BlueField-2 DPU Firmware Release Notes

Bug Fixes in this Firmware Version


Internal Ref.

Issue

3665350

Description: Fixed an issue on the customized server with an independent power supply, that led to an assert with ext_synd as 0x8ce5 during a power cycle process for virtio.

Keywords: virtio emulation, independent power supply

Discovered in Version:

24.39.2048

Fixed in Release:

24.41.1000

3798733

Description: Fixed an issue that caused traffic not to function properly after performing Live Migration with ingress traffic for vDPA over VFE scenario. 

Keywords: virtio, vDPA over VFE, Live Migration

Discovered in Version:

24.39.2048

Fixed in Release:

24.41.1000

3555832

Description: Fixed an issue that caused traffic failure when modifying the VIRTIO_NET_F_MRG_RXBUF bit for the VDPA device during traffic.

Keywords: VDPA, MRG_RXBUF

Discovered in Version:

24.39.2048

Fixed in Release:

24.41.1000

3771100

Description: Fixed an issue that resulted in the second mkey index returning even if it was not set in the creation of the virtio q when querying virtio q object. 

Keywords: VDPA, virtio, query object

Discovered in Version:

24.39.2048

Fixed in Release:

24.41.1000

3783686

Description: Fixed an issue on the customized server with an independent power supply, that led to a non-functional virtio when power cycled the server during stressful traffic. The following error was provided: "DESTROY_GENERAL_OBJECT(0xa03) No done completion".

Keywords: virtio full emulation, independent power supply

Discovered in Version:

24.39.2048

Fixed in Release:

24.41.1000

3691774

Description: Fixed an issue that resulted in traffic loss after performing Live Migration with virtio vq "frozen-ready" feature.

Note: When the traffic load is high, and the vq frozen-ready cap is on, traffic loss might still be experienced after modifying the vq from suspend to ready mode.

Keywords: VDPA, live migration, virtio, resume

Discovered in Version:

24.39.2048

Fixed in Release:

24.41.1000


Last updated: