This guide explains how to configure DPU Virtual Functions (VFs) in a DPF Host Trusted environment.
The examples below configure 20 VFs per host Physical Function (PF) and 8 VFs per DPU Embedded CPU Physical Function (ECPF) in firmware, and create 8 DPU VFs on port p0. Adjust these values for your environment. For supported VF counts and hardware limits, see the NVIDIA BlueField SR-IOV documentation.
Schedule a maintenance window for a manual host power cycle after configuring the host PFs. A host power cycle resets the BlueField device and interrupts both host and DPU workloads. Rebooting only the DPU OS does not apply these firmware settings. Follow your platform's BlueField reset and reboot procedures.
Why Manual Host Configuration Is Required
Enabling VFs on the DPU ECPF requires enabling per-function VF limits in firmware (PF_NUM_OF_VF_VALID=1). When per-function limits are enabled, the firmware ignores the global NUM_OF_VFS parameter and requires PF_NUM_OF_VF to be set individually on the DPU ECPF and on each host PF.
spec.nvconfig in a DPUFlavor runs on the DPU and applies PF_NUM_OF_VF only to the DPU ECPF. Until DPF supports applying host firmware settings through spec.hostNetworkInterfaceConfigs[].nvconfig, you must configure PF_NUM_OF_VF on the host PFs manually.
Prerequisites
-
A physical BlueField in DPU mode, managed by DPF in Host Trusted mode (DOCA 3.5.0 or later on the DPU).
-
Administrative access to the host, DPU, management cluster, DPU cluster, and host power controls.
-
mlxconfiginstalled on the host or available through the DPFhostagentcontainer.
1. Configure the DPUFlavor
Merge the following settings into your DPUFlavor, keeping your existing configuration. If your flavor already has a wildcard (device: '*') entry under spec.nvconfig, append these parameters to that entry instead of adding a second one.
spec:
nvconfig:
- device: "*"
force: true
parameters:
- SRIOV_EN=1
- NUM_OF_VFS=20
- PF_NUM_OF_VF_VALID=1
- PF_NUM_OF_VF=8
virtualFunctions:
- device: p0
count: 8
poolName: bf_vf
-
device: '*'andforce: true: Applies the firmware settings to both ports on the DPU.force: trueis required becausePF_NUM_OF_VFis hidden in firmware untilPF_NUM_OF_VF_VALID=1is active (see Forcing parameters that firmware hides). -
PF_NUM_OF_VF_VALID=1andPF_NUM_OF_VF=8: Enables per-function VF limits and sets the DPU ECPF limit to 8 VFs per port. -
NUM_OF_VFS=20: Retained because the DPF host agent readsNUM_OF_VFSfrom the flavor to determine how many host VFs to create in sysfs, even though firmware now usesPF_NUM_OF_VFfor the actual limit. -
virtualFunctions: Creates 8 DPU VFs onp0and exposes them in the DPU cluster asnvidia.com/bf_vf, matching the resource requested by a DPUServiceNAD withresourceType: vf.
Setting spec.virtualFunctions disables automatic Scalable Function (SF) inference from PF_TOTAL_SF. If your workloads also use SFs, explicitly declare them under spec.scalableFunctions in the same DPUFlavor (see Function counts and the firmware budget).
Provision or reprovision the DPU with this flavor. Wait until DPU provisioning applies the NVConfig settings and completes the required host power cycle. Note that provisioning may wait in the Host Network Configuration phase until you complete the host configuration below.
2. Configure the Host VF Limits
On each required host PF, enable per-function VF limits (PF_NUM_OF_VF_VALID=1) and set the host VF limit (PF_NUM_OF_VF=20). Until these settings are applied and activated, the host's sriov_numvfs sysfs entry may be absent.
-
On the host, identify the BlueField host PCI addresses (for example,
0000:89:00.0and0000:89:00.1):
lspci -D | grep -i mellanox
Host and DPU PCI bus addresses differ. Make sure you use the PCI addresses discovered on the host.
-
Apply the firmware settings to each host PF using either of the following methods (replace
0000:89:00.0and0000:89:00.1with your host PCI addresses): -
Directly on the host:
Bashsudo mlxconfig -d 0000:89:00.0 -y s PF_NUM_OF_VF_VALID=1 PF_NUM_OF_VF=20 sudo mlxconfig -d 0000:89:00.1 -y s PF_NUM_OF_VF_VALID=1 PF_NUM_OF_VF=20 -
From the management cluster via the
hostagentcontainer:Bashkubectl -n dpf-operator-system exec "<hostagent-pod-name>" \ -c hostagent -- mlxconfig -d 0000:89:00.0 -y s PF_NUM_OF_VF_VALID=1 PF_NUM_OF_VF=20 kubectl -n dpf-operator-system exec "<hostagent-pod-name>" \ -c hostagent -- mlxconfig -d 0000:89:00.1 -y s PF_NUM_OF_VF_VALID=1 PF_NUM_OF_VF=20
Perform a host power cycle (including a BlueField device reset) to activate the host firmware settings. Wait for both the host and the DPU to boot and become reachable.
3. Create the Host VFs
After the host boots, verify whether DPF has already created the host VFs. If not, create them using one of the following options:
-
Option A — Restart the host-agent pod (recommended): From the management cluster, delete the host-agent/DMS pod using the target host's node name and the host-agent component label. DPF recreates the pod, which automatically configures the host VFs using
NUM_OF_VFSfrom the DPUFlavor:
kubectl -n dpf-operator-system delete pod --field-selector "spec.nodeName=<host-node-name>" \
-l provisioning.dpu.nvidia.com/component=hostagent
-
Option B — Manually on the host: Write the VF count directly to
sriov_numvfsfor each host PF:
echo 20 | sudo tee /sys/bus/pci/devices/0000:89:00.0/sriov_numvfs
echo 20 | sudo tee /sys/bus/pci/devices/0000:89:00.1/sriov_numvfs
4. Verify the DPU VFs
Once DPU provisioning completes, verify that the DPU node advertises the VF resource in the DPU cluster:
kubectl describe node "<dpu-node-name>"
Confirm that both Capacity and Allocatable include nvidia.com/bf_vf: 8.
Last updated: