NVIDIA NVOS User Manual for InfiniBand Switches

Environment Commands

nv show platform environment


nv show platform environment

Displays the types of data available under more specific platform environment commands.

Syntax Description

N/A


Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform environment
Name                             Type         State
-------------------------------  -----------  -----
ASIC                             temperature  ok
Ambient-Fan-Side-Temp            temperature  ok
CPU-Pack-Temp                    temperature  ok
FAN1                             led          off
FAN1/1                           fan          ok
FAN1/2                           fan          ok
FAN2                             led          off
FAN2/1                           fan          ok
FAN2/2                           fan          ok
FAN3                             led          off
FAN3/1                           fan          ok
FAN3/2                           fan          ok
FAN4                             led          off
FAN4/1                           fan          ok
FAN4/2                           fan          ok
FAN5                             led          off
FAN5/1                           fan          ok
FAN5/2                           fan          ok
FAN6                             led          off
FAN6/1                           fan          ok
FAN6/2                           fan          ok
HSC-VinDC-In                     voltage      ok
HSC-VinDC-Out                    voltage      ok
PDB-1-Conv-In-1                  voltage      ok
PDB-1-Conv-Out-1                 voltage      ok
PDB-2-Conv-In-1                  voltage      ok
PDB-2-Conv-Out-1                 voltage      ok
PDB-3-Conv-In-1                  voltage      ok
PDB-3-Conv-Out-1                 voltage      ok
PDB-4-Conv-In-1                  voltage      ok
PDB-4-Conv-Out-1                 voltage      ok
PMIC-1-12V-VDD-ASIC1-In-1        voltage      ok
PMIC-1-ASIC1-VDD-Out-1           voltage      ok
PMIC-2-12V-HVDD-DVDD-ASIC1-In-1  voltage      ok
PMIC-2-ASIC1-DVDD-PL0-Out-2      voltage      ok
PMIC-2-ASIC1-HVDD-PL0-Out-1      voltage      ok
PMIC-3-12V-HVDD-DVDD-ASIC1-In-1  voltage      ok
PMIC-3-ASIC1-DVDD-PL1-Out-2      voltage      ok
PMIC-3-ASIC1-HVDD-PL1-Out-1      voltage      ok
PMIC-4-12V-VDD-ASIC2-In-1        voltage      ok
PMIC-4-ASIC2-VDD-Out-1           voltage      ok
PMIC-5-12V-HVDD-DVDD-ASIC2-In-1  voltage      ok
PMIC-5-ASIC2-DVDD-PL0-Out-2      voltage      ok
PMIC-5-ASIC2-HVDD-PL0-Out-1      voltage      ok
PMIC-6-12V-HVDD-DVDD-ASIC2-In-1  voltage      ok
PMIC-6-ASIC2-DVDD-PL1-Out-2      voltage      ok
PMIC-6-ASIC2-HVDD-PL1-Out-1      voltage      ok
PMIC-7-12V-MAIN-In-1             voltage      ok
PMIC-7-CEX-VDD-Out-1             voltage      ok
PMIC-8-COMEX-VDD-MEM-In-1        voltage      ok
PMIC-8-COMEX-VDD-MEM-Out-1       voltage      ok
SODIMM-1-Temp                    temperature  ok
STATUS                           led          off
UID                              led          off

REST API

GET https://<ip>/nvue_v1/platform/environment

Related Commands

Environment Commands | id (25.02.8008)EnvironmentCommands nvshowplatformenvironmentfan
nv show platform environment led
nv show platform environment temperature

Notes


nv show platform environment fan


nv show platform environment fan <fan-id>

Displays the maximum, minimum, current speed and state for one or all fans in the system.

Syntax Description

fan-id

Name of the fan whose status to display.  If not entered, all fans are displayed.

Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform environment fan 
Name    Fan State  Current Speed (RPM)  Max Speed  Min Speed  Fan Direction
------  ---------  -------------------  ---------  ---------  -------------
FAN1/1  ok         23045                33000      6000       B2F
FAN1/2  ok         21634                33000      6000       B2F
FAN2/1  ok         23557                33000      6000       B2F
FAN2/2  ok         22085                33000      6000       B2F
FAN3/1  ok         22555                33000      6000       B2F
FAN3/2  ok         22085                33000      6000       B2F
FAN4/1  ok         22555                33000      6000       B2F
FAN4/2  ok         22085                33000      6000       B2F
FAN5/1  ok         22555                33000      6000       B2F
FAN5/2  ok         22085                33000      6000       B2F
FAN6/1  ok         22555                33000      6000       B2F
FAN6/2  ok         21634                33000      6000       B2F

admin@nvos:~$ nv show platform environment fan FAN1/1
               operational
-------------  -----------
state          ok
current-speed  22555
min-speed      6000
max-speed      33000
direction      B2F


REST API

GET https://<ip>/nvue_v1/platform/environment/fan
GET https://<ip>/nvue_v1/platform/environment/fan/{fan-id}

Related Commands

nv show platform environment

Notes


nv show platform environment led


nv show platform environment led <led-id>

Displays the status of one or all LEDs in the system.

Syntax Description

led-id

Name of the LED whose status to display.  If not entered, all LEDs are displayed.

Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform environment led
LED Name  LED Color
--------  ---------
FAN1      off
FAN2      off
FAN3      off
FAN4      off
FAN5      off
FAN6      off
STATUS    green
UID       blue
admin@nvos:~$ nv show platform environment led UID
       operational
-----  -----------
color  blue                 

REST API

GET https://<ip>/nvue_v1/platform/environment/led
GET https://<ip>/nvue_v1/platform/environment/led/{led-id}

Related Commands

nv show platform environment

Notes



nv show platform environment psu


nv show platform environment psu <psu-id>

Displays the capacity, current, power, voltage, and state for one or all PSUs in the system.

Syntax Description

psu-id

Name of the PSU whose status is to be displayed.  If psu-is is not specified, all PSUs are displayed.

Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform environment psu
Name  Capacity [W]  Current [A]  Power [W]  Voltage [V]  State 
----  ------------  -----------  ---------  -----------  ------
PSU1  N/A           N/A          N/A        N/A          absent
PSU2  2200.00       0.53         120.84     228.00       ok    
PSU3  2200.00       0.58         132.67     228.75       ok    
PSU4  N/A           N/A          N/A        N/A          absent
PSU5  N/A           N/A          N/A        N/A          absent
PSU6  2200.00       0.64         145.60     227.50       ok    
PSU7  2200.00       0.52         118.95     228.75       ok    
PSU8  N/A           N/A          N/A        N/A          absent
 
admin @nvos :~$ nv show platform environment psu PSU3
          operational
--------  -----------
state     ok         
capacity  2200.00    
current   0.60       
voltage   228.75     
power     137.25               

REST API

GET https://<ip>/nvue_v1/platform/environment/psu
GET https://<ip>/nvue_v1/platform/environment/psu/<psu-id>

Related Commands

nv show platform environment
nv show platform ps-redundancy

Notes

  • Depending on the system's power supply redundancy policy, not all PSUs must be present. Therefore, absent PSUs may not cause a system health issue.

  • All PSU sockets must be populated either by a PSU or by a dummy PSU.

  • PSUs without power will be in 'absent' state.

nv show platform environment temperature


nv show platform environment temperature <sensor-id>

Shows platform temperature and displays temperature information from different platform sensors.

Syntax Description

sensor-id

Name of the sensor whose data to display.  If not entered, all sensors are displayed.

Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform environment temperature 
Name             Cur Temp (°C)  Crit Temp  Max Temp  Min Temp  State
---------------  -------------  ---------  --------  --------  -----
ASIC1            44.00          120.00     105.00              ok   
ASIC2            44.00          120.00     105.00              ok   
ASIC3            45.00          120.00     105.00              ok   
ASIC4            45.00          120.00     105.00              ok   
CPU-Pack-Temp    30.75          100.00     95.00               ok   
Drive-Temp       25.85          94.85      89.85               ok   
HSC-VinDC-Temp   32.44          255.94     255.94              ok   
PDB-Conv-1-Temp  38.00          125.00                         ok   
PDB-Conv-2-Temp  36.00          125.00                         ok   
PMIC-1-Temp      39.00          125.00     105.00              ok   
PMIC-2-Temp      40.00          125.00     105.00              ok   
PMIC-3-Temp      43.00          125.00     105.00              ok   
PMIC-4-Temp      45.00          125.00     105.00              ok   
PMIC-5-Temp      45.00          125.00     105.00              ok   
PMIC-6-Temp      43.00          125.00     105.00              ok   
PMIC-7-Temp      42.00          125.00     105.00              ok   
PMIC-8-Temp      44.00          125.00     105.00              ok   
PMIC-9-Temp      43.00          125.00     105.00              ok   
PMIC-10-Temp     41.00          125.00     105.00              ok   
PMIC-11-Temp     43.00          125.00     105.00              ok   
PMIC-12-Temp     43.00          125.00     105.00              ok   
PMIC-13-Temp     39.00          125.00     105.00              ok   
PMIC-14-Temp     36.00          125.00     105.00              ok   
PMIC-15-Temp     36.00          125.00     105.00              ok   
PMIC-16-Temp     36.00          125.00     105.00              ok   
PMIC-17-Temp     30.00          120.00                         ok   
PMIC-18-Temp     30.00          115.00     105.00              ok   
SODIMM-1-Temp    29.00          95.00      85.00               ok   
SODIMM-2-Temp    29.38          95.00      85.00               ok   
admin@rosalind-eb2-2102:~$ 
admin@nvos:~$ nv show platform environment temperature CPU-Pack-Temp 
         operational
-------  -----------
state    ok         
current  30.50      
max      95.00      
crit     100.00     
           

REST API

GET https://<ip>/nvue_v1/platform/environment/temperature
GET https://<ip>/nvue_v1/platform/environment/temperature/<sensor-id>

Related Commands

nv show platform environment

Notes

Note the quotes needed for sensor ID containing a space.

nv show platform environment voltage


nv show platform environment voltage 

Displays a table with all voltage sensors located on the chassis.

Syntax Description

N/A


Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform environment voltage 
Name                                Actual (V)  Maximum (V)  Minimum (V)  State
----------------------------------  ----------  -----------  -----------  -----
HSC-VinDC-In                        54.35       88.72        0.03         ok   
HSC-VinDC-Out                       54.39                    0.00         ok   
PDB-1-Conv-In-1                     54.20       61.50        38.00        ok   
PDB-1-Conv-Out-1                    12.00       14.10        10.00        ok   
PDB-2-Conv-In-1                     53.70       61.50        38.00        ok   
PDB-2-Conv-Out-1                    11.99       14.10        10.00        ok   
PMIC-1-ASIC1-VDD-Out-1              0.70        0.98         0.35         ok   
PMIC-1-PVIN1-VDD-ASIC1-In-1         12.06       16.00        8.00         ok   
PMIC-2-ASIC1-AVDD-PL0-Out-1         1.05        1.36         0.55         ok   
PMIC-2-ASIC1-DVDD-PL0-Out-2         0.74        0.90         0.25         ok   
PMIC-2-PVIN1-AVDD-DVDD-ASIC1-In-1   12.00       16.00        8.00         ok   
PMIC-3-ASIC1-AVDD-PL1-Out-1         1.05        1.36         0.55         ok   
PMIC-3-ASIC1-DVDD-PL1-Out-2         0.74        0.90         0.25         ok   
PMIC-3-PVIN1-AVDD-DVDD-ASIC1-In-1   12.06       16.00        8.00         ok   
PMIC-4-ASIC1-AVCC-PL0-PL1-Out-1     1.80        2.00         1.30         ok   
PMIC-4-ASIC1-HVDD-PL0-PL1-Out-2     1.20        1.50         0.80         ok   
PMIC-4-PVIN1-AVCC-HVDD-ASIC1-In-1   12.00       16.00        8.00         ok   
PMIC-5-ASIC2-VDD-Out-1              0.70        0.98         0.35         ok   
PMIC-5-PVIN1-VDD-ASIC2-In-1         12.06       16.00        8.00         ok   
PMIC-6-ASIC2-AVDD-PL0-Out-1         1.05        1.36         0.55         ok   
PMIC-6-ASIC2-DVDD-PL0-Out-2         0.74        0.90         0.25         ok   
PMIC-6-PVIN1-AVDD-DVDD-ASIC2-In-1   12.06       16.00        8.00         ok   
PMIC-7-ASIC2-AVDD-PL1-Out-1         1.05        1.36         0.55         ok   
PMIC-7-ASIC2-DVDD-PL1-Out-2         0.74        0.90         0.25         ok   
PMIC-7-PVIN1-AVDD-DVDD-ASIC2-In-1   12.06       16.00        8.00         ok   
PMIC-8-ASIC2-AVCC-PL0-PL1-Out-1     1.80        2.00         1.30         ok   
PMIC-8-ASIC2-HVDD-PL0-PL1-Out-2     1.20        1.50         0.80         ok   
PMIC-8-PVIN1-AVCC-HVDD-ASIC2-In-1   12.06       16.00        8.00         ok   
PMIC-9-ASIC3-VDD-Out-1              0.71        0.98         0.35         ok   
PMIC-9-PVIN1-VDD-ASIC3-In-1         12.06       16.00        8.00         ok   
PMIC-10-ASIC3-AVDD-PL0-Out-1        1.05        1.36         0.55         ok   
PMIC-10-ASIC3-DVDD-PL0-Out-2        0.74        0.90         0.25         ok   
PMIC-10-PVIN1-AVDD-DVDD-ASIC3-In-1  12.12       16.00        8.00         ok   
PMIC-11-ASIC3-AVDD-PL1-Out-1        1.05        1.36         0.55         ok   
PMIC-11-ASIC3-DVDD-PL1-Out-2        0.74        0.90         0.25         ok   
PMIC-11-PVIN1-AVDD-DVDD-ASIC3-In-1  12.09       16.00        8.00         ok   
PMIC-12-ASIC3-AVCC-PL0-PL1-Out-1    1.80        2.00         1.30         ok   
PMIC-12-ASIC3-HVDD-PL0-PL1-Out-2    1.20        1.50         0.80         ok   
PMIC-12-PVIN1-AVCC-HVDD-ASIC3-In-1  12.06       16.00        8.00         ok   
PMIC-13-ASIC4-VDD-Out-1             0.70        0.98         0.35         ok   
PMIC-13-PVIN1-VDD-ASIC4-In-1        12.06       16.00        8.00         ok   
PMIC-14-ASIC4-AVDD-PL0-Out-1        1.05        1.36         0.55         ok   
PMIC-14-ASIC4-DVDD-PL0-Out-2        0.74        0.90         0.25         ok   
PMIC-14-PVIN1-AVDD-DVDD-ASIC4-In-1  12.06       16.00        8.00         ok   
PMIC-15-ASIC4-AVDD-PL1-Out-1        1.05        1.36         0.55         ok   
PMIC-15-ASIC4-DVDD-PL1-Out-2        0.74        0.90         0.25         ok   
PMIC-15-PVIN1-AVDD-DVDD-ASIC4-In-1  12.06       16.00        8.00         ok   
PMIC-16-ASIC4-AVCC-PL0-PL1-Out-1    1.80        2.00         1.30         ok   
PMIC-16-ASIC4-HVDD-PL0-PL1-Out-2    1.20        1.50         0.80         ok   
PMIC-16-PVIN1-AVCC-HVDD-ASIC4-In-1  12.06       16.00        8.00         ok   
PMIC-17-12V-MAIN-In-1               12.06                                 ok   
PMIC-17-CPU-Out-1                   1.03        1.23         0.61         ok   
PMIC-17-SOC-Out-2                   0.96        1.16         0.53         ok   
PMIC-18-COMEX-VDD-MEM-In-1          12.00       16.00                     ok   
PMIC-18-COMEX-VDD-MEM-Out-1         1.20        1.42         0.90         ok   

REST API

 GET https://<ip>/nvue_v1/platform/environment/voltage

Related Commands

nv show platform environment voltage

Notes


nv show platform environment voltage sensor


 nv show platform environment voltage <sensor-id>

 Display voltage of a specific sensor.

Syntax Description

N/A

Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv show platform environment voltage PMIC-1-12V-VDD-ASIC1-In-1
        operational
------  -----------
state   ok
actual  13.44
max     16.00
min     0.03

REST API

 GET https://<ip>/nvue_v1/platform/environment/voltage/{sensor-id}

Related Commands

 nv show platform environment voltage

Notes

 This command is supported only on QM9700 platforms

nv action turn-on/turn-off platform environment led UID


nv action turn-on platform environment led UID
nv action turn-off platform environment led UID

Turns on/off the LED UID.

Syntax Description

N/A


Default

N/A

History

25.02.2002 

Example

admin@nvos:~$ nv action turn-on platform environment led UID

REST API

POST https://<ip>/nvue_v1/platform/environment/led/UID

Related Commands


Notes


Last updated: