Internal Reference Number |
Issues |
|---|---|
|
3343503 |
Description: sharp_am installed from MLNX_OFED uses an invalid range of job IDs, resulting in occasional errors when trying to establish new SHARP jobs. |
|
Workaround: Install sharp_am from HPC-X or UFM instead. |
|
|
Keywords: MLNX_OFED; sharp_am |
|
|
Discovered in Version: 3.2.0 |
|
|
3305335 |
Description: When running mpirun with multiple groups, the following error message might be received:
This message is received due to to the fact that multiple unserialized MAD requests are run in parallel. |
|
Workaround: Set the SHARP_COLL_SERIALIZE_MADS environment variable to TRUE when running mpirun. |
|
|
Keywords: mpirun; SHARP_COLL_SERIALIZE_MADS |
|
|
Discovered in Version: 3.2.0 |
|
|
3336788 |
Description: MAD error responses might be received in libsharp when operating in dynamic trees allocation mode. |
|
Workaround: In case such errors are displayed, disable dynamic trees allocation mode. |
|
|
Keywords: sharp_am; libsharp |
|
|
Discovered in Version: 3.2.0 |
|
|
3225401 |
Description: Dynamic trees creation feature does not support a case in which all root switches are down and restarted. If such a scenario takes place, sharp_am should be restarted once the root switches are up and running. |
|
Workaround: N/A |
|
|
Keywords: Aggregation Manager; sharp_am; dynamic trees |
|
|
Discovered in Version: 3.1.0 |
|
|
3237831 |
Description: SHARP does not support reassignment of LID values.
|
|
Workaround: N/A |
|
|
Keywords: Aggregation Manager; OpenSM |
|
|
Discovered in Version: 3.1.0 |
|
|
3048427 |
Description: In the case that a switch split mode is modified (off/on), sharp_am does not handle the new number of supported ports unless it is restarted. |
|
Workaround: Restart sharp_am after changing a switch split mode definition. |
|
|
Keywords: Aggregation Manager; split mode |
|
|
Discovered in Release: 2.7.0 |
|
|
3051699 |
Description: Changing the configuration of SHARP switch ports using device_configuration_file does not take effect on disconnected split ports. If these ports are connected later, they will remain with their default configuration. |
|
Workaround: If the new configuration is desired for the split ports, make sure to restart the Aggregation Manager after connecting a split port to a host. |
|
|
Keywords: Aggregation Manager; split port |
|
|
Discovered in Release: 2.7.0 |
|
|
3051924 |
Description: Adding or replacing non-leaf switches is currently not supported by Aggregation Manager for tree topologies (Fat-Tree, Quasi-Fat-Tree) and Dragonfly+ topologies. |
|
Workaround: Restart Aggregation Manager after the Subnet Manager completes fabric reconfiguration followed by the fabric changes. |
|
|
Keywords: Fabric extension; Aggregation Manager; AM |
|
|
Discovered in Release: 2.7.0 |
|
|
-
|
Description: On multi PKEY environment, UCX in SHARP can use only the default PKEY (PKEY at index 0). |
|
Workaround: Use sockets for communication over non-default PKEY. |
|
|
Keywords: Configuration, SMX, UCX, PKEY |
|
|
Discovered in Release: 2.4.3 |
|
|
1307124 |
Description: Begin Job requests with virtual ports might be rejected until fabric virtualization info file is parsed. |
|
Workaround: Wait for AM to discover virtual ports before sending Begin Job requests. |
|
|
Keywords: Aggregation Manager, Socket Direct, Virtual Ports |
|
|
Discovered in Release: 1.5.3 |
|
|
1193629 |
Description: Configuring sharpd/sharp_am as daemons is not possible when installing from RPM into non-default location. |
|
Workaround: Configure daemon manually. |
|
|
Keywords: Configuration |
|
|
Discovered in Release: 1.5.3 |
|
|
1307108 |
Description: Discovering a new Aggregation Node (AN) found on the shortest path between two ANs might invalidate the existing path. |
|
Workaround: Restart Aggregation Manager after the Subnet Manager completes fabric reconfiguration followed by the fabric changes. |
|
|
Keywords: Aggregation Manager, Aggregation Node |
|
|
Discovered in Release: 1.5.3 |
|
|
- |
Description: Adding new switches or switch replacement are currently not supported by the Aggregation Manager for Hypercube and Dragonfly+ topologies. |
|
Workaround: Restart Aggregation Manager after the Subnet Manager completes fabric reconfiguration followed by the fabric changes. |
|
|
Keywords: Fabric extension, Aggregation Manager |
|
|
Discovered in Release: 1.5.3 |
|
|
- |
Description: Adding new non-root switches or non-root switch replacement are currently not supported by the Aggregation Manager for tree topologies. (Fat-Tree, Quasi-Fat-Tree) |
|
Workaround: Restart Aggregation Manager after the Subnet Manager completes fabric reconfiguration followed by the fabric changes. |
|
|
Keywords: Fabric extension, Aggregation Manager |
|
|
- |
Description: Aggregation Manager High Availability is currently not supported in HPCX/MLNX OFED packages. Therefore, only a single instance of Aggregation Manager can run in the IB fabric. |
|
Workaround: Use Aggregation Manager in UFM. |
|
|
Keywords: Aggregation Manager |
|
|
- |
Description: Aggregation manager should run on the same Host where the Master Subnet Manager (SM) is running. |
|
Workaround: N/A |
|
|
Keywords: Aggregation Manager |
|
|
- |
Description: In case of HPCX/MLNX OFED packages, upon Subnet Manager handover/failover, another instance of Aggregation Manager should be started on the Host where the new Master SM is running |
|
Workaround: Use Aggregation Manager in UFM. |
|
|
Keywords: Aggregation Manager |
|
|
- |
Description: Aggregation Manager should be started after completion of fabric configuration by the Subnet Manager. |
|
Workaround: N/A |
|
|
Keywords: Aggregation Manager |
|
|
- |
Description: Only Fat-Tree, Quasi-Fat-Tree, Hypercube and Dragonfly+ topologies are supported by the Aggregation Manager. |
|
Workaround: N/A |
|
|
Keywords: Fabric Topology |
|
|
- |
Description: Only IB fabrics where all compute nodes are connected to Mellanox SHARP capable switches (Switch-IB 2) are supported by the Aggregation Manager. |
|
Workaround: Manually configure mapping between the compute port and the Aggregation Node. |
|
|
Keywords: Fabric Topology |
|
|
- |
Description: Upon changes in configuration file beyond parameters in 3.3, Aggregation Manager should be restarted to deploy new configuration. |
|
Workaround: N/A |
|
|
Keywords: Configuration |
Last updated: