This reference lists the threshold-based events that UFM supports, each including a set of attributes listed below. You can view these messages through Events & Alarms. For details about configuring notifications for these events, refer to Configuring Event Management.
-
Event ID: Unique event identifier
-
Event Name: Short description of the event
-
To log: A flag which defines whether the event will be sent to UFM events log or not (1 or 0, respectively).
-
Alarm: A flag which defines whether UFM alarm is generated when the specified event is triggered by UFM (1 means an alarm is generated). Alarms are used to allow a notification with significant indication.
-
Default Severity: Indicates the alarm severity (Info, Warning, Minor, Critical)
-
Default Threshold: Event dependent threshold (for example, event occurrence, counter threshold or temperature threshold).
-
Default TTL: TTL (Alarm Time to Live) sets the time during which the alarm on the event is visible on UFM Web UI. TTL is defined in seconds. CAUTION: Setting the TTL to 0 makes the alarm permanent, meaning that the alarm does not disappear from the Web UI until cleared manually.
-
Related Object: The object (context) to which the UFM event is related to (port, switch, gateway, grid, etc).
-
Category: Indicates the category to which the event is related to.
-
Source: Indicates the origin source of the specified event (SM, Telemetry, Licensing, UFM)
For information about defining event policy, see Configuring Event Management.
|
Alarm ID |
Alarm Name |
To Log |
Alarm |
Default Severity |
Default Threshold |
Default TTL |
Related Object |
Category |
Source |
|---|---|---|---|---|---|---|---|---|---|
|
64 |
GID Address In Service |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
|
65 |
GID Address Out of Service |
1 |
1 |
Warning |
1 |
0 |
Port |
Fabric Notification |
SM |
|
66 |
New MCast Group Created |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
|
67 |
MCast Group Deleted |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
|
110 |
Symbol Error |
1 |
1 |
Warning |
200 |
0 |
Port |
Hardware |
Telemetry |
|
111 |
Link Error Recovery |
1 |
1 |
Minor |
1 |
0 |
Port |
Hardware |
Telemetry |
|
112 |
Link Downed |
1 |
1 |
Warning |
0 |
0 |
Port |
Hardware |
Telemetry |
|
113 |
Port Receive Errors |
1 |
1 |
Warning |
5 |
0 |
Port |
Hardware |
Telemetry |
|
114 |
Port Receive Remote Physical Errors |
1 |
1 |
Minor |
5 |
0 |
Port |
Hardware |
Telemetry |
|
115 |
Port Receive Switch Relay Errors |
1 |
1 |
Minor |
50 |
0 |
Port |
Fabric Configuration |
Telemetry |
|
116 |
Port Xmit Discards |
1 |
1 |
Minor |
200 |
0 |
Port |
Communication Error |
Telemetry |
|
117 |
Port Xmit Constraint Errors |
1 |
1 |
Minor |
1 |
0 |
Port |
Communication Error |
Telemetry |
|
118 |
Port Receive Constraint Errors |
1 |
1 |
Minor |
1 |
0 |
Port |
Communication Error |
Telemetry |
|
119 |
Local Link Integrity Errors |
1 |
1 |
Minor |
5 |
0 |
Port |
Hardware |
Telemetry |
|
120 |
Excessive Buffer Overrun Errors |
1 |
1 |
Warning |
1 |
0 |
Port |
Communication Error |
Telemetry |
|
121 |
VL15 Dropped |
1 |
1 |
Info |
500 |
0 |
Port |
Communication Error |
Telemetry |
|
122 |
Congested Bandwidth (%) Threshold Reached |
1 |
1 |
Minor |
10 |
0 |
Port |
Communication Error |
Telemetry |
|
123 |
Port Bandwidth (%) Threshold Reached |
1 |
1 |
Minor |
95 |
0 |
Port |
Communication Error |
Telemetry |
|
130 |
Non-optimal link width |
1 |
1 |
Minor |
1 |
0 |
Port |
Hardware |
SM |
|
134 |
T4 Port Congested Bandwidth |
1 |
1 |
Warning |
10 |
0 |
Port |
Communication Error |
Telemetry |
|
141 |
Flow Control Update Watchdog Timer Expired |
1 |
1 |
Warning |
1 |
0 |
Port |
Hardware |
SM |
|
144 |
Capability Mask Modified |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
|
145 |
System Image GUID changed |
1 |
1 |
Info |
1 |
0 |
Port |
Communication Error |
SM |
|
156 |
Link Speed Enforcement Disabled |
1 |
0 |
Critical |
0 |
0 |
Site |
Fabric Notification |
SM |
|
250 |
Running in Limited Mode |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
|
251 |
Switching to Limited Mode |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
|
252 |
License Expired |
1 |
1 |
Warning |
1 |
0 |
Grid |
Maintenance |
Licensing |
|
253 |
Duplicated licenses |
1 |
0 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
|
254 |
License Limit Exceeded |
1 |
0 |
Critical |
1 |
0 |
Grid |
Maintenance |
Licensing |
|
255 |
License is About to Expire |
1 |
0 |
Warning |
1 |
0 |
Grid |
Maintenance |
Licensing |
|
256 |
Bad M_Key |
1 |
1 |
Critical |
1 |
0 |
Port |
Security |
SM |
|
257 |
Bad P_Key |
1 |
1 |
Critical |
1 |
0 |
Port |
Security |
SM |
|
258 |
Bad Q_Key |
1 |
1 |
Critical |
1 |
0 |
Port |
Security |
SM |
|
259 |
Bad P_Key Switch External Port |
1 |
0 |
Minor |
1 |
0 |
Port |
Security |
SM |
|
271 |
ISBL LAG Port Up |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
|
272 |
ISBL LAG Port Down |
0 |
0 |
Critical |
1 |
0 |
Port |
Fabric Notification |
SM |
|
273 |
LAG Port Up |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
|
274 |
LAG Port Down |
0 |
0 |
Warning |
1 |
0 |
Port |
Fabric Notification |
SM |
|
275 |
Port Up |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
UFM |
|
276 |
Port Down |
0 |
0 |
Warning |
1 |
0 |
Port |
Fabric Notification |
UFM |
|
277 |
Port of LAG Up |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
UFM |
|
278 |
Port of LAG Down |
0 |
0 |
Warning |
1 |
0 |
Port |
Fabric Notification |
UFM |
|
279 |
Port of ISBL Up |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
UFM |
|
280 |
Port of ISBL Down |
0 |
0 |
Warning |
1 |
0 |
Port |
Fabric Notification |
UFM |
|
328 |
Link is Up |
1 |
0 |
Info |
1 |
10 |
Site |
Fabric Topology |
UFM |
|
329 |
Link is Down |
1 |
0 |
Warning |
1 |
10 |
Site |
Fabric Topology |
UFM |
|
331 |
Node is Down |
1 |
0 |
Warning |
1 |
0 |
Site |
Fabric Topology |
UFM |
|
332 |
Node is Up |
1 |
0 |
Info |
1 |
0 |
Site |
Fabric Topology |
UFM |
|
336 |
Port Action Succeeded |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
|
337 |
Port Action Failed |
0 |
0 |
Critical |
1 |
0 |
Port |
Maintenance |
UFM |
|
338 |
Device Action Succeeded |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
|
339 |
Device Action Failed |
0 |
0 |
Critical |
1 |
0 |
Port |
Maintenance |
UFM |
|
344 |
Partial Switch ASIC Failure |
1 |
1 |
Critical |
1 |
0 |
Switch |
Maintenance |
UFM |
|
352 |
Network Added |
0 |
0 |
Info |
1 |
0 |
Network |
Logical Model |
UFM |
|
353 |
Network Removed |
0 |
0 |
Info |
1 |
0 |
Network |
Logical Model |
UFM |
|
380 |
Switch Upgrade Error |
1 |
1 |
Critical |
1 |
0 |
Switch |
Maintenance |
UFM |
|
381 |
Switch Upgrade Error |
1 |
1 |
Critical |
1 |
0 |
Switch |
Maintenance |
UFM |
|
382 |
Module status NOT PRESENT |
1 |
1 |
Warning |
1 |
0 |
Switch |
Module Status |
UFM |
|
383 |
Host Upgrade Failed |
1 |
1 |
Warning |
1 |
0 |
Computer |
Maintenance |
UFM |
|
384 |
Switch Module Powered Off |
1 |
1 |
Info |
1 |
0 |
Switch |
Module Status |
UFM |
|
385 |
Switch FW Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Switch |
Maintenance |
UFM |
|
386 |
Switch SW Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Switch |
Maintenance |
UFM |
|
387 |
Switch Upgrade Finished |
1 |
0 |
Info |
1 |
0 |
Switch |
Maintenance |
UFM |
|
388 |
Host FW Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Computer |
Maintenance |
UFM |
|
389 |
Host OFED Upgrade Started |
1 |
0 |
Info |
1 |
0 |
Computer |
Maintenance |
Switch |
|
391 |
Switch Module Removed |
1 |
0 |
Info |
1 |
0 |
Switch |
Fabric Notification |
Switch |
|
392 |
Module Temperature Threshold Reached (Managed IB switches only) |
1 |
1 |
Critical |
80 |
0 |
Module |
Hardware |
Switch |
|
393 |
Switch Module Added |
1 |
0 |
Info |
1 |
0 |
Switch |
Fabric Notification |
Switch |
|
394 |
Module status FAULT |
1 |
1 |
Critical |
1 |
0 |
Switch |
Module Status |
Switch |
|
395 |
Device Action Started |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
|
396 |
Site Action Started |
1 |
0 |
Info |
1 |
0 |
Port |
Maintenance |
UFM |
|
397 |
Site Action Failed |
0 |
0 |
Minor |
1 |
0 |
Port |
Maintenance |
UFM |
|
398 |
Switch Chip Added |
1 |
0 |
Info |
1 |
0 |
Switch |
Fabric Notification |
Switch |
|
399 |
Switch Chip Removed |
1 |
0 |
Critical |
1 |
0 |
Switch |
Fabric Notification |
Switch |
|
400 |
Switch Module Replaced |
1 |
0 |
Info |
1 |
0 |
Switch |
Fabric Notification |
Switch |
|
403 |
Device Pending Reboot |
1 |
1 |
Warning |
0 |
0 |
Device |
Maintenance |
UFM |
|
404 |
System Information is missing |
1 |
1 |
Warning |
1 |
0 |
Switch |
Communication Error |
UFM |
|
405 |
Switch Identity Validation Failed |
1 |
1 |
Warning |
1 |
0 |
Switch |
Communication Error |
UFM |
|
406 |
Switch System Information is missing |
1 |
1 |
Warning |
1 |
0 |
Switch |
Communication Error |
UFM |
|
407 |
COMEX Ambient Temperature Threshold Reached |
1 |
1 |
Minor |
60 |
0 |
Switch |
Hardware |
Switch |
|
408 |
Switch is Unresponsive |
1 |
1 |
Critical |
1 |
0 |
Switch |
Communication Error |
UFM |
|
502 |
Device Upgrade Finished |
1 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
|
506 |
Device Upgrade Finished |
1 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
|
508 |
Core Dump Created |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
SM |
|
510 |
SM Failover |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
SM |
|
511 |
SM State Change |
1 |
1 |
Info |
1 |
0 |
Grid |
Fabric Notification |
SM |
|
512 |
SM UP |
1 |
1 |
Info |
1 |
0 |
Grid |
Fabric Notification |
SM |
|
513 |
SM System Log Message |
1 |
1 |
Minor |
1 |
0 |
Grid |
Fabric Notification |
SM |
|
514 |
SM LID Change |
1 |
1 |
Warning |
1 |
0 |
Grid |
Fabric Notification |
SM |
|
515 |
Fabric Health Report Info |
1 |
1 |
Info |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
516 |
Fabric Health Report Warning |
1 |
1 |
Warning |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
517 |
Fabric Health Report Error |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
518 |
UFM-related process is down |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
519 |
Logs purge failure |
1 |
1 |
Minor |
1 |
0 |
Grid |
Maintenance |
UFM |
|
520 |
Restart of UFM-related process succeeded |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
521 |
UFM is being stopped |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
522 |
UFM is being restarted |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
523 |
UFM failover is being attempted |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
524 |
UFM cannot connect to DB |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
525 |
Disk utilization threshold reached |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
526 |
Memory utilization threshold reached |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
527 |
CPU utilization threshold reached |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
528 |
Fabric interface is down |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
529 |
UFM standby server problem |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
530 |
SM is down |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
531 |
DRBD Bad Condition |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
532 |
Remote UFM-SM Sync |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
533 |
Remote UFM-SM problem |
1 |
1 |
Critical |
1 |
0 |
Site |
Maintenance |
UFM |
|
536 |
UFM Health Watchdog Info |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
537 |
UFM Health Watchdog Critical |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
538 |
Time Diff Between HA Servers |
1 |
1 |
Warning |
1 |
0 |
Grid |
Maintenance |
UFM |
|
539 |
DRBD TCP Connection Performance |
1 |
1 |
Warning |
1 |
0 |
Grid |
Maintenance |
UFM |
|
540 |
Daily Report Completed successfully |
1 |
0 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
541 |
Daily Report Completed with Error |
1 |
0 |
Minor |
1 |
0 |
Grid |
Maintenance |
UFM |
|
542 |
Daily Report Failed |
1 |
0 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
543 |
Daily Report Mail Sent successfully |
1 |
0 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
544 |
Daily Report Mail Sent Failed |
1 |
0 |
Minor |
1 |
0 |
Grid |
Maintenance |
UFM |
|
545 |
SM is not responding |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
546 |
Management interface is down |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
547 |
UFM stopped polling SM for updates |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
548 |
Failed to run generic script test |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
551 |
General External Event Notification |
1 |
0 |
Info |
0 |
0 |
Grid |
Maintenance |
UFM |
|
552 |
General External Event Notice |
1 |
0 |
Minor |
0 |
0 |
Grid |
Maintenance |
UFM |
|
553 |
General External Event Alert |
1 |
0 |
Warning |
0 |
0 |
Grid |
Maintenance |
UFM |
|
554 |
General External Event Error |
1 |
0 |
Critical |
0 |
0 |
Grid |
Maintenance |
UFM |
|
560 |
User Connected |
1 |
0 |
Info |
1 |
0 |
Grid |
Security |
UFM |
|
561 |
User Disconnected |
1 |
0 |
Info |
1 |
0 |
Grid |
Security |
UFM |
|
602 |
UFM Server Failover |
1 |
1 |
Critical |
1 |
0 |
Site |
Fabric Notification |
UFM |
|
603 |
Events Suppression |
1 |
0 |
Critical |
0 |
0 |
Site |
Maintenance |
UFM |
|
604 |
Report Succeeded |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
605 |
Report Failed |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
606 |
Correction Attempts Paused |
1 |
0 |
Warning |
1 |
0 |
Site |
Fabric Notification |
UFM |
|
610 |
Monitoring History Enabled |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
611 |
Monitoring History Disabled |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
612 |
Monitoring History Bad Connection |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
613 |
Monitoring History Connection Established |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
614 |
Monitoring History Inconsistent Version |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
615 |
Monitoring History Failed save metadata |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
616 |
Monitoring History Failed update metadata |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
617 |
Monitoring History Failed save data |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
618 |
Monitoring History Failed get metadata |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
619 |
Monitoring History Failed get data |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
620 |
Monitoring History Failed remove file |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
621 |
Monitoring History version not matches UFM version |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
622 |
Monitoring History Purge DB Occurred |
1 |
1 |
Warning |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
623 |
Monitoring History Migration is not completed |
1 |
1 |
Warning |
1 |
0 |
Grid |
Maintenance |
UFM |
|
624 |
Monitoring History partition utilization threshold reached |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
625 |
Monitoring History local report files are about to be cleaned |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
626 |
Monitoring History oldest DB table is about to be removed |
1 |
1 |
Info |
1 |
0 |
Grid |
Maintenance |
UFM |
|
627 |
Monitoring History partition is not mounted |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
701 |
Non-optimal Link Speed |
1 |
1 |
Minor |
1 |
0 |
Port |
Hardware |
UFM |
|
702 |
Unhealthy IB Port |
1 |
1 |
Warning |
1 |
0 |
Port |
Hardware |
UFM |
|
703 |
Fabric Collector Connected |
1 |
0 |
Info |
1 |
0 |
Grid |
Maintenance |
SM |
|
704 |
Fabric Collector Disconnected |
1 |
1 |
Critical |
1 |
0 |
Grid |
Maintenance |
UFM |
|
750 |
High data retransmission count on port |
1 |
1 |
Warning |
500 |
0 |
Port |
Hardware |
SM |
|
901 |
Fabric Configuration Started |
1 |
1 |
Info |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
902 |
Fabric Configuration Completed |
1 |
1 |
Info |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
903 |
Fabric Configuration Failed |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
904 |
Device Configuration Failure |
1 |
1 |
Critical |
1 |
0 |
Device |
Fabric Notification |
UFM |
|
905 |
Device Configuration Timeout |
1 |
1 |
Critical |
1 |
0 |
Device |
Fabric Notification |
UFM |
|
906 |
Provisioning Validation Failure |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
907 |
Switch is Down |
1 |
1 |
Critical |
1 |
120 |
Site |
Fabric Topology |
UFM |
|
908 |
Switch is Up |
1 |
1 |
Info |
1 |
120 |
Site |
Fabric Topology |
UFM |
|
909 |
Director Switch is Down |
1 |
1 |
Critical |
1 |
300 |
Site |
Fabric Topology |
UFM |
|
910 |
Director Switch is Up |
1 |
1 |
Info |
1 |
300 |
Site |
Fabric Topology |
UFM |
|
911 |
Module Temperature Low Threshold Reached (Unmanaged IB switches only) |
1 |
1 |
Warning |
0 |
0 |
Module |
Hardware |
Telemetry |
|
912 |
Module Temperature High Threshold Reached (Unmanaged IB switches only) |
1 |
1 |
Critical |
0 |
0 |
Module |
Hardware |
Telemetry |
|
913 |
Module High Voltage |
1 |
1 |
Warning |
15 |
0 |
Switch |
Module Status |
Telemetry |
|
914 |
Module High Current |
1 |
1 |
Warning |
10 |
0 |
Switch |
Module Status |
Telemetry |
|
915 |
Critical BER reported |
1 |
1 |
Critical |
10 |
0 |
PORT |
Hardware |
Telemetry |
|
916 |
High BER reported |
1 |
1 |
Warning |
10 |
0 |
PORT |
Hardware |
Telemetry |
|
917 |
Critical Symbol BER reported |
1 |
1 |
Critical |
10 |
0 |
PORT |
Hardware |
Telemetry |
|
918 |
High Symbol BER reported |
1 |
1 |
Warning |
10 |
0 |
PORT |
Hardware |
Telemetry |
|
919 |
Cable Temperature High |
1 |
1 |
Critical |
0 |
0 |
Port |
Hardware |
UFM |
|
920 |
Cable Temperature Low |
1 |
1 |
Critical |
0 |
0 |
Port |
Hardware |
UFM |
|
921 |
Fan Speed Below Minimum Threshold |
1 |
1 |
Warning |
0 |
0 |
Module |
Hardware |
UFM |
|
922 |
Fan Speed Above Maximum Threshold |
1 |
1 |
Critical |
0 |
0 |
Module |
Hardware |
UFM |
|
1257 |
VPort P_key Violation |
1 |
1 |
Critical |
0 |
0 |
Port |
Security |
UFM |
|
1258 |
VPort Q_Key Violation |
1 |
1 |
Critical |
0 |
0 |
Port |
Security |
UFM |
|
1300 |
SA Key violation |
1 |
1 |
Critical |
5 |
0 |
Port |
Security |
SM |
|
1301 |
SGID Spoofed |
1 |
1 |
Critical |
5 |
0 |
Port |
Security |
SM |
|
1302 |
SA High Rate detected |
1 |
1 |
Warning |
5 |
0 |
Port |
Security |
SM |
|
1303 |
Multicast subscriptions over limit |
1 |
1 |
Critical |
5 |
0 |
Port |
Security |
SM |
|
1304 |
Service Record subscriptions over limit |
1 |
1 |
Critical |
5 |
0 |
Port |
Security |
SM |
|
1305 |
Event subscriptions over limit |
1 |
1 |
Warning |
5 |
0 |
Port |
Security |
SM |
|
1306 |
Unallowed SM was detected in the fabric |
1 |
1 |
Critical |
0 |
0 |
Port |
Fabric Notification |
SM |
|
1307 |
SMInfo SET request was received from unallowed SM |
1 |
1 |
Critical |
0 |
0 |
Port |
Fabric Notification |
SM |
|
1309 |
SM was detected with non-matching SMKey |
1 |
1 |
Critical |
0 |
0 |
Port |
Fabric Notification |
SM |
|
1310 |
Duplicated node GUID was detected |
1 |
1 |
Critical |
1 |
0 |
Device |
Fabric Notification |
SM |
|
1311 |
Duplicated port GUID was detected |
1 |
1 |
Critical |
1 |
0 |
Port |
Fabric Notification |
SM |
|
1312 |
Switch was Rebooted |
1 |
1 |
Info |
1 |
0 |
Device |
Fabric Notification |
UFM |
|
1315 |
Topo Config File Error |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
UFM |
|
1316 |
Topo Config Subnet Mismatch |
1 |
1 |
Critical |
1 |
0 |
Grid |
Fabric Notification |
Topodiff |
|
1321 |
Link Flaps |
1 |
0 |
Warning |
0 |
10 |
Site |
Fabric Topology |
SM |
|
1322 |
IB Mad Keys Periodic Update |
1 |
0 |
Info |
0 |
0 |
Site |
Fabric Notification |
SM |
|
1400 |
High Ambient Temperature |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1401 |
High Fluid Temperature |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1402 |
Low Fluid Level |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1403 |
Low Supply Pressure |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1404 |
High Supply Pressure |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1405 |
Low Return Pressure |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1406 |
High Return Pressure |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1407 |
High Differential Pressure |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1408 |
Low Differential Pressure |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1409 |
System Fail Safe |
1 |
1 |
Warning |
0 |
0 |
Switch |
Hardware |
Switch |
|
1410 |
Fault Critical |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1411 |
Fault Pump1 |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1412 |
Fault Pump2 |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1413 |
Fault Fluid Level Critical |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1414 |
Fault Fluid Over Temperature |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1415 |
Fault Primary DC |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1416 |
Fault Redundant DC |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1417 |
Fault Fluid Leak |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1418 |
Fault Sensor Failure |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1419 |
Cooling Device Monitoring Error |
1 |
0 |
Critical |
0 |
0 |
Grid |
Hardware |
Switch |
|
1420 |
Cooling Device Communication Error |
1 |
1 |
Critical |
0 |
0 |
Switch |
Hardware |
Switch |
|
1500 |
New Cable Detected |
1 |
0 |
Info |
1 |
0 |
Site |
Security |
UFM |
|
1502 |
Cable detected in a new location |
1 |
0 |
Warning |
1 |
0 |
Site |
Security |
UFM |
|
1503 |
Duplicate Cable Detected |
1 |
0 |
Critical |
1 |
0 |
Site |
Security |
UFM |
|
1504 |
SHARP Allocation Succeeded |
0 |
0 |
Info |
1 |
0 |
Grid |
SHARP |
SHARP |
|
1505 |
SHARP Allocation Failed |
0 |
0 |
Warning |
1 |
0 |
Grid |
SHARP |
SHARP |
|
1506 |
SHARP Deallocation Succeeded |
0 |
0 |
Info |
1 |
0 |
Grid |
SHARP |
SHARP |
|
1507 |
SHARP Deallocation Failed |
0 |
0 |
Warning |
1 |
0 |
Grid |
SHARP |
SHARP |
|
1508 |
Device Collect System Dump Started |
1 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
|
1509 |
Device Collect System Dump Finished |
1 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
|
1510 |
Device Collect System Dump Error |
1 |
1 |
Critical |
1 |
0 |
Device |
Maintenance |
UFM |
|
1511 |
Virtual Port Added |
1 |
0 |
Info |
1 |
0 |
Port |
Fabric Notification |
SM |
|
1512 |
Virtual Port Removed |
0 |
0 |
Warning |
1 |
0 |
Port |
Fabric Notification |
SM |
|
1513 |
Burn Cables Transceivers Started |
0 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
|
1514 |
Burn Cables Transceivers Finished |
0 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
|
1515 |
Burn Cables Transceivers Failed |
0 |
1 |
Warning |
1 |
0 |
Device |
Maintenance |
UFM |
|
1516 |
Activate Cables Transceivers FW Finished |
0 |
0 |
Info |
1 |
0 |
Device |
Maintenance |
UFM |
|
1517 |
Activate Cables Transceivers FW Failed |
0 |
0 |
Warning |
1 |
0 |
Device |
Maintenance |
UFM |
|
1520 |
Aggregation Node Discovery Failed |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1521 |
Job Started |
0 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1522 |
Job Ended |
0 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1523 |
Job Start Failed |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1524 |
Job Error |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1525 |
Trap QP Error |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1526 |
Trap Invalid Request |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1527 |
Trap Sharp Error |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1528 |
Trap QP Alloc timeout |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1529 |
Trap AMKey Violation |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1530 |
Unsupported Trap |
0 |
0 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1531 |
Reservation Updated |
0 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1532 |
Sharp is not Responding |
0 |
1 |
Critical |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1533 |
Agg Node Active |
0 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1534 |
Agg Node Inactive |
0 |
0 |
Warning |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1535 |
Trap AMKey Violation Triggered by AM |
0 |
0 |
Warning |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1536 |
SHARP Reservation Enable Succeeded |
0 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1537 |
SHARP Reservation Enable Failed |
0 |
0 |
Warning |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1538 |
SHARP Reservation Disable Succeeded |
0 |
0 |
Info |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1539 |
SHARP Reservation Disable Failed |
0 |
0 |
Warning |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1540 |
Failed to Assign Guid to Reservation |
0 |
0 |
Warning |
1 |
0 |
SHARP AM |
SHARP |
SHARP |
|
1550 |
Guids Were Added to Pkey |
0 |
0 |
Info |
1 |
0 |
Port |
Fabric Configuration |
UFM |
|
1551 |
Guids Were Removed from Pkey |
0 |
0 |
Info |
1 |
0 |
Port |
Fabric Configuration |
UFM |
|
1552 |
Missing HCAs Assignments to PKey |
1 |
1 |
Warning |
0 |
0 |
Port |
Security |
UFM |
|
1553 |
GUID to Pkey with Index0 |
1 |
1 |
Warning |
0 |
0 |
Port |
Security |
UFM |
|
1554 |
XDR flag disabled |
1 |
0 |
Warning |
0 |
0 |
Site |
Fabric Notification |
SM |
|
1600 |
VS/CC Classes Key Violation |
0 |
0 |
Warning |
1 |
0 |
Port |
Security |
SM |
|
1601 |
Tenant Access Violation |
0 |
0 |
Warning |
1 |
0 |
Port |
Security |
SM |
|
1602 |
PCI Speed Degradation Warning |
1 |
1 |
Critical |
1 |
0 |
Port |
Hardware |
UFM |
|
1603 |
PCI Width Degradation Warning |
1 |
1 |
Critical |
1 |
0 |
Port |
Hardware |
UFM |
|
1604 |
Non-optimal aggregated port bandwidth |
1 |
1 |
Warning |
1 |
0 |
Port |
Hardware |
UFM |
|
1605 |
Routing Engine Action Remove |
1 |
1 |
Warning |
1 |
0 |
Switch |
Fabric Notification |
UFM |
|
1606 |
Routing Engine Action Recover |
1 |
1 |
Info |
1 |
0 |
Switch |
Fabric Notification |
UFM |
|
1607 |
Topology compare Report completed successfully |
1 |
0 |
Info |
0 |
0 |
Site |
Fabric Notification |
UFM |
|
1608 |
Topology compare Report completed with errors |
1 |
1 |
Warning |
0 |
0 |
Site |
Fabric Notification |
UFM |
|
1609 |
In Service Switch Upgrade isolate action |
1 |
1 |
Warning |
1 |
0 |
Switch |
Fabric Notification |
UFM |
|
1610 |
In Service Switch Upgrade deisolate action |
1 |
1 |
Info |
1 |
0 |
Switch |
Fabric Notification |
UFM |
|
1611 |
Different SM configuration values across the fabric |
1 |
0 |
Warning |
0 |
0 |
Site |
Fabric Notification |
UFM |
|
1612 |
Database File is Corrupted |
1 |
1 |
Critical |
0 |
10 |
Grid |
Maintenance |
UFM |
Last updated: