Zero Trust BMC RShim troubleshooting (BlueField-3)
In Zero Trust provisioning, DPF disables host RShim and enables BMC RShim through Redfish during Config FW Parameters, then waits for BmcRShimEnabled=true before preparing the BFB.
Symptoms
The DPU stays in Config FW Parameters. The FWConfigured condition shows one of:
|
Reason |
Meaning |
|---|---|
|
|
BMC RShim was requested once; waiting up to 10 minutes. |
|
|
The DPU Arm did not power on within 5 minutes of a one-shot Arm ForceRestart. |
|
|
As above, with |
|
|
The Arm is powered but BMC RShim is still disabled 10 minutes after the request. |
The last three also set the FWBMCRShimStalled condition, raise a Warning event and fire the DPFDPUBMCRShimStalled alert. The DPU is not moved to Error: provisioning continues automatically once the DPU is recovered.
Diagnose
-
Collect a BMC dump first (
dpfctl dump, see Diagnostic Dumps). -
Redfish ComputerSystem: check
PowerState,Status.State,BootProgress.OemLastState. -
Redfish
Managers/Bluefield_BMC/Oem/Nvidia: checkBmcRShim.BmcRShimEnabled. -
On the BMC:
systemctl status rshimandls /dev/rshim*.
HostRshim=Disabled and BmcRShimEnabled=true do not prove that /dev/rshim0 is usable; only the USB attachment does.
Recover
For the LowPowerStandby signature, the validated recovery is a chassis power reset on the DPU BMC:
ipmitool chassis power reset
This is disruptive. Collect diagnostics first and do not script it without guards.
Last updated: