Networking DOCA Platform Framework (DPF) Documentation

Per-DPU BMC Credentials

By default, DPF in Zero Trust mode uses a single shared secret (bmc-shared-password) to authenticate with the BMC on every DPU in a namespace. The per-DPU BMC credentials feature allows each DPUDevice to reference its own secret containing a unique BMC password via DPUDevice.spec.bmcCredentialSecretName. When set, the per-device password takes precedence over the shared one.

How DPF selects the BMC password

DPF resolves the BMC password independently for each DPUDevice:

  • If spec.bmcCredentialSecretName is set, DPF uses the password from that secret for all password-based BMC authentication on that DPU, and the shared password is not used for it (even if the bmc-shared-password secret exists).

  • If spec.bmcCredentialSecretName is not set, DPF falls back to the shared bmc-shared-password secret.

The two modes coexist within a namespace: some DPUs can use per-device credentials while others use the shared password.

Accounts the password is applied to

The resolved password is written to every BMC account DPF manages, so that none of them is left on the BMC factory default:

  • The Redfish user, root on BlueField-3 and admin on BlueField-4.

  • On BlueField-4, the ssh-only service account. BMC firmware that does not expose this account is tolerated: DPF logs the failure and continues.

Since the same password is applied to both accounts on BlueField-4, it must satisfy the account policy of both — in particular the BMC's minimum password length of 13 characters. A rejected password fails with an error naming the account and quoting the BMC's own reason, and is reported as BMCCredentialsReady=False with reason BMCAuthenticationFailed.

This hardening runs right after the BMC factory reset performed while the DPUDevice is initialized, which returns every account to the factory default password.

Onboarding modes and the shared password

How a DPU first obtains its credential depends on how its DPUDevice is created.

Auto-discovery (DPUDiscovery)

When DPUDiscovery scans a BMC IP range, it authenticates to each BMC using the shared bmc-shared-password secret and creates a DPUDevice without spec.bmcCredentialSecretName. DPUs onboarded this way therefore start on the shared password. To move such a DPU to a unique password afterwards, set spec.bmcCredentialSecretName; DPF treats this as a rotation from the shared password to the per-device one.

Because the discovery crawler always authenticates with the shared password, the bmc-shared-password secret is required whenever DPUDiscovery is used.

Declarative creation

If you create the DPUDevice yourself with both spec.bmcIp and spec.bmcCredentialSecretName set before discovery reaches that BMC, DPF authenticates to the BMC directly with the per-device password (changing it from the BMC default if necessary). In this case the shared password is not used for that DPU. DPUDiscovery skips any BMC IP that already belongs to a DPUDevice, so a pre-declared device is not overridden.

Creating a Per-DPU Credential secret

Create a Kubernetes secret in the same namespace as the DPUDevice. The secret must contain a password key with the BMC credential value and should be created with immutable: true.

YAML
apiVersion: v1
kind: Secret
metadata:
  name: my-dpu-bmc-v1
  namespace: dpf-operator-system
type: Opaque
immutable: true
stringData:
  password: <bmc-password>

If the secret is not created with immutable: true, DPF sets it to immutable after reading the password. This enforces the rotation model where a new secret with a different name is required for password changes.

Assigning a Credential to a DPUDevice

Set spec.bmcCredentialSecretName on the DPUDevice to the name of the secret:

YAML
apiVersion: provisioning.dpu.nvidia.com/v1alpha1
kind: DPUDevice
metadata:
  name: my-dpu
  namespace: dpf-operator-system
spec:
  bmcCredentialSecretName: my-dpu-bmc-v1
  bmcIp: 10.0.110.122

When this field is set, DPF uses the password from the referenced secret for all BMC authentication operations on that DPU. If the field is not set, DPF falls back to the shared bmc-shared-password secret.

A per-device credential secret must be referenced by only one DPUDevice. Sharing the same bmcCredentialSecretName across devices is not allowed. If a second DPUDevice references a secret that is already in use, DPF sets BMCCredentialsReady=False with reason SharedCredentialSecretNotAllowed on that device and does not use the credential. A device that already adopted the secret in status keeps working. The blocked device is requeued periodically and recovers once the conflicting reference is removed. The shared bmc-shared-password secret is the only credential that may be used by multiple devices.

[!NOTE] When bmcCredentialSecretName is set but the secret is missing or invalid, DPF reports an error rather than falling back to the shared password.

Password Rotation

To rotate a DPU's BMC password:

  1. Create a new immutable secret with a different name containing the new password (see Creating a Per-DPU Credential secret).

  2. Update spec.bmcCredentialSecretName on the DPUDevice to reference the new secret.

  3. DPF detects that spec.bmcCredentialSecretName differs from status.bmcCredentialSecretName, authenticates to the BMC and updates the password to the new one.

  4. Wait for status.bmcCredentialSecretName to match the spec value, then delete the old secret.

DPF places a finalizer on the active credential secret, so deletion is blocked until the controller has finished the rotation and moved to the new secret. See Secret Protection for details.

Mode Switching

Shared to Per-Device (Allowed)

Setting spec.bmcCredentialSecretName on a DPUDevice that was previously using the shared password is treated as a password rotation from the shared password to the per-device one.

Per-Device to Shared (Not Allowed)

Switching from a per-device credential back to shared mode is not allowed. If the DPUDevice status shows a per-device credential and the spec is changed to remove bmcCredentialSecretName (or set it to bmc-shared-password), DPF sets BMCCredentialsReady=False with reason ModeSwitchNotAllowed and does not perform any BMC operations.

To return to shared mode, delete the DPUDevice and recreate it without bmcCredentialSecretName.

Monitoring Credential Health

The DPUDevice reports credential status through the BMCCredentialsReady condition:

Condition

Reason

Meaning

BMCCredentialsReady=True

Success

Credential secret is valid and authentication succeeded

BMCCredentialsReady=False

CredentialsSecretNotFound

The referenced secret does not exist

BMCCredentialsReady=False

CredentialsSecretInvalid

The secret exists but is malformed (missing or empty password key)

BMCCredentialsReady=False

BMCAuthenticationFailed

The password was rejected by the BMC

BMCCredentialsReady=False

ModeSwitchNotAllowed

Attempted to switch from per-device to shared mode

BMCCredentialsReady=False

SharedCredentialSecretNotAllowed

Device references a per-device secret already used by another DPUDevice

Check the BMCCredentialsReady condition on the DPUDevice status to diagnose issues.

Secret Protection

DPF adds a finalizer (provisioning.dpu.nvidia.com/bmc-credential) to per-device credential secrets to prevent accidental deletion while a DPUDevice depends on them. The finalizer is automatically removed when:

  • The DPUDevice is deleted.

  • The credential is rotated to a new secret (the finalizer moves from the old secret to the new one).

Limitations

  • Each per-device credential secret (spec.bmcCredentialSecretName) can be used by only one DPUDevice. A device that shares a secret already adopted by another device is rejected with SharedCredentialSecretNotAllowed; the established owner keeps working. Only bmc-shared-password may be shared.

  • The shared bmc-shared-password secret cannot currently be globally disabled. It remains the credential used by DPUDiscovery and the fallback for any DPUDevice without spec.bmcCredentialSecretName. Per-device credentials are an override applied per DPUDevice, not a cluster-wide replacement of the shared password.

  • Auto-discovery (DPUDiscovery) cannot onboard a DPU directly onto a unique password; discovered DPUs start on the shared password. They can keep using it, or be rotated to a per-device credential afterwards. Onboarding directly with a unique password is only possible through declarative creation.