Getting Mode of Operation
curl -k -u root:'<PASSWORD>' -X GET https://<bmc_ip>/redfish/v1/Systems/Bluefield/Oem/Nvidia
Current setting appears under Mode.
Setting DPU Mode
-
Run the following Redfish commands:For NVIDIA® BlueField®-3: curl -k -u root:'<PASSWORD>' -H "Content-Type: application/json" -X POST -d '{"Mode":"DpuMode"}' https://<bmc_ip>/redfish/v1/Systems/Bluefield/Oem/Nvidia/Actions/Mode.Set For BlueField-2: curl -k -u root:'' -H "Content-Type: application/json" -X PATCH -d '{"Attributes":{"NicMode":"DpuMode"}}' https:///redfish/v1/Systems/Bluefield/Bios/Settings
-
Reboot the BlueField Arm cores twice.
-
To reboot Arm cores from the Arm OS:
reboot -
To reboot Arm cores from the remote host:
'echo "SW_RESET 1" > /dev/rshim0/misc
-
-
Power cycle BlueField by running the following command from the remote host:
ipmitool chassis power cycle
Setting NIC Mode
-
Run the following Redfish commands:For BlueField-3: curl -k -u root:'<PASSWORD>' -H "Content-Type: application/json" -X POST -d '{"Mode":"NicMode"}' https://<bmc_ip>/redfish/v1/Systems/Bluefield/Oem/Nvidia/Actions/Mode.Set For BlueField-2: curl -k -u root:'' -H "Content-Type: application/json" -X PATCH -d '{"Attributes":{"NicMode":"NicMode"}}' https:///redfish/v1/Systems/Bluefield/Bios/Settings
-
Reboot the BlueField Arm cores twice.
-
To reboot Arm cores from the Arm OS:
reboot -
To reboot Arm cores from the remote host:
'echo "SW_RESET 1" > /dev/rshim0/misc
-
-
Power cycle BlueField by running the following command from the remote host:
ipmitool chassis power cycle
Last updated: