXLAN-GPE flags) does not return an error as expected. |
|
Keyword: Packet filtering; DOCA Flow |
|
|
Detected in version: 3.1.0 |
|
|
4627850 |
Description: The RTC timestamp is not correctly parsed in the doca_telemetry_diag sample. |
|
Keyword: RTC; PTP; DOCA Telemetry |
|
|
Detected in version: 3.1.0 |
|
|
4548383 |
Description: The
|
|
Keyword: DOCA Flow |
|
|
Detected in version: 3.1.0 |
|
|
4560966 |
Description: Enabling the RX Rate flag in the ZTR RTTCC algorithm causes compilation to fail because the private DOCA PCC device header is not included. |
|
Keyword: DOCA PCC; Zero-touch RoCE; round-trip time congestion control |
|
|
Detected in version: 3.1.0 |
|
|
4223392 |
Description: CT miss pipe receives configured IP version only. |
|
Keyword: DOCA Flow |
|
|
Detected in version: 3.1.0 |
DOCA-Host and DOCA Drivers Bug Fixes
|
Ref # |
Issue |
|---|---|
|
4539156 |
Description: Fixed an issue on Debian/Ubuntu where DKMS kernel modules post-install scripts did not set autoinstall, causing modules to appear as "added" instead of "installed". |
|
Keyword: DKMS kernel modules, Debian/Ubuntu, post-install scripts |
|
|
Detected in version: 3.1.0 |
|
|
4548661 |
Description: Resolved startup warning in MFT caused by missing dimax-init component, which was not included in the EN+RoCE Bundle. |
|
Keyword: MFT |
|
|
Detected in version: 3.1.0 |
|
|
4578268 |
Description: Resolved missing kernel symbol dependencies in kmod-* packages by switching to DKMS-based modules in DOCA Host 3.2.0, ensuring proper module load on custom kernels. |
|
Keyword: kmod-* packages, DKMS-based modules |
|
|
Detected in version: 3.1.0 |
|
|
4648210 |
Description: Fixed an issue preventing DNF/YUM upgrades of rebuilt mlnx-ofa_kernel-devel packages (via doca-kernel-support) due to version sorting errors. The rebuilt package now appends ".1" and the kernel version to ensure proper RPM comparison and smooth upgrades. |
|
Keyword: mlnx-ofa_kernel-devel package |
|
|
Detected in version: 3.1.0 |
|
|
4651525 |
Description: Fixed an issue on ARM64 systems where the write-combining capability might not have been properly detected during driver initialization.
|
|
Keyword: Firmware, kernel lock |
|
|
Detected in version: 3.1.0 |
|
|
4642754 |
Description: Fixed a non-responsive firmware issue that could cause the kernel to lock up for an extended period. |
|
Keyword: Firmware, kernel lock |
|
|
Detected in version: 3.1.0 |
|
|
4567695 / 4606693 |
Description: Fixed a rare crash that could occur when a MAD completion queue (CQ) was destroyed while RDMA CM traffic was still active. |
|
Keyword: MAD CQ |
|
|
Detected in version: 3.0.0 |
|
|
4222720 |
Description: Fixed an issue where, when running on DPU Arm cores, |
|
Keyword: DOCA Firefly Service |
|
|
Detected in version: 3.1.0 |
|
|
4553499 |
Description: Fixed an issue where, on devices that do not support BlueFlame, allocation of a new Transport Domain (TD) could fail when attempting to allocate a dedicated UAR. |
|
Keyword: BlueFlame, Transport Domain (TD), UAR |
|
|
Detected in version: 3.0.0 |
BSP Bug Fixes
|
Ref # |
Details |
|---|---|
|
4693948 |
Description: When attempting to install the Ubuntu 24.04 (64k kernel) BFB image directly to an EMMC device, the installation may fail with a kernel panic. The system logs indicate an inability to mount the root filesystem, specifically returning the error: |
|
Keywords: VFS; kernel panic; EMMC installation |
|
|
Detected in version: 4.14.0 |
|
|
4923234 |
Description: The |
|
Keywords: Target offload; BFB image |
|
|
Detected in version: 4.14.0 |
|
|
4948318 4945554 |
Description: If a secondary BMC task (such as a log dump) is started after the BMC firmware update has been initiated, but before the installer's monitoring logic has attached to it, the installer may mistakenly track the secondary task. This tracking error causes the installer to misjudge the update's completion, which can cause the subsequent BMC reboot to fail and leave the new firmware in a pending, unactivated state. |
