5072222

Description: In DirectNIC and SocketDirect topologies, PCIe TLP Analyzer visibility is limited to the host’s management domain. Traffic passing through an unmanaged host link, such as a DirectNIC connection to a GPU, is not visible to the local tracer.

Workaround: N/A

Keywords: PCIe TLP Analyzer

Detected in version:

82.49.1014

4893639

Description: Direct Memory Access (DMA) protection is not supported in the ipxe.efi driver.

Workaround: N/A

Keywords: DMA

Detected in version:

82.49.1014

4835832

Description: In rare cases, certain module types may experience link-up failures.

Workaround: Configure the requested speed using the following commands:

mlxconfig -d <device> set PHY_RATE_MASK_OVERRIDE_P<port>=1
mlxfwreset -d <device> r -y --no_mst
mlxconfig -d <device> set PHY_RATE_MASK_P<port>=<PTYS.speed_mask> (speed mask is defined in PRM)
mlxfwreset -d <device> r -y --no_mst

Keywords: Cables

Detected in version:

82.48.1000

4809493 / 4804815 / 4884845

Description: Running lane margin tests may disrupt traffic, cause connection drops, or degrade performance.

Workaround: 

  1. Disable the drivers before starting the Lane Margin test.

  2. Set an error threshold of 2. 

  3. If the connection drops or performance degrades, re-run the process.

Keywords: Lane Margin

Detected in version:

82.48.1000

4806964 / 4829338 / 4843305 / 4857738

Description: When bringing up 800G_8x on ConnectX-9 with Spectrum-4 switch systems, switch firmware version xx.201.3916-020 or later is required; earlier versions may fail to link up at 800G_8x.

Workaround: N/A

Keywords: Linkup, cables, Spectrum-4, 800G_8x

Detected in version:

82.48.1000