NVIDIA NVOS User Manual for InfiniBand Switches

Control and Power Commands

nv show system reboot


nv show system reboot

Show system reboot information.

Syntax Description

N/A

Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show system reboot

           operational                          applied
---------  -----------------------------------  -------
[history]                                                
reason
  gentime  2022_06_02_07_32_05                           
  reason   Hardware - Other (Reset from ComEx)           
  user     N/A                                           

REST API

GET https://<ip>/nvue_v1/system/reboot

Related commands


Notes


nv show system reboot reason


nv show system reboot reason

Show the system reboot reason.

Syntax Description

N/A

Default

N/A

History

25.02.2002 


25.02.8008

Added reason-type field

Example

admin@nvos:~$ nv show system reboot reason 
                 operational 
-------          ------------------- 
reason           warm-reboot 
gentime          2026-03-09 08:18:56 
user             admin 
reason-type      user-initiated           

REST API

GET https://<ip>/nvue_v1/system/reboot/reason

Related commands


Notes


nv show system reboot history


nv show system reboot history

Show the system reboot history.

Syntax Description

N/A

Default

N/A

History 

25.02.2002 


25.02.8008

Added reason-type field

Example

admin@nvos:~$ nv show system reboot history 

   gentime              reason                  user    reason-type    
-  -------------------  ------                  -----   --------------   
1  2026-03-10 11:17:43  reboot                  admin   user-initiated 
2  2026-03-10 09:56:22  insufficient fan speed  admin   critical-error   
3  2026-03-10 07:47:23  reboot                  admin   user-initiated 

REST API

GET https://<ip>/nvue_v1/system/reboot/history

Related commands


Notes


nv show system reboot counters


nv show system reboot counters

Show the number of reboots of different types (grouped by the openconfig defined types from  COMPONENT_REBOOT_REASON).

Syntax Description

N/A

Default

N/A

History

25.02.8008

Example

admin@nvos:~$ nv show system reboot counters 

reason-type           count 
-----------------     -------- 
user-initiated        7 
power-failure         3 
critical-error        5 
total                 15       

REST API

GET https://<ip>/nvue_v1/system/reboot/counters

Related commands

nv show system reboot history

Notes


nv action reboot system


nv action reboot system [mode {halt | cold | immediate}] [force]

Reboot switch system.

Syntax Description

flag

  • halt: Shuts down the system

  • cold: Allow a controlled shutdown by notifying all running processes that the system is going down

  • immediate: Reboot system immediately without notifying any running processes


force

Force the action without asking for user confirmation.

Default

N/A

History

25.02.2002 


25.02.5002

Updated reboot modes

Example

admin@nvos:~$ nv action reboot system
Configuration has been modified, but not saved.
Type [y] to reboot the system without saving configuration.
Type [N] to abort.

Do you want to continue? [Y/N] N
System reboot aborted by user
admin@nvos:~$ nv action reboot system mode halt
Type [y] to halt the system.
Type [N] to abort.
WARNING: This operation will shut down the system.
You will NOT be able to turn on the system remotely.

Do you want to continue? [y/N]

REST API

POST https://<ip>/nvue_v1/system

Related commands

nv action install platform firmware files

Notes

  • The prompt will be displayed only if there is unsaved configuration on the switch. Otherwise, the reboot will be performed as usual.

  • Using the halt flag will show the prompt unless force flag is passed.

  • Using the immediate flag will not trigger the firmware upgrade flow that part of normal reboot.

  • If the switch is in a fatal state, it will exit that state once it comes up.

  • `nv action reboot system` will still work as usual which is equivalent to `nv action reboot system mode cold`

nv show platform ps-redundancy


nv show platform ps-redundancy

Shows power supply redundancy policy

Syntax Description

N/A

Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform ps-redundancy

         operational     applied         
-------  --------------  --------------  
policy   grid-redundant  grid-redundant  
min-required  8             

REST API

GET https://<ip>/nvue_v1/platform/ps-redundancy

Related Commands

nv set platform ps-redundancy policy
nv show system health

Notes

Supported only in systems that do not require all the power supplies to be connected.

nv set platform ps-redundancy policy


nv set platform ps-redundancy policy {no-redundancy | ps-redundant | grid-redundant}

Sets system power redundancy policy. When the power redundancy policy requirements are not met a health  issue is raised

Syntax Description

no-redundancy

No power supply is reserved. The redundancy is not enabled.

ps-redundant

One power supply unit is redundant to the rest. The system can work with one less power supply unit.

grid-redundant

The power supplies are split into two logical power supply grids, each grid contains the minimum power supplies required by the system. The power supplies on the left side of the switch are one grid, and the power supplies on the right switch are the other. The system can work if all the power supplies of one grid fail.

Default

grid-redundant

History

25.02.2002 

Example

nv set platform ps-redundancy policy grid-redundant

REST API

PATCH https://<ip>/nvue_v1/ platform/ps-redundancy

Related Commands

nv show system health
nv show platform ps-redundancy

Notes

Supported only in systems that do not require all the power supplies to be connected.