|
Keywords: BFB installer; Redfish API; task monitoring |
|
|
Detected in version: 4.14.0 |
|
|
4863927 |
Description: When attempting to install development packages via |
|
Keywords: gcc; gcc-c++; dnf |
|
|
Detected in version: 4.14.0 |
|
|
4988092 |
Description: Following an out-of-the-box installation and subsequent reboot on Ubuntu 24.04 (64k kernel), the |
|
Keywords: Network Manager; systemd; timeout |
|
|
Detected in version: 4.14.0 |
|
|
4893340 |
Description: A strict 128KB maximum size limit for the |
|
Keywords: BFB installation; file size limit; bf.cfg |
|
|
Detected in version: 4.14.0 |
|
|
4849953 |
Description: The |
|
Keywords: DPA; missing package |
|
|
Detected in version: 4.14.0 |
|
|
4871396 |
Description: The |
|
Keywords: DPA; missing package |
|
|
Detected in version: 4.14.0 |
|
|
4907434 |
Description: When a BMC firmware update requires activation (and is the only component pending), the |
|
Keywords: BMC firmware; pending activation |
|
|
Detected in version: 4.14.0 |
|
|
4907646 |
Description: When using the |
|
Keywords: Automation; interactive prompt |
|
|
Detected in version: 4.14.0 |
|
|
4879150 |
Description: Running the |
|
Keywords: Scalable functions; mlnx-sf; eswitch; mlxdevm |
|
|
Detected in version: 4.14.0 |
|
|
4776492 |
Description: Occasionally, upgrading PLDM BFB from DOCA v3.2.0 to v3.2.1 may lead to an assert 0x7 in dmesg. |
|
Keywords: PLDM |
|
|
Detected in version: 4.14.0 |
|
|
4949639 |
Description: During a BFB installation, the CEC firmware updates successfully, but the completion confirmation message is missing from the RSHIM logs. The log displays "Updating CEC firmware" but omits the final success status before moving on to the next installation step (such as updating certificates). |
|
Keywords: RShim logs; CEC firmware |
|
|
Detected in version: 4.14.0 |
|
|
4836088 |
Description: Executing |
|
Keywords: Secure boot; ASCII conversion; BOOTx_DEVPATH |
|
|
Detected in version: 4.14.0 |
|
|
4839828 |
Description: Host |
|
Keywords: MAC address; tmfifo_net; rshim |
|
|
Detected in version: 4.14.0 |
|
|
4924237 |
Description: The RShim USB device may intermittently disappear from the DPU BMC, causing operations that rely on it to fail with a "Failed to enable BMC rshim" error. |
|
Keywords: RShim USB; out-of-band update |
|
|
Detected in version: 4.14.0 |
|
|
4658222 |
Description: During the DPU boot-up sequence, an intermittent call trace containing the warning |
|
Keywords: Call trace; kernel boot up |
|
|
Detected in version: 4.14.0 |
|
|
4604090 |
Description: If a corrupted or unauthenticated BFB image is transferred from the BMC to the DPU, the system halts the installation process as part of a built-in security mechanism. Once triggered, the recovery path remains locked to prevent potential compromise. |
|
Keywords: Corrupt; BFB |
|
|
Detected in version: 4.14.0 |
|
|
4848119 |
Description: A BlueField-2 UEFI boot-time regression added approximately 20 seconds to system startup. |
|
Keywords: BlueField-2; boot time; UEFI |
|
|
Detected in version: 4.14.0 |
|
|
4904043 |
Description: An intermittent firmware assert error ( |
|
Keywords: PLDM |
|
|
Detected in version: 4.14.0 |
BMC Bug Fixes
|
Ref # |
Issue Details |
|---|---|
|
4944048 |
Description: When upgrading or downgrading between the 25.10-LTSU2 and 26.04 releases, repeated BMC reboots may, in rare cases, cause the |
|
Workaround: Perform a factory reset on the BMC. |
|
|
Keyword: BMC reboot; core dump; factory reset |
|
|
Reported in version: 25.10-LTSU2 |
|
|
4917779 |
Description: Initiating an Arm |
|
Reported in version: 26.01 |
|
|
4948318 4945554 |
Description: If a secondary BMC task (such as a log dump) is started after the BMC firmware update has been initiated, but before the installer's monitoring logic has attached to it, the installer may mistakenly track the secondary task. This tracking error causes the installer to misjudge the update's completion, which can cause the subsequent BMC reboot to fail and leave the new firmware in a pending, unactivated state. |
|
Reported in version: 26.01 |
|
|
4401488 |
Description: The BMC kernel enforces |
|
Reported in version: 26.01 |
|
|
4905017 |
Description: When operating in NIC mode, a host power cycle may intermittently cause the UEFI to fail to retrieve BMC Redfish credentials. This results in a |
|
Reported in version: 26.01 |
|
|
4969243 |
Description: When the |
|
Reported in version: 26.01 |
|
|
4995032 |
Description: Redfish queries via |
|
Reported in version: 26.01 |
|
|
4867786 |
Description: During BFB installation, the Golden ARM image update may intermittently hang and fail via Redfish, logging a |
|
Reported in version: 26.01 |
|
|
4914053 |
Description: The BFB installer defaults to DHCP for the VLAN4040 interface. If no DHCP server is present, the request silently fails after a 300-second timeout, bypassing the static IP fallback and skipping all BMC-related firmware updates. |
|
Reported in version: 26.01 |
|
|
4924426 |
Description: Following a DPU reset, the |
|
Reported in version: 26.01 |
|
|
4987307 |
Description: During BFB installations via Redfish, the task state may change to "Exception" before the specific error message is appended to the HTTP response payload. This results in incomplete error logs on the initial poll following a failure. |
|
Reported in version: 26.01 |
|
|
4980118 |
Description: The |
|
Reported in version: 26.01 |
|
|
4799519 |
Description: Accessing the |
|
Reported in version: 26.01 |
|
|
4932328 |
Description: Excessive Common Platform Error Record (CPER) files in |
|
Reported in version: 26.01 |
|
|
4957197 |
Description: When external monitoring tools or scripts repeatedly query the BMC's Redfish interface using Basic authentication over extended periods, internal session resources fail to release properly. This memory leak eventually causes the BMC to lose network connectivity, even while the DPU management interface remains online. |
|
Reported in version: 26.01 |
|
|
4966472 |
Description: The BMC generates a warning log for PLDM_Sensor_1_100 when the NIC temperature reaches the official 91°C upper non-critical threshold. This is an expected hardware alert for elevated temperatures, not a software defect. |
|
Reported in version: 26.01 |
BlueField-3 Firmware Bug Fixes
|
Internal Ref. |
Issue |
|---|---|
|
4570205 |
Description: Fixed a firmware issue where the ZTR_RTTCC algorithm parameters AI and HAI did not support a sufficient range. |
|
Keywords: PCC, ZTR_RTTCC |
|
|
Detected in version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4650314 |
Description: The SBR hot reset error during mlxfwreset level 4 is resolved by skipping configuration of the second (disabled) link via mlxconfig. With only the active link configured, the reset flow completes successfully. |
|
Keywords: mlxfwreset |
|
|
Detected in version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4629077 |
Description: Fixed an issue where coalescing regular SX events with SX RTT events under ZTR_RTTCC could keep improper event fields, which could impact congestion control behavior. |
|
Keywords: PCC, ZTR_RTTCC |
|
|
Detected in version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4683328 |
Description: Fixed an issue in the ZTR_RTTCC algorithm where probe-abortion handling could behave improperly under high-stress network conditions, ensuring proper congestion control and stable traffic performance. |
|
Keywords: PCC, ZTR_RTTCC |
|
|
Detected in version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4501554 |
Description: Fixed an assertion failure that could occur with the E-Switch uplink in specific configurations where the e-switch was disabled and Path Migration was active or GVMIs were using SRQ loopback in SQs. The issue occurred because the firmware attempted to perform cleanup operations when the uplink configuration lacked sufficient capacity.
|
|
Keywords: Path migration, steering |
|
|
Detected in version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4506854 |
Description: Added Scaling Factor "read" field. To obtain correct values in mlxlink, MFT version 4.33.0 or later is required. |
|
Keywords: Scaling Factor, mlxlink, MFT |
|
|
Detected in version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4500365 |
Description: Fixed the adaptive PCIe gain setting. |
|
Keywords: PCIe gain |
|
|
Discovered in Version: 32.43.2402 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4571079 |
Description: Fixed an issue where invoking the resourcedump tool with segment type DPA_PROCESS_LST returned invalid data when the parameter n1 == 1 and no processes existed on the current vhca_id.
|
|
Keywords: DPA PROCESS, RESOURCE DUMP |
|
|
Discovered in Version: 32.45.1020 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4529293 |
Description: Fixed an issue where, during failover or restart, the SM sending a PortInfo MAD to the HCA firmware triggered reinitialization of port buffers, momentarily halting ingress traffic and causing packet drops.
|
|
Keywords: OpenSM |
|
|
Discovered in Version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4683346 |
Description: Fixed an issue where, under the ZTR_RTTCC algorithm, a flow that reached its minimum rate due to heavy congestion would not recover its rate once the congestion cleared. |
|
Keywords: PCC, ZTR_RTTCC |
|
|
Discovered in Version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4458670 |
Description: Fixed an issue where writing to nic_interface could set the parent function to DISABLED without propagating the state to its child VFs. The firmware now ensures that children inherit the DISABLED state correctly. |
|
Keywords: VF health |
|
|
Discovered in Version: 32.45.1020 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4517037 |
Description: Fixed a rare issue where performing an FLR on a released ICM address from the DPA process could cause the DPA kernel to hang due to a race condition. |
|
Keywords: FLR, ICM address |
|
|
Discovered in Version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4618972 |
Description: Fixed an issue that could cause false-positive detection of DEAD_IRISC during DPA destroy_process or destroy_mem operations on highly loaded systems. |
|
Keywords: IRISC |
|
|
Discovered in Version: 32.43.2402 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4133425 |
Description: Fixed an issue where PTP was not supported when the port speed was configured to 1G. |
|
Keywords: PTP
|
|
|
Discovered in Version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
|
|
4500507 |
Description: Fixed an issue where parallel execution of CREATE_NVME_SQ or CREATE_NVME_SQ_BE objects could lead to a fatal assert (0x8184). |
|
Keywords: NVME, CREATE_NVME_SQ, CREATE_NVME_SQ_BE
|
|
|
Discovered in Version: 32.46.1006 |
|
|
Fixed in Release: 32.47.1026 |
BlueField-2 Firmware Bug Fixes
|
Internal Ref. |
Issue |
|---|---|
|
4501554 |
Description: Fixed an assertion failure that could occur with the E-Switch uplink in specific configurations where the e-switch was disabled and Path Migration was active or GVMIs were using SRQ loopback in SQs. The issue occurred because the firmware attempted to perform cleanup operations when the uplink configuration lacked sufficient capacity.
|
|
Keywords: Path migration, steering |
|
|
Discovered in Version: 24.46.1006 |
|
|
Fixed in Release: 24.47.1026 |
|
|
4529293 |
Description: Fixed an issue where, during failover or restart, the SM sending a PortInfo MAD to the HCA firmware triggered reinitialization of port buffers, momentarily halting ingress traffic and causing packet drops.
|
|
Keywords: OpenSM |
|
|
Discovered in Version: 24.45.1020 |
|
|
Fixed in Release: 24.47.1026 |
|
|
4366117 |
Description: Configuring a small MTU leads to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discard these packets, causing the PXE boot to fail. |
|
Keywords: PXE boot filters |
|
|
Discovered in Version: 24.45.1020 |
|
|
Fixed in Release: 24.47.1026 |
Last updated: