Networking NVIDIA BlueField BMC Software

Bug Fixes in This Version


For an archive of bug fixes from previous releases, please refer to Bug Fixes History.

Ref #

Issue

4525138

Description: SoC power sensors are not reported via BMC, resulting in missing power telemetry data in ipmitool and WebUI.

Reported in version: 25.04

4484568

Description: BMC fails to boot due to No Space Left on /var/lib/phosphor-debug-collector/dumps directory, leading to inaccessible BMC.

Discovered in version: 24.10

4458182

Description: If a corrupted or unauthenticated BFB image is transferred from the BMC to the DPU, the system halts the installation process as part of a built-in security mechanism. Once triggered, the recovery path remains locked to prevent potential compromise.

Discovered in version: 24.10

4484640

Description: Certain BMC users fail to authenticate via IPMI lanplus interface (RAKP unauthorized name error).

Discovered in version: 24.10

4517562

Description: After upgrading the BMC to version 24.10 or later, SEL entries generated by earlier versions may no longer appear in ipmitool sel output.

Discovered in version: 24.10

4530693

Description: Over-temperature warnings in ipmitool SEL logs lack port identifiers and show inconsistent sensor IDs compared to WebUI/Redfish, complicating troubleshooting.

Discovered in version: 24.10