Ref # |
Issue |
||
|---|---|---|---|
|
Rev 6.20.0 / 6.20.1 |
|||
|
4261896 |
Description: XDR optical cable transceivers (Wolvarine) information is not exposed in UFM (for both REST API and Web UI) |
||
|
Keywords: Cable, Transceiver, Info, Wolvarine |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: 6.20.0 |
|||
|
4289083 |
Description: ibdiagnet, a diagnostic tool for InfiniBand networks, fails to discover unmanaged switches when a specific VS key is enabled, resulting in incomplete network discovery. |
||
|
Keywords: ibdiagnet, Unmanaged Switches, VS key |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: 6.20.0 |
|||
|
4221551 |
Description: Removed the " |
||
|
Keywords: Plugin, Upgrade, |
|||
|
Workaround: For upgrading UFM plugins, please refer to the instruction provided in UFM Plugin Upgrade Procedure. |
|||
|
Discovered in Release: 6.20.0 |
|||
|
Rev 6.19.6 |
|||
|
4224081 |
Description: Burning of XDR cables using XDR switch is not supported. |
||
|
Keywords: XDR, Cables, Switch |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: 6.19.6 |
|||
|
3397981 |
Description: Showing extended cable information for aggregated XDR switch port is not supported by UFM. |
||
|
Keywords: XDR, Cable Information, Switch |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: 6.19.6 |
|||
|
Rev 6.19.0 |
|||
|
4119214 |
Description: In case of pulling telemetry data from the UFM server (High or low-frequency instances), the loopback/local host IP should be used instead of the hostname or host IP. Example of High-Frequency (Primary) Telemetry Instance:
Example of Low-Frequency (Secondary) Telemetry Instance:
|
||
|
Keywords: Localloop IP, Telemetry, Local Host |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: 6.19.0 |
|||
|
4151847 |
Description: Primary Telemetry is not updated properly |
||
|
Keywords: Primary Telemetry |
|||
|
Workaround: Comment out or remove the line that defines If UFM is already running, restart the telemetry service for the change to take effect by running |
|||
|
Discovered in Release: 6.19.0 |
|||
|
4157855 |
Description: The High-Frequency (Primary) Telemetry instance is missing the necessary environment variable in UTM (non-legacy) mode, which causes an incorrect sample rate.
|
||
|
Keywords: Telemetry |
|||
|
Workaround:
|
|||
|
Discovered in Release: 6.19.0 |
|||
|
4172677 |
Description: UFM Telemetry server experiencing slowdowns in data collection and response to requests |
||
|
Keywords: Telemetry, Slowdown, Data Collection |
|||
|
Workaround: Implement the following configuration update on both the primary and secondary telemetry:
Then, restart UFM or UFM Telemetry. |
|||
|
Discovered in Release: 6.19.0 |
|||
|
4161921 |
Description: VL15 counters are returned NA due to invalid parsing of the response. |
||
|
Keywords: L15 counters, Management Traffic, ibdiagnet |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: 6.19.0 |
|||
|
Rev 6.18.0 |
|||
|
3991199 |
Description: Dynamic Telemetry instances are not recovered during the backup/restore procedure |
||
|
Keywords: Dynamic Telemetry, Backup, Restore |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: 6.17.5 |
|||
|
Rev 6.17.0 |
|||
|
3859362 |
Description: UFM TFS endpoint dashboard report Switch port TX/RX rate reach Tbps |
||
|
Keywords: TFS, Switch Port, TX/RX |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: v6.15.1 |
|||
|
|
Description: Malfunctioning of the rest API when deleting port associated to a pkey |
||
|
Keywords: CloudX, API, Bare-Metal |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: v6.15.2 |
|||
|
3862847 |
Description: UFM reports wrong cable length for NDR optical cables connected to Quantum-2 NDR switch |
||
|
Keywords: NDR, Optical Cables, Quantum-2, Switch |
|||
|
Workaround: N/A |
|||
|
Discovered in Release: v6.17.0 |
|||
Last updated: