For an archive of bug fixes from previous releases, please refer to Bug Fixes History.
|
Ref # |
Issue |
|---|---|
|
4525138 |
Description: SoC power sensors are not reported via BMC, resulting in missing power telemetry data in ipmitool and WebUI. |
|
Reported in version: 25.04 |
|
|
4484568 |
Description: BMC fails to boot due to |
|
Discovered in version: 24.10 |
|
|
4458182 |
Description: If a corrupted or unauthenticated BFB image is transferred from the BMC to the DPU, the system halts the installation process as part of a built-in security mechanism. Once triggered, the recovery path remains locked to prevent potential compromise. |
|
Discovered in version: 24.10 |
|
|
4484640 |
Description: Certain BMC users fail to authenticate via IPMI lanplus interface (RAKP unauthorized name error). |
|
Discovered in version: 24.10 |
|
|
4517562 |
Description: After upgrading the BMC to version 24.10 or later, SEL entries generated by earlier versions may no longer appear in ipmitool sel output. |
|
Discovered in version: 24.10 |
|
|
4530693 |
Description: Over-temperature warnings in ipmitool SEL logs lack port identifiers and show inconsistent sensor IDs compared to WebUI/Redfish, complicating troubleshooting. |
|
Discovered in version: 24.10 |
Last updated: