VF Network Function Limitations in SR-IOV Legacy Mode & in Switchdev Mode
|
Dual Port Device |
Single Port Device |
|---|---|
|
127 VF per PF (254 functions) |
127 |
VF+SF Network Function Limitations in Switchdev Mode
|
Dual Port Device |
Single Port Device |
|---|---|
|
|
|
Internal Ref. |
Issue |
|---|---|
|
4970263 / 4989004 |
Description: A high-temperature assert may be reported only the first time the chip reaches the thermal threshold. |
|
Workaround: N/A |
|
|
Keywords: Temperature |
|
|
Detected in version: 40.49.1014 |
|
|
4893565 / 4532684 |
Description: Occasional high spikes in operation latency may be observed. |
|
Workaround: N/A |
|
|
Keywords: Latency |
|
|
Detected in version: 40.48.1000 |
|
|
5036020 / 5043847 / 5233632 |
Description: For XDR, DC RDMA Read traffic with fewer than 5 QPs may not reach full performance. |
|
Workaround: N/A |
|
|
Keywords: DC RDMA Read traffic |
|
|
Detected in version: 40.49.1014 |
|
|
5234743 / 5145460 |
Description: Query Port Telemetry v2 (CMD 0x14) reports tag 0x20 (rx_los_mask), which should not be populated. |
|
Workaround: N/A |
|
|
Keywords: Query Port Telemetry v2 |
|
|
Detected in version: 40.50.1002 |
|
|
5234750 |
Description: The Plug Voltage sensor does not read the value from the second module. |
|
Workaround: N/A |
|
|
Keywords: Plug Voltage sensor |
|
|
Detected in version: 40.50.1002 |
|
|
5230758 / 4553130 / 5231785 |
Description: For LPO cables, link-up may fail after the port on the peer device is toggled. |
|
Workaround: Toggle the port on the SuperNIC side. |
|
|
Keywords: LPO cables |
|
|
Detected in version: 40.50.1002 |
|
|
5227817 / NVbug 6618275 |
Description: Running applications concurrently on both GPU and CPU with different numbers of QPs, for example 1K QPs on the GPU and 1 QP on the CPU, is not supported when using hardware QoS bandwidth sharing. |
|
Workaround: N/A |
|
|
Keywords: GB300, QoS, GPU, CPU |
|
|
Detected in version: 40.50.1002 |
|
|
5085252 / 5090080 |
Description: Following a hot reset, a false Surprise Link Down (SLD) alarm may be reported intermittently on the Downstream Port (DSP) through the Advanced Error Reporting (AER) register. This is a false alarm and has no functional impact on link stability or data integrity. |
|
Workaround: N/A |
|
|
Keywords: Surprise Link Down (SLD) |
|
|
Detected in version: 40.49.1014 |
|
|
5133249 |
Description: A recent update to the default unmapped local port value causes the LED flow to query an invalid port, resulting in a failure of the LED logic. |
|
Workaround: N/A |
|
|
Keywords: LED indication |
|
|
Detected in version: 40.49.1014 |
|
|
4901395 / 4919262 |
Description: When PXE is enabled for both Legacy (FlexBoot) and UEFI drivers, the UEFI driver supports only a single TFTP session after the DHCP handshake. |
|
Workaround: For scenarios that require multiple concurrent TFTP sessions, disable PXE filters via the HCA HII menu. |
|
|
Keywords: PXE, Filter enabled, UEFI |
|
|
Detected in version: 40.49.1014 |
|
|
5072222 |
Description: In DirectNIC and SocketDirect topologies, PCIe TLP Analyzer visibility is limited to the host’s management domain. Traffic passing through an unmanaged host link, such as a DirectNIC connection to a GPU, is not visible to the local tracer. |
|
Workaround: N/A |
|
|
Keywords: PCIe TLP Analyzer |
|
|
Detected in version: 40.49.1014 |
|
|
4893639 |
Description: Direct Memory Access (DMA) protection is not supported in the ipxe.efi driver. |
|
Workaround: N/A |
|
|
Keywords: DMA |
|
|
Detected in version: 40.48.1000 |
|
|
4835832 |
Description: In rare cases, certain module types may experience link-up failures. |
|
Workaround: Configure the requested speed using the following commands:
|
|
|
Keywords: Cables |
|
|
Detected in version: 40.48.1000 |
|
|
4594515 / 4622127 / NVbug 5460310 |
Description: Running perftest with ib_send_bw using a message size of 4KB and 1000 QPs does not reach the expected full line rate. |
|
Workaround: N/A |
|
|
Keywords: perftest |
|
|
Detected in version: 40.48.1000 |
|
|
4604969 |
Description: Probe packets might be dropped at the transmission stage when multiple congestion control flows are active. |
|
Workaround: N/A |
|
|
Keywords: PCC, RTT, probe |
|
|
Detected in version: 40.47.1026 |
|
|
4496642 |
Description: The timestamps (t2, t4) of the received RTT probes are taken from the free-running clock, even when ROCE_CC_RTT_TIMESTAMP_FORMAT is set to 0x02.
|
|
Workaround: N/A |
|
|
Keywords: RTT RTC timestamp |
|
|
Detected in version: 40.47.1026 |
|
|
4705241 |
Description: When Quantum-2 is part of an XDR topology, serving as a leaf switch connected to NDR-based hosts, a bandwidth degradation of approximately 3–7 Gb/s is expected. |
|
Workaround: N/A |
|
|
Keywords: XDR, NDR, Quantum-2 |
|
|
Detected in version: 40.47.1026 |
|
|
4705948 |
Description: When using DC as the InfiniBand transport type to perform an ib_read RDMA operation between ConnectX-7 (NDR) and ConnectX-8, a bandwidth degradation of approximately 25% may be observed when using a low number of QPs (1–16). The performance degradation diminishes as the number of QPs increases. |
|
Workaround: N/A |
|
|
Keywords: DC, ib_read RDMA, NDR, performance |
|
|
Detected in version: 40.47.1026 |
|
|
4685736 |
Description: Creating a DPA process that allocates a 128 MB data segment and loads a dynamic library may fail with syndrome 0xdc30ac. |
|
Workaround: Limit the DPA application’s data segment size to 64 MB. |
|
|
Keywords: DPA |
|
|
Detected in version: 40.47.1026 |
|
|
4618452 |
Description: When only a partial number of fiber lanes are connected to a module (i.e., not all supported lanes are populated), the module re-insertion process may experience an extended link-up time of approximately one minute. This occurs because the module requires additional time to detect that only a subset of the lanes is connected. |
|
Workaround: N/A |
|
|
Keywords: Cables |
|
|
Detected in version: 40.47.1026 |
|
|
4270913 |
Description: For DC InfiniBand transport, using SRQs requires distributing QPs across four SRQs. Each QP must be assigned to its own SRQ when there are up to four QPs. |
|
Workaround: If more than four QPs are used, they must be evenly distributed across the four available SRQs. |
|
|
Keywords: DC InfiniBand transport, SRQ, QPs |
|
|
Detected in version: 40.47.1026 |
|
|
4665802 |
Description: Due to a re-burst scheduler limitation, the expected “speed of light” value for single QP RDMA Write on ConnectX-8 devices cannot be calculated. Currently, verification is limited to identifying performance degradations relative to previous firmware versions. |
|
Workaround: N/A |
|
|
Keywords: Single QP RDMA Write |
|
|
Detected in version: 40.47.1026 |
|
|
4412310 |
Description: Split operation (port splitting) on the second port is not supported on the ConnectX-8 SuperNIC model 900-9X81Q-00CN-ST0. |
|
Workaround: N/A |
|
|
Keywords: Port splitting |
|
|
Detected in version: 40.45.1020 |
|
|
4394475 |
Description: The existing congestion control configuration applies globally, rather than on a per-priority basis. |
|
Workaround: Ensure that the configuration values for all priorities are aligned in either |
|
|
Keywords: Congestion control, ROCE_CC_PRIO |
|
|
Detected in version: 40.45.1020 |
|
|
4240828 |
Description: Simultaneous access to the same PDDR module info page is not supported. |
|
Workaround: N/A |
|
|
Keywords: PDDR module |
|
|
Detected in version: 40.45.1020 |
|
|
4230775 |
Description: Due to a known issue, telemetry rate must be set to lower than 3 minutes. |
|
Workaround: N/A |
|
|
Keywords: Telemetry rate |
|
|
Detected in version: 40.44.0212 |
|
|
4038325 /
|
Description: Connecting to systems with NRZ speeds of 1,10, 25, 40, 50, or 100Gb/s is not supported. |
|
Workaround: N/A |
|
|
Keywords: NRZ, Connectivity |
|
|
Detected in version: 40.44.0208 |
|
|
4201405 |
Description: Upgrading to firmware 40.44.0xxx from any previous Engineering Sample version requires power cycling the driver and not just resetting it (using mlxfwreset). |
|
Workaround: N/A |
|
|
Keywords: Upgrade, power cycle, reset |
|
|
Detected in version: 40.44.0208 |
Last updated: