This is the GA release of the DOCA Platform Framework (DPF). It includes bug fixes and improvements to enhance the provisioning and orchestration of NVIDIA BlueField DPUs in Kubernetes environments.
Revision History
|
Date |
Description |
|---|---|
|
November 2026 |
General Availability (GA) release of DOCA Platform Framework v30.0.0 |
Features
-
In-place DPU reconfiguration
-
A new CRD and flow reconfigure a provisioned DPU without reprovisioning it. A round is started from an annotation on the
DPUSet, runs the DPU through Node Effect to DPU Config and re-runs the DPU agent when the phase returns to DPU Config. -
The DPU agent fetches the live
DPUFlavor, so flavor changes are picked up during a round. -
A round respects
maxUnavailableDPUNodes.
-
-
Consolidated PKI
-
The provisioning CA is collapsed into the platform CA, and the provisioning leaves are signed by the platform CA.
-
The platform CA can be anchored in a configurable issuer and rotated without a pin. The trust bundle is left to whoever owns the CA.
-
The webhook certificates chain to a single DPF root CA.
-
See the documentation on switching to your own authority and on rotating a self-signed CA.
-
-
SPIFFE workload identity
-
Builds on the SPIFFE identity introduced in v26.8.0. The SPIFFE CSI driver can be deployed to DPU clusters and its images can be overridden.
-
DPUServices can opt in to register SPIFFE workload identities, and the DPU agent identities are templated and restricted with hardened selectors.
-
Kubernetes workload attestation is enabled on the DPUs that use SPIFFE.
-
A DSX SPIFFE Helper is available.
-
Limits:
-
SPIFFE is opt-in through
DPFOperatorConfig.spec.security.spiffeand needs a pre-installed SPIRE deployment. Nothing changes on upgrade unless it is enabled. -
It is available in Zero Trust deployments only.
-
It applies to newly provisioned DPUs only. Existing DPUs stay in bootstrap-token mode even after SPIFFE is enabled, and a cluster can hold a mix of both. DPF skips bootstrap-token DPUs when registering DPUService identities, so DPUServices on those DPUs do not receive one until the DPU is reprovisioned.
-
-
For setup, see SPIFFE Workload Identity.
-
-
DPUFlavor
-
spec.scalableFunctionsandspec.virtualFunctionsdeclare SR-IOV function groups, andspec.dma.enabledenables the DMA SF. The DPU agent creates the functions and generates the configuration of the SR-IOV device plugin. -
The container sandbox image can be overridden and the immutability of a
DPUFlavoris enforced per field. -
See the guide for configuring DPU Virtual Functions.
-
-
DPU provisioning
-
Fewer reboots in the DPU provisioning flows.
-
DPU provisioning is held while a DPF upgrade is in progress.
-
A new service readiness phase gates the DPU on the readiness of its DPUServices.
-
BMC hardening: factory reset and password hardening, rotation of the BMC server certificate and mTLS is re-established when the BMC IP of a
DPUDevicechanges. -
Firmware: PLDM firmware bundles per PSID, recovery of BlueField-4 PLDM updates and an annotation to force a firmware update.
-
The DPU Arm boot progress is reported in Zero Trust while the OS is installing, and the host clock is adopted over tmfifo in Host Trusted mode.
-
The DPU controller supports opt-in concurrent workers.
-
-
Networking and service chaining
-
IPv6 IPAM, including the IPAM API.
-
ServiceInterfaceSetobjects are migrated toNodeServiceInterfaceson reconcile, andNSIPathForSFCis enabled by default. -
A new link-state-propagation service.
-
The DPU cluster DNS is served from the host cluster, and the standard CNI plugins are installed on the DPU.
-
-
Storage
-
A CMX initiator DPUService component.
-
MEMOS KV volumes are exposed on SNAP, and each SNAP volume gets its own NVMe subsystem.
-
IPv6 NVMe targets are supported.
-
-
Distributed tracing with OpenTelemetry
-
DPF controllers export trace spans for their reconcile loops. One change of a top-level object, such as a
DPUDeployment, is one trace that joins the reconciles of the object and of everything it creates. -
An upstream caller can set the
tracing.k8s.io/traceparentandtracing.k8s.io/tracestateannotations on the objects it creates, so a single request can be followed across the DPF controllers. Without them DPF derives the trace from the UID and generation of the object. -
The orchestration, provisioning (including Redfish HTTP calls) and SDN controllers (
sfc-controller,pod-ipam-injector) are instrumented. -
Tracing is disabled by default.
DPFOperatorConfig.spec.monitoring.tracing.otlp.endpointis the destination of the controllers in the Host Cluster andspec.monitoring.openTelemetryCollector.tracing.endpointthe destination of the DPU clusters. A Tempo backend is supported. -
See Tracing for the configuration and for how to set the trace context.
-
-
DPU OpenTelemetry collector
-
The collector accepts a full custom configuration and TLS endpoints.
-
Only the signals that have an endpoint configured are exported.
-
-
DPFOperatorConfig
-
The default DaemonSet
maxUnavailableis configurable. -
Usage of deprecated fields is reported in the status.
-
deploymentModeis immutable after creation.
-
-
Air gap
-
Tooling, a SOCKS proxy guide and a bill of materials for air-gapped installations.
-
-
Platform
-
The DPUCluster Kubernetes version is bumped to v1.36.5.
-
Blueman is no longer supported by DPF.
-
Fixed Issues from Previous Release
-
Stale ports after DPU reboot
-
Stale OVS ports are deleted by UUID instead of by name, so a leftover port no longer causes duplicated traffic after a DPU reboot or power cycle.
-
Internal Ref #4174183, #5361112
-
-
[Zero Trust] Manual change of DPU mode from DPU to NIC after DPU discovery causes provisioning to stall in Rebooting
-
Provisioning no longer remains stuck in the
Rebootingphase after the DPU mode was changed manually after discovery. -
Internal Ref #4984034
-
-
OS installation failure after a leader switch of the provisioning controller (Zero Trust)
-
In Zero Trust, the
bfb-registryhost and NodePort that are baked into the DPU configuration stay stable across a leader failover of the provisioning controller or an upgrade, so DPU OS downloads keep passing TLS verification. This is still a known issue for Host Trusted deployments. -
Internal Ref #4957820
-
-
BMC account lockout
-
The password from the secret is tried before falling back, which avoids locking the account.
-
-
Security
-
CVE fixes in the Go toolchain, nginx, gRPC, oras-go, x/mod, x/text, the attacher etcd client (GO-2026-6107) and the VPC components.
-
Supported DPU Services
The support status of each service is unchanged compared to v26.8.0, except for the following:
-
The CMX initiator and the link-state-propagation service are new.
-
Blueman is no longer supported.
Dependencies
-
Supported DOCA BFB Image (BlueField-3):
-
bf-bundle-3.6.0 -
See the DPF Compatibility Policy and Platform Support for the full support window.
-
Installation & Upgrade Notes
Installation Notes
None.
Upgrade Notes
-
Existing
DPUFlavorobjects keep working. Flavors without function groups still derive their Scalable Functions fromPF_TOTAL_SFand the trusted SF annotation. -
DPU provisioning is held while the upgrade is in progress, so new DPUs start provisioning once the upgrade completes.
Known Issues and Limitations
-
Socket Direct environments are not supported
-
DPF does not currently support environments where NVIDIA Mellanox Socket Direct adapters are used. Socket Direct is a network adapter architecture that provides direct PCIe access from multiple CPU sockets to a single NIC, bypassing the inter-processor bus. DPUs in Socket Direct configurations are not tested or validated with DPF.
-
For more details, see Platform Support - Limitations.
-
-
DPU Cluster control-plane connectivity is lost when physical port P0 is down on the worker node
-
Link down of p0 port on the DPU will result in DPU control plane connectivity loss of DPU components.
-
Internal Ref #3751863
-
Workaround: Make sure P0 link is up on the DPU, if down either restart DPU or refer to DOCA troubleshooting https://docs.nvidia.com/networking/display/bfswtroubleshooting. Note: This issue is relevant for Host Trusted deployments only.
-
-
System doesn't recover after DPU Reset
-
When the user triggers a reset of a DPU in any way other than using DPF APIs (e.g. recreation of a DPU CR), the system may not recover.
-
Internal Ref #4521178, #4732664
-
Workaround: Power cycle the host. Note that this operation is dangerous and there might be file system corruption which will require triggering the reprovisioning of the DPU. If the system does not recover, reprovision the DPU by deleting the DPU CR (it will be recreated and DPU provisioning will happen). Note: This issue is relevant for Host Trusted deployments where OVN-Kubernetes is used as a primary CNI.
-
-
Leftover CRs if worker is removed from the cluster permanently
-
When a worker was added to a cluster, optionally had DPU provisioned and later was removed from the host cluster permanently, there may be leftover DPF related CRs in both the host cluster and the DPU cluster.
-
Internal Ref #4403130
-
Workaround: No workaround, known issue.
-
-
DPUService stops reconciling when DPUCluster is unavailable for long time
-
When the DPUCluster is unavailable for long time (more than 5 mins), changes to DPUServices (also generated ones via DPUDeployment or DPFOperatorConfig) that have happened during that time might not be reflected to the DPUCluster.
-
Internal Ref #4359857
-
Workaround: Recreate DPUServices that are stuck.
-
-
[OVN-Kubernetes DPUService] Lost traffic from workloads to control plane components or Kubernetes services after dpu reboot, port flapping, ovs restart or manual network configuration
-
Connectivity issues between workload pods to control plane components or Kubernetes services may occur after the following events: DPU reboot without host reboot, high speed port flapping (link down/up), ovs restart, DPU network configuration change (for example using "netplan apply" command on DPU). The issues are caused by network configuration that was applied by ovn CNI on DPUs and won't get reapplied automatically.
-
Internal Ref #4521178
-
Workaround: Recreate the OVN-Kubernetes node pod on the host to reapply the configuration.
-
-
[OVN-Kubernetes DPUService] No network connectivity for SR-IOV accelerated workload pods after DPU reboot
-
SR-IOV accelerated workload pod is losing its VF interface upon DPU reboot. VF is available on the host however not injected back into the pod.
-
Internal Ref #4236521
-
Workaround: Recreate the SR-IOV accelerated workload pods.
-
-
[Firefly DPUService] Deletion of the Firefly DPUService leaves stale flows in OVS
-
When the Firefly DPUService is deleted after successful deployment or the labels of the serviceDaemonSet are modified, flows are not cleaned up from OVS.
-
Internal Ref #4382535
-
Workaround: Although these flows are very unlikely to cause an issue, reprovisioning the DPU or power cycling the host will bring the OVS in good state. Note that power cycling the host is dangerous and there might be file system corruption which will require triggering the reprovisioning of the DPU.
-
-
[DPUDeployment] Pods of service referenced in spec.serviceChain are restarted when serviceChain changes, causing disruption
-
When updating DPUDeployment.spec.serviceChain with a disruptive upgrade, the affected pods are restarted but DPUDeployment removes the node effect from the corev1.Node in the host cluster proactively. This causes the node to be marked as ready and accept workloads before DPU services are fully operational.
-
Internal Ref: #4686635
-
Workaround: No workaround, known issue.
-
-
Long DPU provisioning time when multiple DPUs are provisioned on the same node
-
In some cases, it may take a long amount of time to provision multiple DPUs on the same node.
-
Internal Ref: #4757191
-
Workaround: If the DPU is stuck in
DPU Cluster Configphase after a long installation, please reprovision the DPU and make sure no other DPUs on the same node are being provisioned at the same time
-
-
[DPUDeployment] DPU does not recover to Ready after Node Effect Removal timeout, even when service configuration is reverted
-
When a DPUDeployment is deployed and becomes ready, and then a service is updated with an invalid configuration (e.g. overriding the image with a wrong one in DPUServiceConfiguration), the DPU enters the Node Effect Removal state. If the Node Effect Removal timeout is exceeded, the DPU transitions to Error state. Even after reverting the DPUServiceConfiguration to the previous valid configuration, the DPU does not move back to Ready. The
nodeEffectRemovalTimeoutinDPFOperatorConfig.spec.provisioningControllerdefaults to0s(disabled), meaning this issue will not occur with the default configuration. If the timeout is explicitly set to a non-zero value (e.g.30m), ensure the configured duration allows sufficient time for configuration corrections before the DPU transitions to Error state. -
Internal Ref: #4952676
-
Workaround: Revert to a working configuration and delete the DPU CR to trigger reprovisioning.
-
-
Leader switch of the provisioning controller pod while the DPU is in the middle of deploying may cause OS installation failure (Host Trusted)
-
When deploying a DPU without
bfbPVCNameprovided in the DPFOperatorConfig, a leader switch in the DPU provisioning controller (for any reason) during the provisioning process may cause the DPU to transition to theErrorphase due to download failures of the BFB or bfb.cfg during OS installing. This issue produces anOSInstalledcondition (InstallationTerminatedreason) in the host-trusted environment. It is fixed for Zero Trust deployments. -
Internal Ref: #4957820
-
Workaround: Delete the DPU CR to trigger reprovisioning.
-
-
DOCA SNAP may fail to reattach a DPUVolumeAttachment that uses VirtioFS or emulated NVMe devices on hot-plugged PFs after a host power cycle
-
After a host power cycle, a DPUVolumeAttachment that uses VirtioFS or emulated NVMe devices on hot-plugged PFs can become not ready and might not be restored automatically.
-
Internal Ref: #4734537
-
Workaround:
-
Step 1: Delete failed DPUVolumeAttachment.
-
Step 2: Create a new DPUVolumeAttachment with the same configuration.
-
-
-
DPU can remain stuck in DPU Config when a DPUFlavor adds a ConfigMap during OS installation
-
If a DPU has passed
Prepare BFBand itsDPUFlavoris updated during OS installation with an agent-appliedconfigFilesentry that references a new ConfigMap, the DPU agent reads the updated flavor but its Role is not refreshed with permission to read that ConfigMap. The read is rejected as forbidden, the agent does not report a reboot method, and the DPU remains inDPU Configwith theDPUConfig=Falsecondition andWaitingForRebootMethodreason. -
Internal Ref: #5409290
-
Workaround: Add all agent-applied ConfigMap references to the
DPUFlavorbefore the DPU enters OS installation. If a DPU is already affected, add the ConfigMap name to theresourceNamesof the correspondingda-<dpu-name>Role so that the next DPU agent retry can continue. Alternatively, reprovision the DPU after finalizing the flavor.
-
-
Single-port BlueField-4 is not supported
-
DPF v30.0.0 supports only the dual-port BlueField-4. The single-port BlueField-4 is not tested or validated with this release.
-
Internal Ref: #5416479
-
Workaround: No workaround. Use a dual-port BlueField-4.
-
Last updated: