To upgrade NVIDIA Onyx on an MLAG-STP setup from 3.6.610x to this version, there are two possible procedures:
Procedure 1
-
Make sure there are no loops in the fabric.
-
Disable STP. Run:
switch (config) # no spanning-tree -
Perform the upgrade according to steps 1-10 in "Upgrading Operating System Software".
-
Enable STP – this step may lead to traffic loss while the STP state is converging. Run:
switch (config) # spanning-tree
Procedure 2:
-
Shutdown all ports except for the MLAG IPL Port-Channel on the MLAG stanby switch, make sure not to shutdown the MLAG IPL Port-Channel ports.
-
Save configuration. Run:
switch (config) # configuration write -
Upgrade MLAG stanby switch according to steps 1–10 in "Upgrading Operating System Software".
-
Once the MLAG stanby switch is back online with the new version, use "show mlag" and "show mlag-vip" commands and verify both processes are up. Next enable all ports on the MLAG stanby switch, and verify all ports are back online.
-
Upgrade MLAG master according to steps 1–3 above, and use the below command to reboot the master:
switch (config) # reload force immediate -
Once the MLAG master is back online with the new version, use "show mlag" and "show mlag-vip" command and verify all is up. Next enable all ports on the MLAG master, and verify all ports are back online.
Last updated: