Kubernetes API Server Access

In Zero Trust mode, DPFOperatorConfig.spec.overrides.kubernetesAPIServerVIP and DPFOperatorConfig.spec.overrides.kubernetesAPIServerPort are required. Set them to the Kubernetes API server endpoint of the DPF cluster.

DPU Discovery and DPUNode and DPUDevice Object Creation

DPF provides two approaches for discovering and creating DPU resources:

  1. Automated Discovery: Using DPUDiscovery to automatically scan for DPUs and create DPUDevice and DPUNode resources.

  2. Manual Creation: Manually creating DPUDevice and DPUNode resources for each DPU.

You can choose either approach based on your deployment requirements. Automated discovery is recommended for larger deployments, while manual creation provides more control for smaller or specific configurations.

Automated DPU Discovery

DPUDiscovery enables automatic discovery of DPU devices and nodes by scanning specified IP ranges. This approach automatically creates DPUDevice and DPUNode resources for any discovered DPUs.

1. First, create a YAML file for the DPUDiscovery resource. Let's call it dpudiscovery.yaml:

YAML
apiVersion: provisioning.dpu.nvidia.com/v1alpha1
kind: DPUDiscovery
metadata:
  name: dpu-discovery-192.168.1-10
  namespace: dpf-operator-system
spec:
  # Define the IP range to scan
  ipRangeSpec:
    ipRange:
      startIP: "10.0.110.120"    # Replace with your start IP
      endIP: "10.0.110.125"     # Replace with your end IP

  # Optional: Set scan interval
  scanInterval: "3m"
  # Optional: Set number of workers (default is 1 per 255 IPs)
  workers: 1

2. Apply the resource using kubectl:

Bash
kubectl apply -f dpudiscovery.yaml

3. Check the status of the crawler:

Bash
kubectl get dpudiscovery dpu-discovery-192.168.1-10 -o yaml

The DPU discovery will:

  1. Start scanning the specified IP range

  2. Create DPUDevice and DPUNode* resources for any discovered DPUs

  3. Continue scanning at the specified interval

  4. Update its status with the last scan time and found DPUs

You can monitor the discovered DPUs with:

Bash
# List discovered DPU devices
kubectl get dpudevices

# List discovered DPU nodes
kubectl get dpunodes

* DPUDiscovery will skip the creation of a DPUNode if there is an existing one with the spec.dpus field containing the DPUDevices serial number.

Limitations

  • When using autodiscovery for DPUNodes, the created DPUNodes will be named after dpunode-<DPU_SERIAL_NUMBER>. In case the HBN DPUService is used in conjuction with this DPU provisioning mode, the HBN configuration needs to be adjusted to match the discovered nodes accordingly.

Manual DPU Resource Creation

If you prefer to manually create DPU resources or need more control over the creation process, you can create DPUDevice and DPUNode resources manually.

Creating DPUDevice manually

Create a DPUDevice resource for each DPU:

The DPUDevice is immutable, and creating a DPUDevice will not trigger DPU provisioning.

YAML
---
apiVersion: provisioning.dpu.nvidia.com/v1alpha1
kind: DPUDevice 
metadata:
  name: dpu-device-1
  namespace: dpf-operator-system
spec:
    bmcIp: 10.0.110.122

Creating a DPUNode manually

Create a DPUNode resource for each host that has a DPU:

The .spec.dpus field contains the names of each DPUDevice attached to the node.

YAML
---
apiVersion: provisioning.dpu.nvidia.com/v1alpha1
kind: DPUNode
metadata:
  labels:
    feature.node.kubernetes.io/dpu-enabled: "true"
  name: worker1
  namespace: dpf-operator-system
spec:
  dpus:
  - name: dpu-device-1
  nodeRebootMethod:
    external: {}

Secure Boot

DPF supports configuring UEFI Secure Boot on DPUs during Zero Trust provisioning. When secureBoot is set in the DPUDeployment (or DPUSet), the controller detects the current hardware state via the BMC and configures it automatically, performing the required ARM force restarts.

For configuration details, mode-specific behavior, and the impact of changing this setting on existing DPUs, see Secure Boot.

For more information on BlueField Secure Boot, see Secure Boot in the NVIDIA documentation.

BMC mTLS Server Certificate Rotation

In Zero Trust mode the provisioning controller talks to each DPU BMC over the Redfish API using mTLS. During provisioning the controller bootstraps mTLS on the BMC: it installs the DPF CA, requests a BMC server certificate through cert-manager, replaces the BMC's server certificate, and enables mTLS. From that point the controller connects to the BMC with full certificate verification (it validates the BMC server certificate against the DPF CA and pins the BMC IP), so the served server certificate must stay valid for the lifetime of the DPU.

The BMC server certificate is issued for 365 days. To avoid expiry the provisioning controller automatically rotates it before it expires.

Automatic rotation

  • Each DPUDevice tracks its BMC server certificate under status.bmcServerCertificate:

    • notAfter — the expiry of the currently installed BMC server certificate.

    • lastRotationTime — when the controller last rotated the certificate.

    • observedManualTrigger — the last manual-rotation token the controller has already processed (see Manual rotation).

  • The controller renews the certificate once it enters the renewal window, which defaults to 30 days before expiry. This window is configurable cluster-wide via DPFOperatorConfig.spec.provisioningController.bmcServerCertRenewBefore (see Provisioning Controller Configuration Options).

  • For DPUs that were provisioned before this feature existed, the controller backfills notAfter by reading the certificate the BMC is currently serving, rather than forcing an immediate fleet-wide rotation.

  • Rotation progress is reported through the BMCServerCertificateReady condition on the DPUDevice:

Condition status

Reason

Meaning

True

Success

The certificate is installed and outside the renewal window.

False

BMCServerCertificateRotating

A rotation is in progress (a new CSR was generated and the cert-manager CertificateRequest is being issued).

False

BMCServerCertificateRotationFailed

The last rotation attempt failed; the controller retries automatically.

No user action is required for automatic rotation.

Manual rotation

You can force an immediate rotation of a single DPU's BMC server certificate by annotating the DPUDevice with provisioning.dpu.nvidia.com/rotate-bmc-server-certificate. The annotation value is an opaque token — any non-empty string (a timestamp or UUID is recommended). Rotation runs whenever the annotation value differs from status.bmcServerCertificate.observedManualTrigger; after a successful rotation the controller copies the value into observedManualTrigger, so the same token is never processed twice.

Bash
kubectl -n dpf-operator-system annotate dpudevice $DPUDEVICE_NAME \
  provisioning.dpu.nvidia.com/rotate-bmc-server-certificate="$(date +%s)" --overwrite

Watch the rotation complete:

Bash
kubectl -n dpf-operator-system get dpudevice $DPUDEVICE_NAME \
  -o jsonpath='{range .status.conditions[?(@.type=="BMCServerCertificateReady")]}{.status}{"\t"}{.reason}{"\n"}{end}'

Expired certificate recovery

Manual rotation requires the provisioning controller to connect to the BMC with mTLS. If the BMC server certificate has already expired, or otherwise no longer verifies against the trusted CA, the controller cannot open the mTLS connection needed to request and install a new certificate. In this case the controller reports BMCServerCertificateReady=False with reason BMCServerCertificateRotationFailed.

DPF does not automatically re-run bootstrap when this happens because bootstrap uses basic-auth access to the BMC. To recover, delete and recreate the affected DPUDevice so DPF performs the mTLS bootstrap flow again and installs a fresh BMC server certificate.

Bash
kubectl -n dpf-operator-system delete dpudevice $DPUDEVICE_NAME

SPIFFE Workload Identity

In Zero Trust mode the DPU Agent can authenticate to the management-cluster Kubernetes API server with a SPIRE-issued JWT-SVID instead of a kubeadm bootstrap token, and DPUServices can opt in to their own per-DPU SPIRE identities. Both are opt-in through DPFOperatorConfig.spec.security.spiffe and DPUService.spec.security.spiffe, and require a pre-installed SPIRE deployment.

For the prerequisite contract, configuration, verification and troubleshooting, see SPIFFE Workload Identity.

External Host Reboot

In the Zero Trust scenario, DPF cannot manage the DPU's host machine, so the host reboot must be performed manually by the user (or by external automation) during the DPU provisioning process.

DPF signals that a manual reboot is required by setting the provisioning.dpu.nvidia.com/dpunode-external-reboot-required: "true" annotation on the DPUNode (equivalently, the DPU reports status.rebootStatus.reason: WaitingForManualPowerCycleOrReboot). Only once this annotation is present, perform the requested operation promptly, and after the node boots up remove the annotation. If the reboot is delayed too long, the DPU join cluster's secret expires and the DPU CR remains pending in the DPU Cluster Config phase.

The host operation to perform is the one DPF requests in DPUNode.status.rebootMethod -- see DPUNode: Aggregated reboot method for what each value requires. The field is empty until at least one of the node's DPUs reaches the Rebooting phase, so read it only after the annotation above appears.

Bash
kubectl -n dpf-operator-system get dpunode -o custom-columns='NAME:.metadata.name,REBOOT_METHOD:.status.rebootMethod'

Manual action is only needed for nodeRebootMethod: external. On the script path the DPU reports RebootScriptWaiting instead of WaitingForManualPowerCycleOrReboot, and DPF runs the Job built from the script you supply -- see DPUNode: Script reboot job failures and recovery for how Jobs, DPU phase DPURebooting, and recovery interact.

Service Readiness

Because DPF does not manage the host in Zero Trust, the host may finish booting before the DPU is ready to serve its traffic. DPF can close that gap by having the DPU firmware hold the host at the start of its OS initialization and release it only once a chosen DPU readiness gate is met.

This is configured through a DPUFlavor and requires a host power cycle to take effect. The hold is best effort and depends on host BIOS configuration that DPF cannot see, so read Service Readiness before relying on it for boot ordering.