This section includes history of bug fixes of 3 major releases back. For older releases history, please refer to the relevant firmware versions Release Notes.
|
Internal Ref. |
Issue |
|---|---|
|
4366117 |
Description: Configuring a small MTU leads to fragmentation of packets critical for the PXE boot process. As a result, the PXE boot filters mistakenly discard these packets, causing the PXE boot to fail. |
|
Keywords: PXE boot filters |
|
|
Discovered in Version: 26.45.1020 |
|
|
Fixed in Release: 26.46.1006 |
|
Internal Ref. |
Issue |
|---|---|
|
4362972 |
Description: Fixed an issue where configuring PHY_RATE_MASK for 10G in NV settings incorrectly disabled 10G capabilities. |
|
Keywords: PHY, 10G |
|
|
Discovered in Version: 26.44.1036 |
|
|
Fixed in Release: 26.45.1020 |
|
|
4199274 |
Description: Fixed an issue where RTT packets with any destination MAC address were incorrectly treated as having a valid destination MAC. The new firmware now discards RTT packets if their destination MAC does not match the port's MAC. |
|
Keywords: RTT, destination MAC |
|
|
Discovered in Version: 26.44.1036 |
|
|
Fixed in Release: 26.45.1020 |
|
Internal Ref. |
Issue |
|---|---|
|
4174552 |
Description: Enabled the get_pf_mac_address function for all available PFs. |
|
Keywords: PF |
|
|
Discovered in Version: 26.42.1000 |
|
|
Fixed in Release: 26.44.1036 |
|
|
4055323 |
Description: Fixed a reference counter issue that resulted in the firmware assertion 0x889f with CQ reference counter underflow to solve a race condition. |
|
Keywords: FW assertion |
|
|
Discovered in Version: 26.42.1000 |
|
|
Fixed in Release: 26.44.1036 |
|
Internal Ref. |
Issue |
|---|---|
|
3961942 |
Description: Fixed an issue that resulted in setup crash when create_sq used invalid mbox. Now the invalid mbox is replaced with a valid DB. |
|
Keywords: mbox |
|
|
Discovered in Version: 26.42.1000 |
|
|
Fixed in Release: 26.43.1014 |
|
|
4040226 |
Description: Added a recovery step in case of CQ doorbell getting lost during VF migration. |
|
Keywords: VF migration |
|
|
Discovered in Version: 26.42.1000 |
|
|
Fixed in Release: 26.43.1014 |
|
|
4014351 |
Description: Fixed the query for FACTORY default NV configuration values. The firmware always returned the "next" value to be applied. |
|
Keywords: Access register MNVDA, QUERY / SET configurations |
|
|
Discovered in Version: 26.42.1000 |
|
|
Fixed in Release: 26.43.1014 |